SF6 reference Capacitor - 400kV 50pF compressed gas standard capacitor
Genneal Information:
Compressed air standard capacitor is a necessary instrument in every HV test lab. It is used to measure the capacitance of capacitor, cable, sleeve, insulator, transformer winding, and insulating material, as well as tanδ of dielectric loss. At the same time, it can also be used as HV capacitor for pressure sharing device of HV measuring capacitor. Under certain condition, it can be used as HV coupling capacitor during partial discharge measurement.
Performance
Standard capacitor is used as comparison reference, which is assorted to precise measurement to inductance value, loss, capacitance, and dielectric loss value of HV equipment such as reactor,cable, transformer, sleeve, and capacitors etc. The standard capacitor is equipped with HV pole which can be connected with other HV parts in HV measuring circuit without partial discharge.
Standard capacitor is designed for indoor application, movable.
For extra high voltage, discrete capacitor grading is used to realize linear distribution of electric field,
so as to maintain an ambient humidity above 95% (without condensate water). Standard capacitor
has high voltage endurance and extremely stable humidity and voltage factor.
Specification :
- 50 pF capacity, 400 kV nominal tension, SF6 insulated, electrodes to avoid corona that meets thefollowing specifications.
- Tangent delta: <10-5
- Changes in capacity between 0% and 100% voltage: <5*10-5
- Stability in time: 0.01% / year.
- Temperature variation: 3 X 10 -5 K-1
- Pressure variation: <1% / year
- Frequency variation between 50 Hz and 1 kHz: <10-5
- Partial discharge <5 pC
Tests
- Accuracy of the calibration at its rated operating range: Primary voltage: from 0% to 100% Vn.
- Testing frequency supported at industrial power frequency.
Structure:
Ø Insulation sleeve and steel sheet made bottom and cover for casing. Bottom and cover are
fastened on both sides of insulation sleeve with stainless bolts and rings;
Ø Shielding case of capacitor is made of stainless pipe;
Ø HV/LV poles of capacitor is coaxial pole;
Ø Capacitor is equipped with pressure gauge and vent valve.
Ø Capacitor is filled with SF6. Pressure is 450±50kPa at 20 ℃.
Ø Capacitor frame is installed with universal wheel.
Ø External shielding plug socket of capacitor is adaptable to all kinds of bridge plugs
home/abroad.
Application conditions:
- RH: <80%
- Ambient T: -5~+40℃
- Altitude: <1000 m
- Rated voltage 400kV
- Withstand voltage: 440kV
- Rated frequency: 50Hz
- Capacitance: 50pF
- Capacitance stability: 0.01%/%/year
- Capacitance value accuracy: <5*10-5
- SF6 working pressure: 450±50KPa
- Capacitor tanδ: <1X10-5
- Capacitance pressure factor absolute value: ≤2.2×10-3/0.1Mpa
- Capacitance voltage factor absolute value: ≤3×10-5
- Capacitance temperature factor absolute value: ≤3×10-5/℃
- Capacitor shall bear 2Xrated air pressure test/72h.
- Sealing: ≤1% leakage rate/y
- Electric safety protection: LV pole overpotential protection
- Gas standard capacitor installation dimension:
- Base plate: 1650mm*1650
- Height: 3600mm
- Weight: <980kg
Complete supply:
- Standard capacitor: 1set
- Exclusive grading ring: 1piece
- Exclusive measuring cable: 1piece
- Junction box: 1piece
- Factory inspection report: 1copy
- Certificate: 1copy
- Technical manual: 2copies
- 0.05% measurement bridge 1 set
Send product request
Other supplier products
| HV Large Capacity Testing Station design | HV Large Capacity Testing Station design We will be willing to provide whole-process engineering consulting servicesfor you: Preparingfeasibility s... | |
| DC voltage test system | DC voltage test system DC test systems are used to test components and complete systems found in electrical power supply systems and operating on D... | |
| Energy meter calibration -- CNKP-S3000 Three phase 5 position 0.05% Accuracy 0-120A | Energy meter calibration -- CNKP-S3000 Three phase 5 position 0.05% Accuracy 0-120A KP-S3000 three phase energy meter test bench is a new generati... | |
| Shielding hall of HV PD test | Shielding hall of HV PD test Application: HV test shielding room (faraday cage) areWidely used in power cable, transformer, transformer switch, tra... | |
| Partial Discharge Testing Detector Testing instrument | Partial Discharge Testing Detector Testing instrument RequestedService Condition: Ambient temperature:0~20℃±2℃ Relative humidity:≤80% Po... |
Same products
| High-purity silica nano powder | Seller: Hebei Guiyan Electronic Materials CO., Ltd | High-purity silica nano powder High-purity silica nanopowderis a nano-silica powder prepared via... | |
| High purity organic colloidal Silica | Seller: Hebei Guiyan Electronic Materials CO., Ltd | High purity organic colloidal Silica High-purity organic silica solis manufactured from high-pur... | |
| Ultra high purity Silica Sol | Seller: Hebei Guiyan Electronic Materials CO., Ltd | Ultra high purity Silica Sol Ultra-high purity silica solis manufactured from ultra-high purity ... | |
| Silicate Ester | Seller: Hebei Guiyan Electronic Materials CO., Ltd | Silicate Ester By directly reacting high-purity silicon powder with alcohols under the action of... | |
| Body-Worn Camera | Seller: Shenzhen Tianlong Century Technology Development CO., LTD | Body-Worn Camera The Body-Worn Camerais a portable audio and video recording device that enhance... |