NTSCGEWOEU Flexible Medium-Voltage Trailing Cable VDE 0250 Part 813

NTSCGEWOEU Flexible Medium-Voltage Trailing Cable VDE 0250 Part 813ApplicationsThese cables are used as power supply or connection cables for large material handling machines,Website:, e.g. excavators in open-cast mines subject to extremely high mechanical stresses. Particularly suitable for applications in which abrasion and chaffing stresses are to be expected in trailing operation.StandardsVDE 0250 Part 813ConstructionConductorsFlexible strandedcopper conductor, class 5 according to DIN VDE 0295.Inner Conductor LayerSemiconductive layer.InsulationRubber type 3GI3.Outer Conductor LayerSemiconductive layer.Earth ConductorSplit into three in theouter interstices or Individual concentric distributed over core insulating coverings (coding…../3E).Reinforcing TapeExtremely tear-resistant reinforcing tape.InnerSheathRubber type 5GM5, abrasion and tear resistant, oil and ozone resistant.Outer SheathRubber type 5GM5, abrasion and tear resistant, oil and ozone resistant, inseparably bonded with inner sheath.Dimensions and Weight1.8/3kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/338.541.524703×35+3×25/342.945.930803×50+3×25/346.149.137503×70+3×35/349.753.746903×95+3×50/357.461.462103×120+3×70/361.265.274303×150+3×70/366.770.789003×185+3×95/370.674.6103303×25+2×25/2+1×10ST40.344.324703×35+2×25/2+1×10ST42.946.930803×50+2×25/2+1×10ST46.850.837503×70+2×35/2+1×10ST51.555.546903×95+2×50/2+1×10ST57.462.462103×120+2×70/2+1×10ST63.668.674303×150+2×70/2+1×10ST67.272.289003×185+2×95/2+1×10ST70.275.2103303.6/6kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/344.647.630803×35+3×25/347.650.635903×50+3×25/352.456.445203×70+3×35/356.360.355203×95+3×50/359.963.965803×120+3×70/365.669.681103×150+3×70/369.373.393203×185+3×95/373.277.2107803×25+2×25/2+1×10ST454932003×35+2×25/2+1×10ST47.651.636803×50+2×25/2+1×10ST535746403×70+2×35/2+1×10ST56.260.255503×95+2×50/2+1×10ST61.866.866503×120+2×70/2+1×10ST66.171.181603×150+2×70/2+1×10ST69.874.893403×185+2×95/2+1×10ST74.679.6108906/10 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/346.449.432703×35+3×25/349.153.138003×50+3×25/354.158.147503×70+3×35/3586257503×95+3×50/361.765.768303×120+3×70/367.471.483803×150+3×70/3717596203×185+3×95/376.780.7114303×25+2×25/2+1×10ST46.850.834103×35+2×25/2+1×10ST50.954.938903×50+2×25/2+1×10ST54.558.948603×70+2×35/2+1×10ST586257803×95+2×50/2+1×10ST63.568.569203×120+2×70/2+1×10ST67.872.884503×150+2×70/2+1×10ST71.576.596203×185+2×95/2+1×10ST76.381.3109808.7/15 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/352.656.640403×35+3×25/355.659.646303×50+3×25/358.962.953703×70+3×35/364.568.567203×95+3×50/368.272.278503×120+3×70/372.176.191303×150+3×70/377.681.6107503×185+3×95/381.585.5122903×25+2×25/2+1×10ST535741303×35+2×25/2+1×10ST55.659.647403×50+2×25/2+1×10ST59.363.354703×70+2×35/2+1×10ST64.668.668203×95+2×50/2+1×10ST68.373.379503×120+2×70/2+1×10ST74.479.492403×150+2×70/2+1×10ST78.183.1108603×185+2×95/2+1×10ST81.186.11240012/20 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/356.960.946203×35+3×25/359.963.952203×50+3×25/3656963003×70+3×35/368.972.974103×95+3×50/372.576.585603×120+3×70/378.282.2102603×150+3×70/381.985.9115703×185+3×95/387.492.4135303×25+2×25/2+1×10ST57.361.347703×35+2×25/2+1×10ST59.963.953403×50+2×25/2+1×10ST65.469.464603×70+2×35/2+1×10ST68.872.874503×95+2×50/2+1×10ST74.479.486803×120+2×70/2+1×10ST78.783.7103703×150+2×70/2+1×10ST82.287.2116503×185+2×95/2+1×10ST/25kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×10ST64.768.759403×35+2×25/2+1×10ST67.371.364703×50+2×25/2+1×10ST717573003×70+2×35/2+1×10ST75.280.288003×95+2×50/2+1×10ST8085100503×120+2×70/2+1×10ST85.990.9114703×150+2×70/2+1×10ST89.694.6132103×185+2×95/2+1×10ST92.697.61486018/30kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/369.573.566803×35+3×25/372.576.573803×50+3×25/377.681.684603×70+3×35/381.585.596903×95+3×50/384.989.9109603×120+3×70/390.695.6128303×150+3×70/394.399.3142503×185+3×95/×25+2×25/2+1×10ST69.973.971003×35+2×25/2+1×10ST72.676.675403×50+2×25/2+1×10ST788286803×70+2×35/2+1×10ST80.485.497603×95+2×50/2+1×10ST86.891.8111003×120+2×70/2+1×10ST91.196.1129803×150+2×70/2+1×10ST94.899.8143503×185+2×95/2+1×10ST99.6104.615870
Other supplier products
|
|
|
Belden8355
Website: |
|
|
|
German Standard Industrial Cables H05VV5-F(NYSLYÖ-JZ)Application and DescriptionThese cables are suitable for dry,Website:, damp and wet locations ... |
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 9843ApplicationsThese cables have pairs laid up in a foil/braid screen,Website:, s... |
|
|
|
S10 IYOI(c) 60 V NEK606 Armoured Tele cableApplications :These cables are flame retardant,Website:, low smoke and halogen free, used for indoor tel... |
|
|
|
N3GHSSYCY Medium-Voltage Cable VDE 0250 Part 605ApplicationsThese cables are used for the connection of mobile operatingequipment,Website:, in mine... |
供应产品
Same products