ct pt analyzer HYVA-405
|
Tests for Current Transformer: 1 Excitation curve and parameters test Tests for Voltage Transformer: 1 Turns ratio test |
| CT PT Tester application 1 CT nameplate check 2 CT parameters check in work burden 3 CT transient parameters analysis 4 CT ratio and phase error calibration 5 PT routine test |
| 1 Test standards: IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13 2 Power supply: AC220V±10%, 50/60Hz±10% 3 Voltage output: 0.1~180V (AC) 4 Current output: 0.001~5A(RMS) 5 Power output: 500VA 6 Maximum knee voltage measurement: 45KV 7 Current measurement: Range: 0~10A (automatically change range in 0.1/0.4/2/10A) Error: <±0.1%+0.01%FS 8 Voltage measurement: Range: 0~200V (automatically change range in 1V/10V/70V/200V) Error: < ±0.1%+0.01%FS 9 Turns ratio measurement: Range:1~35000 1~2000 error<0.05% 2000~5000 error<0.1% 5000~35000 error<0.2% 10 Phase measurement: error: ±2min; resolution: 0.01min 11 Winding resistance measurement: Range: 0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm) Error: < 0.2%RDG+0.02%FS Maximum resolution: 0.1mΩ 12 Temperature measurement:-50~100 Celsius degree; error<3 Celsius degree 13 CT Secondary burden: Range: 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm) Error: <0.2%RDG+0.02%FS Maximum resolution: 0.001ohm 14 PT Secondary burden: Range: 0~80kohm (automatically change range in 800ohm/8kohm/80kohm) Error :<0.2%RDG+0.02%FS Maximum resolution: 0.1ohm 15 PT ratio measurement: Range: 1~35000 1~10000 error<0.1% 10000~35000 error<0.2% 16 PT ratio error measurement: Typical error <0.05%, Maximum Error<0.1% 17 PT phase angle measurement: maximum error < 3min 18 Make evaluation for test results according to selected standards 19 Make word report for test result 20 Make word reports one time for multi-group test records on the PC 21 Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test 22 Compare excitation curves with saved excitation curves in the same window 23 Memory capacity: >1000 groups test results 24 Working condition: temperature: -10℃~50℃; moist: ≤90% 25 Size: 485mm×356mm×183mm 26 Weight: <15kg |
在线联系供应商
Other supplier products
| HY2303 Insulation Tester | Rated Voltage 2500V 5000V 10000V Measuring Range 0.0~99.9MΩ100~999MΩ1.00~9.99GΩ10.0~100GΩ 0.0~99.9MΩ100~999M&O... | |
| YJJ-ⅡInsulating Oil Tester | Dielectric oil tester functions: 1 Breakdown test of user-defined2 Proof test3 Calibration interface for customers4 Result print Insulating oil tes... | |
| HY2305 Insulation Tester | Insulation Tester HY2305 RatedVoltage 250V 500V 1000V 2500V 5000V Measuring Range 0.0~99.9MΩ100~999MΩ1.00~10.0GΩ 0.0~99.9... | |
| HYKC-2000 On Load Tap Changer Ohmmeter Analyzer | 1.Introduction On load tap changer analyzer HYKC-2000 is mainly applied to test transient time, transition waveform, transition resistance, sync... | |
| HYHL series contact resistance tester | Contactresistance tester application: HYHL Series contact resistance testeris applied in circuit breaker testing and power cable connection qualit... |
Same products
| JXF Distribution Box | 卖方: Jiangsu Aokai Electric Co., Ltd | JXF Distribution Boxis a modular distribution box with advanced technology and performance introd... | |
| XL Power Distribution Switchgear | 卖方: Jiangsu Aokai Electric Co., Ltd | XL-21 power distribution boxis suitable for ac 50 (60) HZ, voltage to 690V, power supply system, ... | |
| Common Rail Injector Nozzle 880P119092 | 卖方: China lutong | Common Rail Injector Nozzle 880P119092 Common Rail Injector Nozzle A6510702887Chris Whats/ app:+... | |
| Bently Nevada AC Power Supply PN 127610-01 of 3500/15 | 卖方: 840499 | 3500/15 127610-01 | Bently Nevada | 3500/15 交流电源模块(停产。新替代品:106M1079-01:通用交流电源模块)3500/15 127610-01... | |
| 隧道专用箱变 | 卖方: 839459 | 隧道专用箱变是针对在隧道环境中使用而专门设计的产品,针对隧道内湿度大,运行空间狭小等特殊性,该产品采用全密封双层隔温分体式箱体,配备凝露控制器与温度控制器,实现实时监控与自启动的功能,有效保证隧... |