WDet-5000 Ammonia-Nitrogen Online Automatic Analyzer
HANGZHOU ZETIAN TECHNOLOGY CO., LTD was established in 2008, and has national wide impact in China now as a fast-growing company specialized in environmental pollution monitoring and industrial process control. Our instruments and emission analyzers can be customized by our professional staff who understand your compliance testing needs and provide you best solutions. We focus on Ultra-violet DOAS gas analyzer, Laser TDLAS gas analyzer, continuous emission monitoring system, air quality monitor, water quality testing, etc, basically covering air pollution monitoring, metallurgical industries, chemical, refinery industries, cement, sulfur recovery, flue gas and other online monitoring needs. Our friendly and professional staff are always ready to provide technical support to our customers.
ammonia analyzer wastewater
Overview Of WDet-5000 Ammonia-Nitrogen Online Automatic Analyzer Wastewater
WDet-5000 is a self-developed ammonia-nitrogen online monitoring analyzer wastewater, based on the global initiative magnetic conductivity measurement platform, combining with constant optical fiber and digestion colorimetric integration technology. The ammonia-nitrogen automatic online monitoring analyzer wastewater has the features, including high precision, low detection limit, high stability and low maintenance frequency.
This ammonia analyzer wastewaterworks in accordance with the technical requirements of HJ/T 536-2009 ammoniacal nitrogen water qualityMeasurement-Salicylic Acid Method, fully meets the pollution sources, municipal wastewater, industrial processes in the application areas, and has passed the certification of CMC and CCEP.
Features Of WDet-5000 Ammonia-Nitrogen Online Automatic Analyzer Wastewater
High accuracy and reliability, strong capability of anti-interference
- Magnetic conductivity measurement technology used on the ammonia-nitrogen analyzer wastewater will be not affected by chromaticity, suspended solids, and bubbles, especially suitable for the monitoring of inlet water
- The ammonia-nitrogen analyzer wastewater has a special design of flow and reagent ratio, high precision, low detection limit(0.01mg/L)
- The ammonia-nitrogen analyzer wastewater adopts constant optical fiber and light intensity compensation algorithm, small drift for long-term operation
Low maintenance and cost
- The ammonia-nitrogen analyzer wastewater has a key self-check function, easy to debug, maintain, comparison test
- The ammonia-nitrogen analyzer wastewater has a self-diagnosis function, assisting maintainer to analyze the failure
- This type of water analyzer instrument importes single-channel high integration valve island which is simple and easy to maintain, dismantle and clean
- The ammonia-nitrogen analyzer wastewater has all-day networking for real-time inspection of instrument running state
High intelligent level
- Scan code function: rapidly obtain running/maintenance information of the the ammonia-nitrogen analyzer wastewater
- Alarm function: the ammonia-nitrogen analyzer wastewater provides intuitive and accurate information for grounding self-check, reagent insufficiency and etc
- Quality control: the ammonia-nitrogen analyzer wastewater is equipped with a parallel sample test, standard sample verification, and standard recovery rate detection
- Reverse control function: the ammonia-nitrogen analyzer wastewater starts automatically by flow and PH
Technical Specification Of WDet-5000 Ammonia-Nitrogen Online Automatic Analyzer Wastewater
Method |
Water Quality Ammonia-Nitrogen Measurement-Salicylic Acid Method |
Range |
|
Zero Drift |
<0.02mg/L |
Span Drift |
<1% |
Indication Error |
±10% |
Repeatability |
≤3% |
Memory Effect |
20%F.S. ±0.3mg/L |
80% F.S. ±0.2mg/L |
|
Interval |
Hourly and interval measurement, and the instrument can also be started by serial port |
Maintenance |
<2 hour/month |
Quantitative Lower Limit |
|
Quality Control Sample Comparison |
±10% |
Water Sample Comparison |
>2mg/L±10% ≤2mg/L±0.2mg/L |
Reagent |
1 set reagents is able for about 250 times of measurement (can be customized according to field needs) |
External Interface |
1×4-20mA input/output (expandable to 2 ) RS485/RS232/USB interface/WIFI/ Bluetooth (optional) |
Working Temp |
5℃~40℃ |
Power |
200W (220VAC 50Hz), regardless of the pump |
在线联系供应商
Other supplier products
HM-200 Hygronom | Overview Hygronom is used to measure the humidity of flue gas emitted by pollution sources. According to measured humidity, it converts wet gas con... | |
DPM-6000 PM Monitor PM2.5/PM10 | Overview Of DPM-6000 PM Measuring Devices Inhalable particle content is one of the most important indexes for measuring air quality. Combining year... | |
MDet-5000X Colorimetric Method Heavy Metal Online Analyzer | Overview Heavy metal pollution refers to the environmental pollution caused by heavy metals or their compounds, which mainly caused by human factor... | |
WDet-5000UVI Immersion UV Water Analyzer | HANGZHOU ZETIAN TECHNOLOGY CO., LTD was established in 2008, and has national wide impact in China now as a fast-growing company specialized in env... | |
HM-100 High-temperature Hygronom | Overview Hygronom is also called gas moisture meteror dew-point meter, which is used to measure the humidity of flue gas emitted by pollution sourc... |
Same products
flask | 卖方: PakGent Bioscience (Suzhou) Co., Ltd. | Fit tips, DNase/RNase free, sterile, rack pack(78mm) PakGent UFPT-1000R-L Low Retention 1000ul M... | |
Lesinurad | 卖方: Lepu Medical Technology(Beijing)Co.,Ltd | Lesinurad *Product registration and availability vary by country. For more information on prod... | |
LEN503 Nebulizer | 卖方: Lepu Medical Technology(Beijing)Co.,Ltd | Cute pet caring Small atomized particles nebulizer machine for kids Adjustable atomizing cup H... | |
SINOART Shanghai Co., Ltd. | 卖方: SINOART Shanghai Co., Ltd. | SINOART specializes in a series of easels, artist canvas, produced by Jinhua GOWIN and PAN’... | |
High Voltage Surge Arresters | 卖方: Guangdong Yufeng Industries Co.,Ltd | High voltage surge arresters, also called lightning arresters, are electrical devices designed to... |