ASPE ULTRA AUTOMATED SOLID PHASE EXTRACTION SYSTEM

ASPE Ultra series Automated Solid Phase System is an automated sample preparation system designed for analysis of organic substances in water samples, including drinking water, tap water, underground water, surface water as well as wastewater. RayKol ASPE Ultra automate liquid liquid extraction equipment can be used in the purification and enrichment of target compounds in water samples before analytical instrumentation, it automatically completes the steps of filtering, conditioning, loading, rinsing, drying, eluting and concentration, fully unattended extraction, avoiding exposure of hazardous chemicals to lab technicians, easy to build up a smart and safe laboratory environment.

ASPE ULTRA AUTOMATED SOLID PHASE EXTRACTIONSYSTEM FEATURES

Fully automatically preprocess water samples before analytical instrumentation

Good parallelism and reproducibility by independent pump-valve system and stable flow rate control

Avoid environmental interferences by a light-proof hood and airtight cavity design

Higly compatible with various applications, disk and column automated solid phase extraction available

Real-time monitoring, easy to access anytime

ASPE ULTRA AUTOMATED SOLID PHASE EXTRACTION SYSTEM SPECIFICATIONS

Parameter

Specification

Product

ASPE Ultra 06

ASPE Ultra 08

Extraction channel

6

8

SPE disks

25mm, 47mm

25mm, 47mm

SPE cartridges

3mL, 6mL, 12mL

3mL, 6mL, 12mL

Solvent capacity

7

7

SPE column drying

Vacuum;

Vacuum;

nitrogen gas purge+vacuum

nitrogen gas purge+vacuum

Material contact with solvents

Teflon, glass

Teflon, glass

Waste discharge channel

3

3

(water sample waste; organic waste; organic waste contain fluorine)

(water sample waste; organic waste; organic waste contain fluorine)

Software interface

Built-in screen control

Built-in screen control

Dimension

66cm x 58cm x 76cm

66cm x 58cm x 76cm

Weight

50kg

50kg

Power supply

200 to 240V, 50/60Hz

200 to 240V, 50/60Hz

Power rate

450W

450W

Storage temperature

0 to 40°C

0 to 40°C

Storage humidity

20 to 85%

20 to 85%

Operating temperature

10 to 40°C

10 to 40°C

Operating humidity

20 to 80%

20 to 80%

ASPE ULTRA AUTOMATED SOLID PHASE EXTRACTION SYSTEM APPLICATIONS

ASPE Ultra Automated Solid Phase Extraction System targets in trace organic compounds in all kinds of water, can be mainly applied in the fields and industries of:

✔ Disease control

✔ Environmental monitoring

✔ Municipal water

✔ Geology and mining

✔ Acadamic

✔ Hydrology

TYPES OF ANALYSIS USING ASPE ULTRA AUTOMATED SOLID PHASE EXTRACTION SYSTEM

Environmental sanitation - Standards for drinking water quality

Standard examination methods for drinking water

Environmental quality standard for atmosphere, water and soil - Ground water

Environmental quality standard for atmosphere, water and soil - Surface water

Standard of water quality examination methods for urban water supply

Urban water supply - Determination of stibium

Urban water supply - Determination of sodium, magnesium, calcium - Ion chromatography method

Urban water supply - Determination of organic phosphorous pesticides - GC method

Urban water supply - Determination of volatile organic compounds

We can offer kinds of total laboratory automation systemfor sale, if you have needs lab automationsystem, please contact us.


Send product request

To: Raykol Group(XiaMen)Corp.,Ltd.
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

RAYKOL AUTOMATED LAB SYSTEMS
RAYKOL AUTOMATED LAB SYSTEMS RayKol Group is dedicated to research&development and manufacture of automated laboratory systems. With systematic framework and integrated dev...
MPE AUTOMATED VACUUM PARALLEL EVAPORATOR
MPE AUTOMATED VACUUM PARALLEL EVAPORATOR Raykol MPE High-throughput vacuum evaporatoris a new automated evaporation system integrated the benefits of conventional rotary evaporation and hi...
AUTO GDA SERIES AUTOMATED GRAPHITE DIGESTION SYSTEM
AUTO GDA SERIES AUTOMATED GRAPHITE DIGESTION SYSTEM Raykol Auto GDA series Automated graphite digestersystem is designed based on wet digestion theory, it can automatically complete full digestion pr...
QUECHERS EXTRACTION
QUECHERS EXTRACTION As testing technology and method for food safety is developed and improved, QuEChERSmethod has become one of common sample preparation techniques t...
LIQUID WASTE COLLECTION CONTAINER
LIQUID WASTE COLLECTION CONTAINER Volatile hazardous vapor of chemical waste discharged from laboratory instruments can easily contaminate laboratory environment, it would cause ser...
All supplier products

Same products

Cold Glaze Stabilizer (Glazemate)
Cold Glaze Stabilizer (Glazemate) Seller: Marine Hydrocolloids Meron’s Cold Glaze Stabilizer Glazemate, a ready to use Neutral Cold Glaze Stabiliser, whic...
Pectin
Pectin Seller: Marine Hydrocolloids Meron Pectin is a structural polysaccharide of the cell wall of plants, Commercial pectin is comm...
Milk Shake Stabilizer
Milk Shake Stabilizer Seller: Marine Hydrocolloids Meron’s Milk Shake StabilizerOur Milkshake Stabilizer has been designed to provide creamy m...
Flavoured Milk Stabilizer
Flavoured Milk Stabilizer Seller: Marine Hydrocolloids Meron’s Flavoured Milk StabilizerFlavoured milk drinks are sweetened dairy drinks, typicall...
Ice Cream Stabilizer
Ice Cream Stabilizer Seller: Marine Hydrocolloids Meron’s IceCream Stabilizer is a 100% vegan blend developed to not only enhance the texture...