0.6/1kV HF-EPR Insulated, SW2/SW4 Sheathed Unarmoured Fire Resistant Power Control Cables

0.6/1kV HF-EPR Insulated,Website:, SW2/SW4 Sheathed Unarmoured Fire Resistant Power & Control CablesApplication:These fire resistant elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications where fire integrity is essential.Standards:BS 7917IEC 60331-31 Fire resistantIEC 60332-3A Flame retardantIEC 60754-1; IEC 60754-2 CorrosivityIEC 61034-2 Smoke densityCold bend and impact (-40°C) (on request)CSA C22.2 No. 38-95 (on request)Construction:Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.Insulation: Mica tape + HF-EPR GP4 according to BS 7655 1.2.Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.Mechanical and Thermal Properties:Minimum Internal Bending Radius: 6×OD (OD>25mm); 4×OD (OD ≤25mm)
Temperature Range: -40℃ ~ +90℃Dimensions and WeightSingle core cablesConstruction No. of cores×Cross section(mm²)Nominal Insulation Thickness mmNominal Sheath Thickness mmMinimum Overall Diameter mmMaximum Overall Diameter mmApprox. Weight kg/km1×41.01.06.78.0901×61.01.07.28.51351×101.01.08.19.51801×161.01.19.310.73151×251.21.211.513.25501×351.21.212.314.17151×501.41.314.115.98301×701.41.315.817.811101×951.61.418.120.214701×1201.61.520.022.421301×1501.81.622.024.624751×1852.01.724.427.028701×2402.21.827.530.331201×3002.41.930.433.64060Multicore cablesConstruction No. of cores×Cross section(mm²)Nominal Insulation Thickness mmNominal Sheath Thickness mmMinimum Overall Diameter mmMaximum Overall Diameter mmApprox. Weight kg/km2×1.50.81.19.010.41452×2.50.81.19.811.41802×41.01.211.813.52602×61.01.212.914.63252×101.01.314.916.84452×161.01.417.119.16302×251.21.521.223.79302×351.21.623.125.712102×501.41.726.529.216302×701.41.930.333.522102×951.62.134.938.230102×1201.62.238.442.236903×1.50.81.19.611.01703×2.50.81.110.412.12103×41.01.212.614.33103×61.01.213.815.53953×101.01.315.917.85903×161.01.418.220.38303×251.21.622.925.412703×351.21.724.927.615403×501.41.828.531.321003×701.42.032.735.928703×951.62.237.541.039103×1201.62.341.345.348003×1501.82.545.849.958103×1852.02.750.955.572903×2402.22.957.562.494404×1.50.81.110.512.12004×2.50.81.111.413.12504×41.01.213.815.63754×61.01.315.317.34954×101.01.417.719.77404×161.01.520.322.810504×251.21.725.528.115804×351.21.827.730.519604×501.41.931.835.025704×701.42.136.339.735304×951.62.341.745.748504×1201.62.546.250.359905×1.50.81.111.413.12207×1.50.81.212.614.428512×1.50.81.316.818.846519×1.50.81.419.922.468027×1.50.81.624.326.996037×1.50.81.727.430.412605×2.50.81.212.714.43107×2.50.81.213.915.637512×2.50.81.418.720.861019×2.50.81.522.124.7895
Other supplier products
|
|
|
300/500V Mica+XLPE Insulated,Website:, LSZH Sheathed fire resistant Power Cables (Single Core)(CU/MGT+XLPE/LSZH 300/500V Class 2)Application:These ... |
|
|
|
P16 IFLI 250 V XLPE Insulation,Website:, Armour&Metal Screen NEK606 CableApplications :These cables are flame retardant, low smoke and halogen free... |
|
|
|
450/750V LSZH Sheathed,Website:, Screened (2-4cores) Application:The cables are mainly used in power stations, mass transit underground passenger s... |
|
|
|
German Standard Industrial Cables H05G-U/H07G-U/RApplication and DescriptionThese cables are recommended for the internal wiring of switchboards an... |
|
|
|
BS5308 Part1 Instrumentation Cable Polyethylene InsulatedVDE Ref CodePVC Sheath VersionRE-2Y(St)Y (Overall Screen)RE-2Y(St)Y PiMF(Individual Screen... |
供应产品