Pultruded Fiberglass Shapes

Cable trayis assembled by pultruded/FRP profiles;suitable for electrical cable, control cables, lightening cable and fittings. There are , fiberglass tank, fiberglass tube and vessel.

Advantage:

Application:

KQJ series cable tray is suitable for voltage below 10 kV electrical cables, control cable, and lightening fitting cables of below 10 kV and the lay out for indoor, outdoor, aerial, channel for cable and tunnel.

Structural features:

KQJ serial cable trays have the features that: widely used, high strength, reasonable structure, low cost, easy for construction, flexible fittings, nice-looking appearance, which make expansion, rebuilding, maintenance much easier.

Installation:

The installation of KQJ series cable tray can be per the local conditions can be laid according to the process requirements, such as plumbing, floor, hoisting under the beam, indoor and outdoor wall, tunnel, cable trench side wall mounted, but also on the open column.

When height of groove of cable tray is 50,100 mm, 6 connection holes for each end; when height of groove of cable tray is 150,200 mm, 12 connection holes for each end.

Support Spacing: it shall be less than or equal load curve, allowable load and support span.

Width: when we are electing the width of cable tray, we should leave enough spare space for new cables in the future.

Separated lying: when there are less power cables and control cables, they can be installed in the same cable tray, but there should be a separation plate between the power cable and control cable.

Fixing of cables: when the cable trays are horizontal laid, the connection point shall be in the position of 1 / 4, horizontal cable shall be fixed every 2 meters, the vertical cable trays shall be fixed every 1.5 meters.

Arrangement of cables in the cable tray

Weak current control cables shall be at the top layer, general control cables and low voltage power cable are downward arrangement. This kind of arrangement is good for shielding; good for cooling and site construction.

Spacing between cable trays

To ensure easy installation, cable tray and the spacing must satisfy the following data:

a ,when we are setting cable trays in the same support beam or in the same horizontal level, the net distance between adjacent cable trays should not be less than 50mm.

b, for two parallel cable tray, its net distance should not be less than 600mm.

When the cable trays are overlapped laid, the vertical distance shall meet the following data:

a, for power cable, it should be 300mm.

b, the control cable, it should be 250mm.

For the convenience of cable tray installation, the distance between cable tray and the top of the ceiling, beams and other obstacles at the bottom should meet the following data:

a, for power cable, it should be not less than 400mm.

b, for control cable, it should be not less than 250mm.

Notes

Vertical cable trays must be protected by cover on the area which is within two meters above the ground.

The position which is liable to mechanical damage must be protected by covers.

When the cable trays are horizontally laid, the selection of stride support shall be per the load curve; when the cable trays are vertically laid, there should be a fixing frame every 1 or 2 meters to make sure the stability of the cable trays.

When the cables in the cable tray are lead from horizontal direction to vertical direction, there must be a guide plate to protect the cable from damage.

When the material of cable tray is steel, there should be a reliable grounding wire; cable trays must be connected with the main grounding wire.


在线联系供应商

至: Hebei FUSHENG FRP CO.,LTD
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

SOP Production Line
SOP Production Line Our company can produce the whole set of . This technology is one of most advanced production methods of potassium sulfate. The core is updated new...
GRP/FRP Grating
GRP/FRP Grating is GRP/FRP plates with many uniform distributing rectangular and square blanks which are manufactured with molding confectioning technology. It has...
Dual Laminate Equipment
Dual Laminate Equipment In 1952, 'Dual Laminate technology' was introduced  to the chemical industry. Dual Laminate construction combines the superior chemical resistance ...
Carbon Electrodes
Carbon Electrodes Note: We sold carbon electrodesas an export agent for a manufacturer in our local place, Because we are in a small city and many companies have no ...
Large GRP Tank Production Line
Large GRP Tank Production Line FW-10000VI Computer Control Site The major properties of the equipment are below. FW-15000VI Computer Control Site Winding Machine The major prope...
供应产品

Same products

LANRUI AA-12 4.2V 电源启动线,适用于 iPhone 和安卓手机
LANRUI AA-12 4.2V 电源启动线,适用于 iPhone 和安卓手机 卖方: Phonefix LANRUI AA-12 4.2V 电源启动线是一款专业的手机硬件诊断工具。这款多功能启动线支持 iPhone 8 系列至 17 Pro Max 机型,以及包括华为、三星、vivo、小米和 OP...
MTFH63-211GRB-11A36 11Pin PH1.27mm Vertical Dual Row Female Header
MTFH63-211GRB-11A36 11Pin PH1.27mm Vertical Dual Row Female Header 卖方: MTCONN ELECTRONICS CO.,LTD This dual-row vertical surface-mount (SMT) gold-plated headerfeatures a 1.27mm pitch design with ...
HM Pumex Grinding Machine
HM Pumex Grinding Machine 卖方: Shenzhen JuYongNeng Technology Co., Ltd HM Pumex Grinding Machine Product Description Name TSP HM3/6-75 S/Z...
UV Detector
UV Detector 卖方: 淮安市鑫盛制药设备有限公司 A DAC column,or Dynamic Axial Compression column,is a self-packingcolumn used for separation in l...
China manufacturer Turbine bolt electric heater ZJ-17-T4 for power generation
China manufacturer Turbine bolt electric heater ZJ-17-T4 for power generation 卖方: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD "China manufacturer Turbine bolt electric heater ZJ-17-T4 for power generation Is YOYIK for the u...