ACDC Hybrid Solar Air Conditioner ( On Grid Working )

Convenient and quick installation, no longer require a solar controller, battery, and inverter

Hybrid Solar Air Conditioner Overview

Cooling capacity 9000BTU/12000BTU/18000BTU/24000BTUInside building digital calculator to priority biggest using DC power, auto balance 220V city grid power. DC input range is DC50V~DC300V, so can connect max around 1500W solar PV panel Max consumption 90% solar DC power.

This solar thermal hybrid air conditioner no need battery, install take small place, so for the end user whole system running cost is very low.

When night, it can same as normal inverter air conditioner by city power 220V.

ACDC On-grid solar split air conditioner wall split type, the power from solar panel priority supply directly to indoor&outdoor fan motor and compressor. When the solar power is not sufficient, by equipped with dual PV MPPT tracking system, the system automatically switches to run by grid power, thus achieved the AC/DC power supply interaction, and uninterrupted supply power to air conditioner, ensure the system high efficiency up to SEER36, high quality with 3-5 years warranty, convenient installation, wide voltage design, free combination of solar panels.

The air conditioner directly connects solar PV panel to AC unit by MC4 solar connectors, others like normal split air conditioners.

System Advantages:

Hybrid Solar Air Conditioning System Specification

SpecificationofWall-mountedType

Model

ACDC09-SBP

ACDC12-SBP

ACDC18-SBP

ACDC24-SBP

Powersupply

PH-V-HZ

1Ph,220-240V~,50/60Hz

1Ph,220-240V~,50/60Hz

1Ph,220-240V~,50/60Hz

1Ph,220-240V~,50/60Hz

V

DC50-380V

DC50-380V

DC50-380V

DC50-380V

Cooling

Capacity

Btu/h

9000(3500-11000)

12000(3700-14000)

18000(6200-19500)

24000(5100-26900)

Input

W

590(100-1200)

865(110-1500)

1320(140-1800)

1980(240-3030)

Ratedcurrent

A

  1. (0.45-5.45)
  2. (0.5-6.82)

6(0.6-8.18)

9(1.0-13.2)

Heating

Capacity

Btu/h

9500(3800-11500)

13000(4000-15000)

19000(4700-20000)

25000(5500-30000)

Input

W

625(120-1200)

880(130-1510)

1465(200-1900)

2050(260-3140)

Ratedcurrent

A

  1. (0.5-5.45)

4(0.59-6.86)

  1. (0.9-8.63)
  2. (1.1-13.7)

Indoorairflow(Hi/Mi/Lo)

m3/h

559/454/366

559/454/366

721/566/458

970/780/590

Indoornoiselevel(Hi/Mi/Lo)

dB(A)

45/36/31.5

Indoorunit

Dimension(W*D*H)

mm

850x185x290

850x185x290

957x213x302

1040×220×327

Packing(W*D*H)

mm

950x290x385

950x290x385

1035x305x380

1120x310x405

Net/Grossweight

Kg

Outdoornoiselevel

dB(A)

<50

<50

<52

≤56

Outdoorunit

Dimension(W*D*H)

mm

835*320*540

835*320*540

835*320*540

910*340*700

Packing(W*D*H)

mm

900*400*600

900*400*600

900*400*600

1063*457*780

Net/Grossweight

Kg

33/39

35/40

39/44

56/62

Operationtemp

17℃~30℃

17℃~30℃

17℃~30℃

17℃~30℃

Ambienttemp(cooling/heating)

18-52/-15-34

18-52/-15-34

18-52/-15-34

18-52/-15-34

Applicationarea

m2

12-18

16-23

24-35

32-47

Qty’per20’/40’/40'HQ

87/174/211

87/174/211

83/166/202

52/104/128

Suntchigroup is a professional hybrid solar air conditioner manufacturers, we provide hybrid solar ac, solar ac dc hybrid air conditioner, acdc hybrid solar air conditioner, ac dc solar air conditioner, hybrid solar air conditioning system, solar hybrid inverter air conditioner, hybrid airconand etc. Want to know more? Contact us.



在线联系供应商

至: JIANGSU SUNCHI NEW ENERGY CO.,LTD.
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

DC Inverter Hot Water Heat Pump
DC Inverter Hot Water Heat Pump Inverter hot water heat pumpis an energy-saving device that uses high-grade energy to make the heat flow from the low-grade heat source to the hig...
9kw Air Source Heat Pump
9kw Air Source Heat Pump SUNCHI DC inverter house 9kw heat pumpsupplies the most energy saving hot water for house heating and domestic use in winter, and cooled water for ...
18 Kw Air Source Heat Pump
18 Kw Air Source Heat Pump 18 kW air source heat pumpwith Enhanced Vapor Injection (EVI)technology for dedicated heat pump applications, deliver outstanding performance and r...
20 Kw Air Source Heat Pump
20 Kw Air Source Heat Pump 20 kw air source heat pumpfeature : Save money: Heat pump is a high efficiency water heater, to supply 4kw energy; it just consumes 1kw electric p...
18 Kw Air Source Heat Pump
18 Kw Air Source Heat Pump is divided into indoor unit and outdoor unit. The outdoor unit is a condensing unit. It is the same thing as an air conditioner. It is only a fan....
供应产品

Same products

科摩罗液氮低温冷冻机 KGSQ ln2 容器
科摩罗液氮低温冷冻机 KGSQ ln2 容器 卖方: 河南天之道生物科技有限公司 在实验室,细胞样本需要放入液氮中进行低温保存,可是有些样本不仅要低温保存,还要气相储存,不与液氮接触。前者用常规液氮罐可解决问题,后者用气相液氮罐也能解决。不过,气相罐的容量都比较大,在350升...
文莱ln2低温冷冻机KGSQ液氮低温罐
文莱ln2低温冷冻机KGSQ液氮低温罐 卖方: 河南天驰仪器设备有限公司 在实验室,细胞样本需要放入液氮中进行低温保存,可是有些样本不仅要低温保存,还要气相储存,不与液氮接触。前者用常规液氮罐可解决问题,后者用气相液氮罐也能解决。不过,气相罐的容量都比较大,在350升...
不丹ln2低温冷冻机KGSQ液氮罐出售
不丹ln2低温冷冻机KGSQ液氮罐出售 卖方: Henan Tianzhidao Biological Technology Co., Ltd. 在实验室,细胞样本需要放入液氮中进行低温保存,可是有些样本不仅要低温保存,还要气相储存,不与液氮接触。前者用常规液氮罐可解决问题,后者用气相液氮罐也能解决。不过,气相罐的容量都比较大,在350升...
MONSA® DDAC-50
MONSA® DDAC-50 卖方: Guangzhou Monsa Chemical Co., Ltd INCI name: MONSA® DDAC-50 It functions by causing the cell membrane of bacteria to rupture...
MONSA® DCA-50
MONSA® DCA-50 卖方: Guangzhou Monsa Chemical Co., Ltd INCI name: disodium cocoampho diacetate Disodium cocoamphodiacetate for skinis a very mild amp...