.

Safety Relay

Safety Relay

Automation direct safety monitering relays are mainly applied to the safety control circuit, connecting the safety sensing elements and mechanical equipment motion controller. The working principle of safety relay interlock system: when there is a fault in the safety circuit, the intrinsic safe relayautomatically detects the fault and stops the machine movement, to protect equipment and personnel safety.

Chenzhu solid state safety rated relay is the first product to get PLe/Cat.4, SIL3 certified in China mainland. Automation and safety is the main character of the programmable safety relay module that you can be assured.

Various safety relay products are available for you to select. We have safety relay for E-stop buttons, emergency stop buttons, two-hand control buttons. We also provide light curtain safety relay, sil 2 rated relay and sil 3 rated relays to better meet the needs of our customers. For more information, please feel free to contact us.

Safety Relay Types

CZSR Classic Series Safety Relay

E-Stop Button, Safety Gate Safety Relay

Light Curtain Safety Relay

Two-hand Push Buttons Safety Relay

Safety Mat Safety Relay

Extension Module Safetu Relay

CZSR Process Series Safety Relay

DO Signal (SIS) 24V DC 2A Safety Relay

DO Signal (SIS) 24V DC 3A Safety Relay

DO Signal (SIS) Input 24V DC 5A Safety Relay

CZSR Smart Series Safety Relay

FAQ of Safety Relay

Q

What is safety relay?

A

Safety relay offer an extra level of protection usually through a redundant wiring system.

These relays are used to enable an monitor the signals between other safety devices such as safety switched sensors, light curtains, intrinsic safety barriers and isolators. In many cases, the safety relay can be paired with a safety PLC configurable safety relay or safety controller.

Q

What is the difference between safety relay and normal relay?

A

Compared to a normal relay, a safety control relay have mandatory steering contact arrangement assures protection when contact fusion happens. A safety relay is a module composed of multiple relays and logic circuits. It is a circuit composition unit. In order to achieve the correct and low malfunction feature and to minimize errors and failure values, and complete each other's faults in a fault state to enhance safety factors.

Q

How does an intrinsically safe barrier work?

A

Safety relays are generally composed of two or more relays and electronic circuits, so as to complement each other's abnormal defects. Even if any component fails, it can diagnose the failure and enter a safe state. And it will not affect the shutdown instructions issued to the machine, ensuring the safety of production. From the structural point of view, the safety relay generally adopts a dual-channel structure, and the channels can diagnose each other, and use a forced-oriented relay to realize the diagnosis of the output contact fusion fault.

Q

How do safety relays improve safety?

A

Like electrical panel box surge protector, safety relays are devices that implement safety functions. When a danger occurs, the safety relay will play a role in reducing the danger to an acceptable level. When an error occurs, the safety relay will initiate a safe and reliable response. Each safety relay monitors a specific function.

Q

What are the main applications of safety relays?

A

Suitable for the application of electromagnetic door lock switch to ensure the safety of the work area.

It is suitable for the key to cooperate with the safety gate switch to detect the opening and closing of the door.

Applicable to safety gates, detecting the position of the door, opening or closing applications.

Suitable for light beam devices to prevent workers from entering the dangerous work area.

Applicable safety mat switch to confirm that workers can safely enter the hazardous work area.

Applicable E-stop buttons, in case of emergency, stop the machine operation.

Q

What's the line monitoring function of Safety Relay?

A

Line monitoring is the basic function for safety relay which is used into SIS, which all CHENZHU automation direct safety relayofferred and built to PCB. Just input the DO signal and safety relay will check the test pulse automatically. When pulse error happens, safety relay will cut off the output so that to ensure SIF to work.

CHENZHU manufactures the most reliable interface product for safety automation system. We are here to help your device run more safely. Here you can not only get world-class products, but also outstanding service for safety and automation system.


在线联系供应商

至: Shanghai Chenzhu Instrument Co., Ltd.
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Intrinsic Isolated Barrier
Intrinsic Isolated Barrier Isolated barrier uses intrinsically safe explosion-proof and functional safety technologies and adopts various measures such as rapid cut-off, isol...
CZ2000 Series Signal Conditioner
CZ2000 Series Signal Conditioner CZ2000 analog signal isolator, analog voltage isolator CZ2000 range voltage signal conditioneruse high-efficiency electromagnetic isolation techno...
GS8500-EX Temperature Converter Intrinsic Safety Barrier
GS8500-EX Temperature Converter Intrinsic Safety Barrier Temperature input isolated barriers, converter potentiometer/RTD/TC signals in hazardous area into 0/4~20mA or 0/1~5V signals and output to safe ar...
Light Curtain Safety Relay
Light Curtain Safety Relay Light curtain Safety Relaysupports PNP-type light beam devices. Safety relay modules provide a high level of fail-safe operation for critical proce...
Low Power SPD
Low Power SPD The low voltage surge protection deviceis designed to prevent transient surge conditions. T range SPD for low power supply is used for protecting 2...
供应产品

Same products

Body-Worn Camera
Body-Worn Camera 卖方: Shenzhen Tianlong Century Technology Development CO., LTD Body-Worn Camera The Body-Worn Camerais a portable audio and video recording device that enhance...
Uphone L403 4G Rugged Scanner Smart Handheld Terminal 4800mAh
Uphone L403 4G Rugged Scanner Smart Handheld Terminal 4800mAh 卖方: Shenzhen Tianlong Century Technology Development CO., LTD Uphone L403 4G Rugged Scanner Smart Handheld Terminal 4800mAh The Uphone L403is a rugged 4G smar...
Uphone L611 Rugged Scanning Handheld Terminal 5000mAh IP67
Uphone L611 Rugged Scanning Handheld Terminal 5000mAh IP67 卖方: Shenzhen Tianlong Century Technology Development CO., LTD Uphone L611 Rugged Scanning Handheld Terminal 5000mAh IP67 The Uphone L611is a rugged 4G smart h...
PoC Radio
PoC Radio 卖方: Shenzhen Tianlong Century Technology Development CO., LTD PoC Radio PoC Radiois a solution for wide-area and multimedia cluster communication using cellul...
Air insulated Dry type transformer VPI
Air insulated Dry type transformer VPI 卖方: TAILI ELECTRIC CO.,LTD. Air insulated Dry type transformer VPI TAILI SG(B) air-barrier dry-type transformer( VPI) is des...