0.6/1kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Fire Resistant Power Control Cables

0.6/1kV HF-EPR Insulated,Website:, SW2/SW4 Sheathed Armoured Fire Resistant Power & Control CablesApplication:These fire resistant elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications where fire integrity is essential.Standards:BS 7917IEC 60331-31 Fire resistantIEC 60332-3A Flame retardantIEC 60754-1; IEC 60754-2 CorrosivityIEC 61034-2 Smoke densityCold bend and impact (-40°C) (on request)CSA C22.2 No. 38-95 (on request)Construction:Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.Insulation: Mica tape + HF-EPR GP4 according to BS 7655 1.2.Inner Sheath: Halogen free thermosetting compound SB1 according to BS 7917.Armour: Galvanized steel wire braid or tinned bronze wire braid (single core). Copper wire braid can be offered upon request.Outer Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.Mechanical and Thermal Properties:Minimum Internal Bending Radius: 6×ODTemperature Range: -40℃ ~ +90℃Dimensions and WeightSingle core cablesConstruction No. of cores×Cross section(mm2)Nominal Insulation Thickness mmNominal Inner Sheath Thickness mmMinimum Diameter Over Inner Sheath mmMaximum Diameter Over Inner Sheath mmNominal Armour Wire Diameter mmNominal Outer Sheath Thickness mmMinimum Overall Diameter mmMaximum Overall Diameter mmApprox. Weight kg/km1×41.01.06.78.00.31.110.212.12451×61.01.07.28.50.31.110.812.62751×101.01.08.19.50.31.211.913.83551×161.01.19.310.70.31.213.115.04401×251.21.211.513.20.31.315.417.76001×351.21.212.314.10.31.416.518.87201×501.41.314.115.90.31.418.220.69101×701.41.315.817.80.31.520.223.011701×951.61.418.120.20.31.622.625.615101×1201.61.520.022.40.31.724.727.718301×1501.81.622.024.60.31.826.930.121601×1852.01.724.427.00.451.930.233.927901×2402.21.827.530.30.452.033.537.335301×3002.41.930.433.60.452.136.640.54280Multicore cablesConstruction No. of cores×Cross section(mm²)Nominal Insulation Thickness mmNominal Inner Sheath Thickness mmMinimum Diameter Over Inner Sheath mmMaximum Diameter Over Inner Sheath mmNominal Armour Wire Diameter mmNominal Outer Sheath Thickness mmMinimum Overall Diameter mmMaximum Overall Diameter mmApprox. Weight kg/km2×1.50.81.19.010.40.31.212.714.73102×2.50.81.19.811.40.31.213.615.53552×41.01.211.813.50.31.315.718.04752×61.01.212.914.60.31.417.019.35802×101.01.314.916.80.31.419.021.47502×161.01.417.119.10.31.521.424.39802×251.21.521.223.70.31.725.929.013802×351.21.623.125.70.31.828.031.217102×501.41.726.529.20.452.032.536.323702×701.41.930.333.50.452.136.540.531002×951.62.134.938.20.452.341.446.040202×1201.62.238.442.20.452.545.450.148703×1.50.81.19.611.00.31.213.315.33453×2.50.81.110.412.10.31.314.416.44053×41.01.212.614.30.31.316.518.85403×61.01.213.815.50.31.417.920.26603×101.01.315.917.80.31.520.223.09103×161.01.418.220.30.31.622.825.712003×251.21.622.925.40.31.827.830.917603×351.21.724.927.60.451.930.734.422603×501.41.828.531.30.452.034.538.428803×701.42.032.735.90.452.239.043.538003×951.62.237.541.00.452.444.348.948903×1201.62.341.345.30.452.648.553.760703×1501.82.545.849.90.452.853.358.772703×1852.02.750.955.50.453.058.864.989703×2402.22.957.562.40.453.265.872.213504×1.50.81.110.512.10.31.314.416.43954×2.50.81.111.413.10.31.315.417.64654×41.01.213.815.60.31.417.920.36404×61.01.315.317.30.31.519.622.57904×101.01.417.719.70.31.622.225.110704×161.01.520.322.80.31.725.028.114604×251.21.725.528.10.451.931.335.021404×351.21.827.730.50.452.033.737.526704×501.41.931.835.00.452.238.142.136304×701.42.136.339.70.452.443.147.747404×951.62.341.745.70.452.648.954.162904×1201.62.546.250.30.452.853.759.276705×1.50.81.111.413.10.31.315.417.64557×1.50.81.212.614.40.31.316.618.953012×1.50.81.316.818.80.31.521.224.079019×1.50.81.419.922.40.31.624.427.5108027×1.50.81.624.326.90.31.829.232.8146037×1.50.81.727.430.40.451.933.237.019905×2.50.81.212.714.40.31.316.618.95607×2.50.81.213.915.60.31.418.020.365012×2.50.81.418.720.80.31.623.226.297019×2.50.81.522.124.70.31.726.830.01360
Other supplier products
|
|
|
Type 209 1.1 to 11KV to AS/NZS 1802ApplicationsType 209 series cable is mainly used as a flexible feeder to machinery,Website:, more suitable as a ... |
|
|
|
Fire resistant RG6 QUAD Coaxial cables RG6 QUAD FRApplication:The cables are designed for CCTV,Website:, security, smoke detection and evacuation m... |
|
|
|
Type SHD-GC Three-Conductor Round Portable Power Cable,Website:, TPU Jacket 5kV ICEA S-75-381ApplicationsThese heavy duty cables are designed for h... |
|
|
|
Armoured Cat 5e SF/UTP 24AWG IEC60092ApplicationThese Cat5e SF/UTP cables are manufactured in accordance with IEC 61156-5 requirements,Website:, ca... |
|
|
|
250V [FA-] TTY-S,Website:, TTYC-S, TTYCY-S [FA-] TTPY-S, TTPYC-S, TTPYCY-SStandards:JISC 3410-1999IEC 60332-1IEC 60332-3 Cat.A(for FA-type)CABLE CO... |