S11 Series 6kV-35kV power Transformer With Off Circuit Tap Changer,power oill transformer,high voltage step up transformer,distribution transformer
S11 Series 6kV-35kV power Transformer With Off Circuit Tap Changer,power oill transformer,high voltage step up transformer,distribution transformer
The products implement the National Standard GB1094-2013 Power Transformer and GB / T6451-2015 Three-phase Oil-immersed Power Transformer Technical Parameters and Requirements, and are recommended as the major equipment products for the national urban and rural power grid construction and retrofit by the State Economic and Trade Commission.
Product Description
The products implement the National Standard GB1094-2013 Power Transformerand GB / T6451-2015 Three-phase Oil-immersed Power Transformer Technical Parameters and Requirements, and are recommended asthe major equipment products for the national urban and rural power grid construction and retrofit by the State Economic and Trade Commission.
S11 series transformer adopts high quality material for copper winding, especially applying the new technology and new material for the coil insulation and active parts, thus the no-load and the load loss are obviously reduced, the performance and structure are more reliable and superior.
Product Features
- Good Economic Performance
The no-load loss for S11 series products decreased 10.3% averagely, no-load current decreased 22.4%based on S9 series.
- Long Service Life
Transformer tank adopts hermetical structure, tank and tank cover can be connected by bolts or welded firmly, the transformer oil won’t contact with air,so that extend the service life effectively.
- High Operation Reliability
Improve the relevant sealing parts for the tank, increase the reliability and advance the technical level to ensure the reliability of the seal.
- Small Installation Area
S11-M series transformer tank uses the corrugated plate radiator. When the oil temperature changes, the corrugated plate will proceed thermal expansion, which can replace the role of the oil conservator. the corrugated plate tank has beautiful appearance, less occupied area.
Model and Meaning
Table 1: 6Kv, 10kV & 30kVA-2500kVA Power Transformer With Off Circuit Tap Changer
Rated Capacity (kVA) |
Voltage Combination |
Connection Group Symbol |
No-load Loss R(W) |
Load Loss R(W)75℃ |
Impedance Voltage (%) |
No-load Current(%) |
Length L(mm) |
Width W (mm) |
Height H(mm) |
Gauge Horizontal*Vertical(mm) |
Active parts Weight(Kg) |
Oil Weight(Kg) |
Total Weight(Kg) |
||
(KV) High Voltage |
Tapping Range of High Voltage |
(KV)Low Voltage |
|||||||||||||
30 |
±5%±2×2.5% |
Dyn11Yzn11Yyn0 |
100 |
630/600 |
980 |
735 |
1145 |
400*400 |
178 |
78 |
355 |
||||
50 |
130 |
910/870 |
1017 |
758 |
1205 |
450*400 |
240 |
92 |
415 |
||||||
63 |
150 |
1090/1040 |
1035 |
785 |
1285 |
450*400 |
285 |
105 |
505 |
||||||
80 |
180 |
1310/1250 |
1065 |
800 |
1290 |
450*400 |
330 |
110 |
540 |
||||||
100 |
200 |
1580/1500 |
1072 |
820 |
1305 |
450*400 |
345 |
116 |
590 |
||||||
125 |
240 |
1890/1800 |
1155 |
1105 |
1310 |
450*550 |
415 |
135 |
705 |
||||||
160 |
280 |
2310/2200 |
1235 |
850 |
1535 |
550*550 |
485 |
155 |
835 |
||||||
200 |
340 |
2730/2600 |
1282 |
860 |
1557 |
550*550 |
582 |
168 |
965 |
||||||
250 |
400 |
3200/3050 |
1310 |
940 |
1605 |
550*550 |
695 |
210 |
1135 |
||||||
315 |
480 |
3830/3650 |
1465 |
1120 |
1915 |
660*650 |
855 |
255 |
1520 |
||||||
400 |
570 |
4520/4300 |
1440 |
1165 |
1725 |
660*660 |
950 |
295 |
1590 |
||||||
500 |
680 |
5410/5150 |
1510 |
1250 |
1845 |
660*650 |
1150 |
320 |
1905 |
||||||
630 |
810 |
6200 |
1650 |
1140 |
1920 |
660*650 |
1500 |
435 |
2015 |
||||||
800 |
980 |
7500 |
2125 |
1175 |
2315 |
820*820 |
1910 |
760 |
3510 |
||||||
1000 |
1150 |
10300 |
2150 |
1380 |
2570 |
820*820 |
2125 |
880 |
3850 |
||||||
1250 |
1360 |
12000 |
2355 |
1485 |
2570 |
820*820 |
2605 |
960 |
4610 |
||||||
1600 |
1640 |
14500 |
2385 |
1750 |
2630 |
820*820 |
3125 |
1150 |
5420 |
||||||
2000 |
1940 |
18300 |
1940 |
1400 |
1700 |
820*820 |
2420 |
780 |
4200 |
||||||
2500 |
2290 |
21200 |
2050 |
1480 |
1800 |
820*820 |
2560 |
880 |
4680 |
Notes:
Technical Parameter for S11 Series 20kV Power Transformer With Off Circuit Tap Changer
Rated capacity(KVA) |
Voltage Combination |
Connection Group Symbol |
No-load Loss(W) |
Load Loss (W)75℃ |
No-load Current (%) |
Short-circuit Impedance(%) |
||
High Voltage (KV) |
Tapping ranges of High Voltage |
Low Voltage(KV) |
||||||
30 |
20 |
±5% ±2×2.5% |
Dyn11Yzn11Yyn0 |
100 |
690/660 |
|||
50 |
130 |
1010/960 |
||||||
63 |
150 |
1200/1150 |
||||||
80 |
180 |
1440/1370 |
||||||
100 |
200 |
1730/1650 |
||||||
125 |
240 |
2080/1980 |
||||||
160 |
290 |
2540/2420 |
||||||
200 |
340 |
3000/2860 |
||||||
250 |
400 |
3520/3350 |
||||||
315 |
480 |
4210/4010 |
||||||
400 |
570 |
4970/4730 |
||||||
500 |
680 |
5940/5660 |
||||||
630 |
810 |
6820 |
||||||
800 |
980 |
8250 |
||||||
1000 |
1150 |
11330 |
||||||
1250 |
1380 |
13200 |
||||||
1600 |
1660 |
15950 |
||||||
2000 |
1950 |
19140 |
||||||
2500 |
2340 |
22220 |
Notes:
Technical Parameter for S11 Series 35kV Power Transformer With Off Circuit Tap Changer
Model |
Voltage Combination |
Connection Group Symbol |
No-load Loss (W)75℃ |
Load Loss R(W) |
Impedance Voltage (%) |
No-load Current(%) |
Length L(mm) |
Width W(mm) |
Height H(mm) |
Gauge Horizontal*Vertical (mm) |
Active parts Weight(Kg) |
Oil Weight(Kg) |
Total Weight(Kg) |
||
High Voltage (kV) |
Tapping Range of High Voltage % |
Low Voltage (kV) |
|||||||||||||
50 |
±2×2.5%±5% |
Dyn11/ Yyn0 |
160 |
1200/1140 |
1195 |
935 |
1825 |
660*660 |
300 |
330 |
860 |
||||
100 |
230 |
2010/1910 |
1200 |
995 |
1935 |
660*660 |
470 |
383 |
1130 |
||||||
125 |
270 |
2370/2260 |
1235 |
940 |
1955 |
660*660 |
550 |
465 |
1335 |
||||||
160 |
280 |
2820/2680 |
1285 |
895 |
1950 |
660*660 |
580 |
485 |
1475 |
||||||
200 |
340 |
3320/3160 |
1310 |
1150 |
1985 |
660*660 |
680 |
595 |
1755 |
||||||
250 |
400 |
3950/3760 |
1450 |
1090 |
2010 |
660*660 |
860 |
650 |
2000 |
||||||
315 |
480 |
4750/4530 |
1930 |
1065 |
2320 |
820*820 |
980 |
765 |
2290 |
||||||
400 |
580 |
5740/5470 |
1850 |
1165 |
2015 |
820*820 |
1170 |
885 |
2725 |
||||||
500 |
680 |
6910/6580 |
2045 |
1205 |
2415 |
820*820 |
1340 |
960 |
3090 |
||||||
630 |
830 |
7860 |
2085 |
1240 |
2515 |
660*660 |
1550 |
895 |
3810 |
||||||
800 |
980 |
9400 |
2305 |
1615 |
2685 |
820*820 |
1990 |
1030 |
4510 |
||||||
1000 |
1150 |
11500 |
2545 |
1540 |
2590 |
1070*1070 |
2415 |
1475 |
5055 |
||||||
1250 |
1400 |
13900 |
2495 |
2010 |
2675 |
820*820 |
2480 |
1405 |
5290 |
||||||
1600 |
1690 |
16600 |
2680 |
2100 |
2770 |
820*820 |
2600 |
1490 |
5450 |
||||||
2000 |
1990 |
19700 |
2790 |
2180 |
2860 |
820*820 |
2720 |
1590 |
5600 |
||||||
2500 |
2360 |
23200 |
2900 |
2290 |
2980 |
1070*1070 |
2830 |
1720 |
5760 |
Notes:
S11 Series 35kV 630kVA-31500kVA Three-phase Dual Winding Power Transformer With Off Circuit Tap Changer
Model |
Voltage Combination |
Connection Group Symbol |
No-load Loss (W) |
Load Loss R(W) |
No-load Current(%) |
Short circuit impedance (%) |
Length L(mm) |
Width W(mm) |
Height H(mm) |
Gauge Horizontal*Vertical (mm) |
Active parts Weight(Kg) |
Oil Weight(Kg) |
Total Weight(Kg) |
||
High Voltage (kV) |
Tapping Range of High Voltage % |
Low Voltage (kV) |
|||||||||||||
630 |
35 |
±2×2.5%±5% |
Yd11 |
830 |
7860 |
2400 |
1700 |
2210 |
820*820 |
2210 |
900 |
3250 |
|||
800 |
980 |
9400 |
2500 |
1850 |
2390 |
820*820 |
2350 |
1030 |
3500 |
||||||
1000 |
1150 |
1150 |
2700 |
1950 |
2510 |
820*820 |
2490 |
1180 |
3860 |
||||||
1250 |
1400 |
1390 |
2900 |
2050 |
2630 |
820*820 |
2600 |
1350 |
4350 |
||||||
1600 |
1690 |
1660 |
3050 |
2130 |
2750 |
820*820 |
2810 |
1580 |
4855 |
||||||
2000 |
2170 |
1830 |
3105 |
2195 |
2805 |
1070*1070 |
2800 |
1800 |
5300 |
||||||
2500 |
2560 |
1960 |
3150 |
2535 |
2980 |
1070*1070 |
3525 |
2060 |
7665 |
||||||
3150 |
35-38.5 |
±2×2.5%±5% |
3040 |
2300 |
3920 |
2725 |
2840 |
1070*1070 |
3995 |
2205 |
8565 |
||||
4000 |
3610 |
2730 |
3310 |
2915 |
3070 |
1070*1070 |
4825 |
2560 |
10115 |
||||||
5000 |
4320 |
3130 |
3480 |
3020 |
3145 |
1070*1070 |
5700 |
2635 |
11305 |
||||||
6300 |
5240 |
3500 |
3590 |
2905 |
3210 |
1475*1475 |
7120 |
3240 |
13510 |
||||||
8000 |
35-38.5 |
±2×2.5% |
YNd11 |
7200 |
3840 |
4070 |
3050 |
3595 |
1475*1475 |
8875 |
3840 |
16690 |
|||
10000 |
8700 |
4530 |
4106 |
2795 |
3655 |
2000*1475 |
10305 |
3600 |
17690 |
||||||
12500 |
1000 |
5380 |
4570 |
3010 |
3840 |
1475*1475 |
12830 |
4310 |
20990 |
||||||
16000 |
1210 |
6580 |
5235 |
3295 |
4615 |
2000*1475 |
16010 |
6650 |
27660 |
||||||
20000 |
1440 |
7950 |
5360 |
3415 |
4660 |
2000*1475 |
18820 |
7600 |
32170 |
||||||
25000 |
1700 |
9400 |
5830 |
3810 |
4860 |
2000*1475 |
22360 |
9800 |
42600 |
||||||
31500 |
2020 |
112000 |
6290 |
4290 |
5260 |
2000*1475 |
25110 |
12010 |
49960 |
Note: 1.For the transformer of low voltage 10.5kV, the connection group symbol is applicable to Dyn11.
Note: 2.For the transformer of rated capacity 3150kVA or above, the -5% tapping position is for maximum current tap.
Note: 3.When the annual average load rate for the transformer is between 35% to 45%, the loss value in the table can obtain the highest operational efficiency.
We are pleased to deliver Transformer, Distribution Transformer, Power Transformer, Oil Transformer, Dry Type Transformer. Safe payment and on time deliver time will give you.If you want to know more about the product, please click here.
在线联系供应商
Other supplier products
Transformer Fault Reasons And Preventive Measures | Oill Transformer Manufacturertells us that operators should be familiar with the causes of transformer faults so that they can take timely treatm... | |
What Are the Common Drying Methods for Transformers? | The following are common drying methods for transformers such asH Class Dry Type Transformerfor your reference: (1) If the transformer drying ch... | |
step up dry transformer | step up dry transformer Dry Type Transformer Flame retardant, non-pollution, it can be installed directly in the load center. Maintenance-free, eas... | |
Transformer Energy Saving is More and More Popularized | Transformers such asThree Phase Transformeralso have great developments and changes in the development experience, and the process of transformer ... | |
What is the short circuit impedance of transformer | What is the short circuit impedance of transformer Do you know what the short circuit impedance of transformer is? Transformer such as the, it is a... |
Same products
S11-M Power Transformer | 卖方: Bokong Electric Co., Ltd | S11-M Product Description S11-M a new generation of low noise and low loss transformer devel... | |
Compact Transformer | 卖方: Shaanxi Hanzhong Transformer Co., ltd | As a leading compact transformer substationmanufacturer and box type substation supplier, SEC com... | |
Combined Pad Mounted Substation | 卖方: Shaanxi Hanzhong Transformer Co., ltd | Combined Pad Mounted Substation The ZBG series America Housing Type Transformer are researched a... | |
Amorphous Alloy Dry Type Transformer | 卖方: Shaanxi Hanzhong Transformer Co., ltd | SCBH15eres amorphous alloy dry type transformerpertorms well not only for its excellent propertie... | |
35KV Power Transformer | 卖方: Shaanxi Hanzhong Transformer Co., ltd | This 35 KV transformerhas the characteristics of high efficiency and low loss, can save a lot of ... |