(N)TSCGEWOEU Medium-Voltage Fixed Installation Cable With Fiber Optics

(N)TSCGEWOEU Medium-Voltage Fixed Installation Cable With Fiber OpticsApplicationsThese cables are used for For laying alongside the conveyor belts (also for shiftable units)and on material handling equipment (even with continuous movementsuch as in cable booms or as connection between upperand lower car) and for connection of submersible pump units.StandardsBased on VDE 0250 Part 813ConstructionConductorsFlexible strandedcopper conductor,Website:, class 5 according to DIN VDE 0295.Inner Conductor LayerSemiconductive layer.InsulationEPR.Outer Conductor LayerSemiconductive layer.Earth ConductorSplit into two in the outer interstices.Fiber OpticsFO 50/125 or 62.5/125 orE9/125μm within protection sheath.InnerSheathEPR.Outer SheathCM.Dimensions and Weight3.6/6 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×(6LWL)40.143.126503×25+2×50/2+1×(6LWL)42.445.430603×35+2×25/2+1×(6LWL)42.345.330603×35+2×50/2+1×(6LWL)44.047.034103×50+2×25/2+1×(6LWL)43.846.834903×50+2×50/2+1×(6LWL)46.149.136403×70+2×35/2+1×(6LWL)47.050.043503×70+2×50/2+1×(6LWL)52.056.052803×95+2×50/2+1×(6LWL)52.256.255503×120+2×70/2+1×(6LWL)49.650.970403×150+2×70/2+1×(6LWL)48.452.380003×185+2×95/2+1×(6LWL)51.355.393103×240+2×120/2+1×(6LWL)58.062.0119403×300+2×150/2+1×(6LWL)63.267.2142306/10 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×(6LWL)41.444.427703×25+2×50/2+1×(6LWL)43.146.131203×35+2×25/2+1×(6LWL)43.646.631903×35+2×50/2+1×(6LWL)44.747.734703×50+2×25/2+1×(6LWL)45.148.136203×50+2×50/2+1×(6LWL)46.849.840103×70+2×35/2+1×(6LWL)48.351.345003×70+2×50/2+1×(6LWL)52.756.753603×95+2×50/2+1×(6LWL)53.557.557103×120+2×70/2+1×(6LWL)57.261.268303×150+2×70/2+1×(6LWL)62.366.381803×185+2×95/2+1×(6LWL)65.369.395003×240+2×120/2+1×(6LWL)73.477.4121603×300+2×150/2+1×(6LWL)78.682.6144608.7/15 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×(6LWL)44.247.230503×25+2×50/2+1×(6LWL)45.448.433503×35+2×25/2+1×(6LWL)45.348.333203×35+2×50/2+1×(6LWL)47.050.037103×50+2×25/2+1×(6LWL)49.453.441603×50+2×50/2+1×(6LWL)51.255.245903×70+2×35/2+1×(6LWL)52.756.750803×70+2×50/2+1×(6LWL)55.059.056403×95+2×50/2+1×(6LWL)57.061.061603×120+2×70/2+1×(6LWL)62.166.175203×150+2×70/2+1×(6LWL)65.769.786703×185+2×95/2+1×(6LWL)68.772.7100103×240+2×120/2+1×(6LWL)76.880.8127303×300+2×150/2+1×(6LWL)82.086.01508012/20 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×(6LWL)45.548.531403×25+2×50/2+1×(6LWL)47.250.235303×35+2×25/2+1×(6LWL)48.351.336403×35+2×50/2+1×(6LWL)51.055.042403×50+2×25/2+1×(6LWL)52.556.545303×50+2×50/2+1×(6LWL)52.556.546903×70+2×35/2+1×(6LWL)55.759.754603×70+2×50/2+1×(6LWL)58.062.060403×95+2×50/2+1×(6LWL)61.465.467703×120+2×70/2+1×(6LWL)65.169.179503×150+2×70/2+1×(6LWL)68.772.791303×185+2×95/2+1×(6LWL)73.277.2107703×240+2×120/2+1×(6LWL)79.883.8132603×300+2×150/2+1×(6LWL)86.391.31604014/25 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×(6LWL)50.354.337403×25+2×50/2+1×(6LWL)50.354.339003×35+2×25/2+1×(6LWL)53.157.142703×35+2×50/2+1×(6LWL)53.157.144403×50+2×25/2+1×(6LWL)56.360.350003×50+2×50/2+1×(6LWL)56.360.351603×70+2×35/2+1×(6LWL)61.065.061903×70+2×50/2+1×(6LWL)61.065.063903×95+2×50/2+1×(6LWL)65.369.373403×120+2×70/2+1×(6LWL)69.073.085503×150+2×70/2+1×(6LWL)74.078.0100203×185+2×95/2+1×(6LWL)77.081.0114103×240+2×120/2+1×(6LWL)85.090.0143803×300+2×150/2+1×(6LWL)90.295.21682018/30 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×(6LWL)53.757.741403×25+2×50/2+1×(6LWL)53.757.743103×35+2×25/2+1×(6LWL)56.660.647203×35+2×50/2+1×(6LWL)56.660.648803×50+2×25/2+1×(6LWL)61.265.256803×50+2×50/2+1×(6LWL)61.265.258403×70+2×35/2+1×(6LWL)64.468.466703×70+2×50/2+1×(6LWL)64.468.468703×95+2×50/2+1×(6LWL)68.772.778603×120+2×70/2+1×(6LWL)73.877.893503×150+2×70/2+1×(6LWL)77.581.5106303×185+2×95/2+1×(6LWL)80.584.5120403×240+2×120/2+1×(6LWL)88.593.5150703×300+2×150/2+1×(6LWL)94.799.717780
Other supplier products
|
|
|
Multicore Unscreened Armoured Cables-Belden Equivalent 26503ApplicationsThese multipair overall screened armoured cables provide excellent protecti... |
|
|
|
Flame Retardant CAT6 CWB/SWB/SWA Armoured Data Cables CAT6 U/UTP4P23CAT6 F/UTP4P23CAT6 SF/FTP4P23Application:Cat6 Cable is a cable standard for Gig... |
|
|
|
450/750V XLPE Insulated,Website:, PVC Sheathed, Screened Power Cables (Multicore) CU/XLPE/CUTO/PVC 450/750V Class 2Application:The cables are mainl... |
|
|
|
P7 or P7/P14 BFOU 6/10kV Fire resistant NEK606 MV cableApplications :These cables are fire resistant,Website:, flame retardant, low smoke, halogen ... |
|
|
|
Fire resistant Central Loose Tube Fiber Optic cables FR200P 05M2XSH-R (CU/MICA+XLPE/OS/LSZH 300/500V Class 2 )Application:These cables are characte... |