(N)TSCGEWOEU Medium-Voltage Fixed Installation Cable With Fiber Optics

(N)TSCGEWOEU Medium-Voltage Fixed Installation Cable With Fiber OpticsApplicationsThese cables are used for For laying alongside the conveyor belts (also for shiftable units)and on material handling equipment (even with continuous movementsuch as in cable booms or as connection between upperand lower car) and for connection of submersible pump units.StandardsBased on VDE 0250 Part 813ConstructionConductorsFlexible strandedcopper conductor,Website:, class 5 according to DIN VDE 0295.Inner Conductor LayerSemiconductive layer.InsulationEPR.Outer Conductor LayerSemiconductive layer.Earth ConductorSplit into two in the outer interstices.Fiber OpticsFO 50/125 or 62.5/125 orE9/125μm within protection sheath.InnerSheathEPR.Outer SheathCM.Dimensions and Weight3.6/6 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×(6LWL)40.143.126503×25+2×50/2+1×(6LWL)42.445.430603×35+2×25/2+1×(6LWL)42.345.330603×35+2×50/2+1×(6LWL)44.047.034103×50+2×25/2+1×(6LWL)43.846.834903×50+2×50/2+1×(6LWL)46.149.136403×70+2×35/2+1×(6LWL)47.050.043503×70+2×50/2+1×(6LWL)52.056.052803×95+2×50/2+1×(6LWL)52.256.255503×120+2×70/2+1×(6LWL)49.650.970403×150+2×70/2+1×(6LWL)48.452.380003×185+2×95/2+1×(6LWL)51.355.393103×240+2×120/2+1×(6LWL)58.062.0119403×300+2×150/2+1×(6LWL)63.267.2142306/10 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×(6LWL)41.444.427703×25+2×50/2+1×(6LWL)43.146.131203×35+2×25/2+1×(6LWL)43.646.631903×35+2×50/2+1×(6LWL)44.747.734703×50+2×25/2+1×(6LWL)45.148.136203×50+2×50/2+1×(6LWL)46.849.840103×70+2×35/2+1×(6LWL)48.351.345003×70+2×50/2+1×(6LWL)52.756.753603×95+2×50/2+1×(6LWL)53.557.557103×120+2×70/2+1×(6LWL)57.261.268303×150+2×70/2+1×(6LWL)62.366.381803×185+2×95/2+1×(6LWL)65.369.395003×240+2×120/2+1×(6LWL)73.477.4121603×300+2×150/2+1×(6LWL)78.682.6144608.7/15 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×(6LWL)44.247.230503×25+2×50/2+1×(6LWL)45.448.433503×35+2×25/2+1×(6LWL)45.348.333203×35+2×50/2+1×(6LWL)47.050.037103×50+2×25/2+1×(6LWL)49.453.441603×50+2×50/2+1×(6LWL)51.255.245903×70+2×35/2+1×(6LWL)52.756.750803×70+2×50/2+1×(6LWL)55.059.056403×95+2×50/2+1×(6LWL)57.061.061603×120+2×70/2+1×(6LWL)62.166.175203×150+2×70/2+1×(6LWL)65.769.786703×185+2×95/2+1×(6LWL)68.772.7100103×240+2×120/2+1×(6LWL)76.880.8127303×300+2×150/2+1×(6LWL)82.086.01508012/20 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×(6LWL)45.548.531403×25+2×50/2+1×(6LWL)47.250.235303×35+2×25/2+1×(6LWL)48.351.336403×35+2×50/2+1×(6LWL)51.055.042403×50+2×25/2+1×(6LWL)52.556.545303×50+2×50/2+1×(6LWL)52.556.546903×70+2×35/2+1×(6LWL)55.759.754603×70+2×50/2+1×(6LWL)58.062.060403×95+2×50/2+1×(6LWL)61.465.467703×120+2×70/2+1×(6LWL)65.169.179503×150+2×70/2+1×(6LWL)68.772.791303×185+2×95/2+1×(6LWL)73.277.2107703×240+2×120/2+1×(6LWL)79.883.8132603×300+2×150/2+1×(6LWL)86.391.31604014/25 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×(6LWL)50.354.337403×25+2×50/2+1×(6LWL)50.354.339003×35+2×25/2+1×(6LWL)53.157.142703×35+2×50/2+1×(6LWL)53.157.144403×50+2×25/2+1×(6LWL)56.360.350003×50+2×50/2+1×(6LWL)56.360.351603×70+2×35/2+1×(6LWL)61.065.061903×70+2×50/2+1×(6LWL)61.065.063903×95+2×50/2+1×(6LWL)65.369.373403×120+2×70/2+1×(6LWL)69.073.085503×150+2×70/2+1×(6LWL)74.078.0100203×185+2×95/2+1×(6LWL)77.081.0114103×240+2×120/2+1×(6LWL)85.090.0143803×300+2×150/2+1×(6LWL)90.295.21682018/30 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×(6LWL)53.757.741403×25+2×50/2+1×(6LWL)53.757.743103×35+2×25/2+1×(6LWL)56.660.647203×35+2×50/2+1×(6LWL)56.660.648803×50+2×25/2+1×(6LWL)61.265.256803×50+2×50/2+1×(6LWL)61.265.258403×70+2×35/2+1×(6LWL)64.468.466703×70+2×50/2+1×(6LWL)64.468.468703×95+2×50/2+1×(6LWL)68.772.778603×120+2×70/2+1×(6LWL)73.877.893503×150+2×70/2+1×(6LWL)77.581.5106303×185+2×95/2+1×(6LWL)80.584.5120403×240+2×120/2+1×(6LWL)88.593.5150703×300+2×150/2+1×(6LWL)94.799.717780
Other supplier products
|
|
FL2XCY Airport Cable |
FL2XCY Airport Cable
Applications
These cables are used as airfield lighting equipment primary cables for the series circuit connecting the Constan... |
|
|
FAA L-824 Type C 600V Airport Cable |
FAA L-824 Type C 600VAirport Cable
Applications
These cables are designed for use in airport lighting and control circuits, suitable for installat... |
|
|
Aerial Bundled Cables to NFC 33-209 (AL/XLPE) |
Aerial Bundled Cables to NFC 33-209 (AL/XLPE)
Application
The aerial bundled cables designed for fixed installation as overhead power lines up to 1... |
|
|
FLYCY Airport Cable |
FLYCY Airport Cable
Applications
These cables are used as airfield lighting equipment primary cables for the series circuit connecting the Constant... |
|
|
FAA L-824 Type B Unshielded 5kV Airport Cable |
FAA L-824 Type B Unshielded 5kV Airport Cable
Applications
These cables are used for interconnecting the transformers and the current regulator of... |