(N)TSCGEWOEU Medium-Voltage Fixed Installation Cable With Fiber Optics

(N)TSCGEWOEU Medium-Voltage Fixed Installation Cable With Fiber OpticsApplicationsThese cables are used for For laying alongside the conveyor belts (also for shiftable units)and on material handling equipment (even with continuous movementsuch as in cable booms or as connection between upperand lower car) and for connection of submersible pump units.StandardsBased on VDE 0250 Part 813ConstructionConductorsFlexible strandedcopper conductor,Website:, class 5 according to DIN VDE 0295.Inner Conductor LayerSemiconductive layer.InsulationEPR.Outer Conductor LayerSemiconductive layer.Earth ConductorSplit into two in the outer interstices.Fiber OpticsFO 50/125 or 62.5/125 orE9/125μm within protection sheath.InnerSheathEPR.Outer SheathCM.Dimensions and Weight3.6/6 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×(6LWL)40.143.126503×25+2×50/2+1×(6LWL)42.445.430603×35+2×25/2+1×(6LWL)42.345.330603×35+2×50/2+1×(6LWL)44.047.034103×50+2×25/2+1×(6LWL)43.846.834903×50+2×50/2+1×(6LWL)46.149.136403×70+2×35/2+1×(6LWL)47.050.043503×70+2×50/2+1×(6LWL)52.056.052803×95+2×50/2+1×(6LWL)52.256.255503×120+2×70/2+1×(6LWL)49.650.970403×150+2×70/2+1×(6LWL)48.452.380003×185+2×95/2+1×(6LWL)51.355.393103×240+2×120/2+1×(6LWL)58.062.0119403×300+2×150/2+1×(6LWL)63.267.2142306/10 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×(6LWL)41.444.427703×25+2×50/2+1×(6LWL)43.146.131203×35+2×25/2+1×(6LWL)43.646.631903×35+2×50/2+1×(6LWL)44.747.734703×50+2×25/2+1×(6LWL)45.148.136203×50+2×50/2+1×(6LWL)46.849.840103×70+2×35/2+1×(6LWL)48.351.345003×70+2×50/2+1×(6LWL)52.756.753603×95+2×50/2+1×(6LWL)53.557.557103×120+2×70/2+1×(6LWL)57.261.268303×150+2×70/2+1×(6LWL)62.366.381803×185+2×95/2+1×(6LWL)65.369.395003×240+2×120/2+1×(6LWL)73.477.4121603×300+2×150/2+1×(6LWL)78.682.6144608.7/15 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×(6LWL)44.247.230503×25+2×50/2+1×(6LWL)45.448.433503×35+2×25/2+1×(6LWL)45.348.333203×35+2×50/2+1×(6LWL)47.050.037103×50+2×25/2+1×(6LWL)49.453.441603×50+2×50/2+1×(6LWL)51.255.245903×70+2×35/2+1×(6LWL)52.756.750803×70+2×50/2+1×(6LWL)55.059.056403×95+2×50/2+1×(6LWL)57.061.061603×120+2×70/2+1×(6LWL)62.166.175203×150+2×70/2+1×(6LWL)65.769.786703×185+2×95/2+1×(6LWL)68.772.7100103×240+2×120/2+1×(6LWL)76.880.8127303×300+2×150/2+1×(6LWL)82.086.01508012/20 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×(6LWL)45.548.531403×25+2×50/2+1×(6LWL)47.250.235303×35+2×25/2+1×(6LWL)48.351.336403×35+2×50/2+1×(6LWL)51.055.042403×50+2×25/2+1×(6LWL)52.556.545303×50+2×50/2+1×(6LWL)52.556.546903×70+2×35/2+1×(6LWL)55.759.754603×70+2×50/2+1×(6LWL)58.062.060403×95+2×50/2+1×(6LWL)61.465.467703×120+2×70/2+1×(6LWL)65.169.179503×150+2×70/2+1×(6LWL)68.772.791303×185+2×95/2+1×(6LWL)73.277.2107703×240+2×120/2+1×(6LWL)79.883.8132603×300+2×150/2+1×(6LWL)86.391.31604014/25 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×(6LWL)50.354.337403×25+2×50/2+1×(6LWL)50.354.339003×35+2×25/2+1×(6LWL)53.157.142703×35+2×50/2+1×(6LWL)53.157.144403×50+2×25/2+1×(6LWL)56.360.350003×50+2×50/2+1×(6LWL)56.360.351603×70+2×35/2+1×(6LWL)61.065.061903×70+2×50/2+1×(6LWL)61.065.063903×95+2×50/2+1×(6LWL)65.369.373403×120+2×70/2+1×(6LWL)69.073.085503×150+2×70/2+1×(6LWL)74.078.0100203×185+2×95/2+1×(6LWL)77.081.0114103×240+2×120/2+1×(6LWL)85.090.0143803×300+2×150/2+1×(6LWL)90.295.21682018/30 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+2×25/2+1×(6LWL)53.757.741403×25+2×50/2+1×(6LWL)53.757.743103×35+2×25/2+1×(6LWL)56.660.647203×35+2×50/2+1×(6LWL)56.660.648803×50+2×25/2+1×(6LWL)61.265.256803×50+2×50/2+1×(6LWL)61.265.258403×70+2×35/2+1×(6LWL)64.468.466703×70+2×50/2+1×(6LWL)64.468.468703×95+2×50/2+1×(6LWL)68.772.778603×120+2×70/2+1×(6LWL)73.877.893503×150+2×70/2+1×(6LWL)77.581.5106303×185+2×95/2+1×(6LWL)80.584.5120403×240+2×120/2+1×(6LWL)88.593.5150703×300+2×150/2+1×(6LWL)94.799.717780
Other supplier products
|
|
|
S12 RU(c) 250 V EPR insulation,Website:, SHF2 sheathed NEK606 Instrument cableApplications :These unarmoured cables are flame retardant, low smoke ... |
|
|
|
Multipair Individually Screened Cables-Belden Equivalent 8773,Website:, UL2919ApplicationsThese cables have individually screened pairs laid up. Ea... |
|
|
|
S11 RU(i) 250 V Individual Shielding,Website:, SHF2 Sheathed NEK606 Instrument cableApplications :These unarmoured cables are flame retardant, low ... |
|
|
|
3.8/6.6kV,Website:, 6.35/11kV, 8.7/15kV HF-EPR Insulated, SW2/SW4 Sheathed Unarmoured Flame Retardant Power & Control CablesApplication:These mediu... |
|
|
|
Multipair Individually and Overall Screened Cables-Belden Equivalent 8185ApplicationsThese cables have individually screened pairs laid up in a foi... |