NTSCGEWOEU Flexible Medium-Voltage Trailing Cable VDE 0250 Part 813

NTSCGEWOEU Flexible Medium-Voltage Trailing Cable VDE 0250 Part 813ApplicationsThese cables are used as power supply or connection cables for large material handling machines,Website:, e.g. excavators in open-cast mines subject to extremely high mechanical stresses. Particularly suitable for applications in which abrasion and chaffing stresses are to be expected in trailing operation.StandardsVDE 0250 Part 813ConstructionConductorsFlexible strandedcopper conductor, class 5 according to DIN VDE 0295.Inner Conductor LayerSemiconductive layer.InsulationRubber type 3GI3.Outer Conductor LayerSemiconductive layer.Earth ConductorSplit into three in theouter interstices or Individual concentric distributed over core insulating coverings (coding…../3E).Reinforcing TapeExtremely tear-resistant reinforcing tape.InnerSheathRubber type 5GM5, abrasion and tear resistant, oil and ozone resistant.Outer SheathRubber type 5GM5, abrasion and tear resistant, oil and ozone resistant, inseparably bonded with inner sheath.Dimensions and Weight1.8/3kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/338.541.524703×35+3×25/342.945.930803×50+3×25/346.149.137503×70+3×35/349.753.746903×95+3×50/357.461.462103×120+3×70/361.265.274303×150+3×70/366.770.789003×185+3×95/370.674.6103303×25+2×25/2+1×10ST40.344.324703×35+2×25/2+1×10ST42.946.930803×50+2×25/2+1×10ST46.850.837503×70+2×35/2+1×10ST51.555.546903×95+2×50/2+1×10ST57.462.462103×120+2×70/2+1×10ST63.668.674303×150+2×70/2+1×10ST67.272.289003×185+2×95/2+1×10ST70.275.2103303.6/6kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/344.647.630803×35+3×25/347.650.635903×50+3×25/352.456.445203×70+3×35/356.360.355203×95+3×50/359.963.965803×120+3×70/365.669.681103×150+3×70/369.373.393203×185+3×95/373.277.2107803×25+2×25/2+1×10ST454932003×35+2×25/2+1×10ST47.651.636803×50+2×25/2+1×10ST535746403×70+2×35/2+1×10ST56.260.255503×95+2×50/2+1×10ST61.866.866503×120+2×70/2+1×10ST66.171.181603×150+2×70/2+1×10ST69.874.893403×185+2×95/2+1×10ST74.679.6108906/10 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/346.449.432703×35+3×25/349.153.138003×50+3×25/354.158.147503×70+3×35/3586257503×95+3×50/361.765.768303×120+3×70/367.471.483803×150+3×70/3717596203×185+3×95/376.780.7114303×25+2×25/2+1×10ST46.850.834103×35+2×25/2+1×10ST50.954.938903×50+2×25/2+1×10ST54.558.948603×70+2×35/2+1×10ST586257803×95+2×50/2+1×10ST63.568.569203×120+2×70/2+1×10ST67.872.884503×150+2×70/2+1×10ST71.576.596203×185+2×95/2+1×10ST76.381.3109808.7/15 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/352.656.640403×35+3×25/355.659.646303×50+3×25/358.962.953703×70+3×35/364.568.567203×95+3×50/368.272.278503×120+3×70/372.176.191303×150+3×70/377.681.6107503×185+3×95/381.585.5122903×25+2×25/2+1×10ST535741303×35+2×25/2+1×10ST55.659.647403×50+2×25/2+1×10ST59.363.354703×70+2×35/2+1×10ST64.668.668203×95+2×50/2+1×10ST68.373.379503×120+2×70/2+1×10ST74.479.492403×150+2×70/2+1×10ST78.183.1108603×185+2×95/2+1×10ST81.186.11240012/20 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/356.960.946203×35+3×25/359.963.952203×50+3×25/3656963003×70+3×35/368.972.974103×95+3×50/372.576.585603×120+3×70/378.282.2102603×150+3×70/381.985.9115703×185+3×95/387.492.4135303×25+2×25/2+1×10ST57.361.347703×35+2×25/2+1×10ST59.963.953403×50+2×25/2+1×10ST65.469.464603×70+2×35/2+1×10ST68.872.874503×95+2×50/2+1×10ST74.479.486803×120+2×70/2+1×10ST78.783.7103703×150+2×70/2+1×10ST82.287.2116503×185+2×95/2+1×10ST/25kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×10ST64.768.759403×35+2×25/2+1×10ST67.371.364703×50+2×25/2+1×10ST717573003×70+2×35/2+1×10ST75.280.288003×95+2×50/2+1×10ST8085100503×120+2×70/2+1×10ST85.990.9114703×150+2×70/2+1×10ST89.694.6132103×185+2×95/2+1×10ST92.697.61486018/30kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/369.573.566803×35+3×25/372.576.573803×50+3×25/377.681.684603×70+3×35/381.585.596903×95+3×50/384.989.9109603×120+3×70/390.695.6128303×150+3×70/394.399.3142503×185+3×95/×25+2×25/2+1×10ST69.973.971003×35+2×25/2+1×10ST72.676.675403×50+2×25/2+1×10ST788286803×70+2×35/2+1×10ST80.485.497603×95+2×50/2+1×10ST86.891.8111003×120+2×70/2+1×10ST91.196.1129803×150+2×70/2+1×10ST94.899.8143503×185+2×95/2+1×10ST99.6104.615870
Other supplier products
|
|
|
Cat 5e SF/UTP 24AWG 4P/8P IEC60092ApplicationThese Cat5e SF/UTP cables are manufactured in accordance with IEC 61156-5 requirements,Website:, can s... |
|
|
|
Industrial Cables H05V-KApplication and DescriptionThese insulated wires are determined for installation to tde inside of apparatus as well as for ... |
|
|
|
450/750V XLPE Insulated,Website:, PVC Sheathed, Screened Power Cables (Multicore) CU/XLPE/CUTO/PVC 450/750V Class 2Application:The cables are mainl... |
|
|
|
VDE Standard Industrial Cables H05Z-U/H07Z-U/H07Z-RApplication and DescriptionThese cables are designed for the internal wiring of switchboards and... |
|
|
|
Multipair Individually Screened Cables-Belden Equivalent 8776,Website:, UL2919ApplicationsThese cables have individually screened pairs laid up. Ea... |
供应产品
Same products