P3 Or P3/P10 RFOU/TFOU 6/10KV NEK606 Cable

P3 or P3/P10 RFOU/TFOU 6/10KV NEK606 MV CableApplicationsThese cables are flame retardant,Website:, low smoke, halogen free and mud resistant, used for fixed installation for medium voltage power.StandardsIEC 60092-354; IEC 60092-351; IEC 60092-359; IEC 60332-1; IEC 60332-3-22; IEC 60754-1,2; IEC 61034-1,2; NEK 606:2004ConductorsCircular tinned annealed stranded copper to IEC 60228 class 2.Conductor ScreenSemi conducting material.InsulationHalogen-free EPR. XLPE can be offered as an option (for TFOU cable).Insulation ScreenSemi conducting material and tinned copper wire braid.BeddingHalogen free compound.ArmourTinned copper wire braid.Outer SheathHalogen free thermosetting compound, SHF2 (for TYPE P3), or halogen free mud resistant thermosetting compound, SHF MUD (for TYPE P3/P10),coloured red.Electrical CharacteristicsNominal Cross Section Areamm²Nominal Conductor Diametermm5.26.57.48.710.312.213.8Maximum DC Current Rating@45℃1 CoreAContinuous Current Rating@45℃3 CoreAShort Circuit Current 1sAOperating VoltageKV6/106/106/106/106/106/106/10Nominal Cross Section Areamm²Nominal Conductor Diametermm15.117.019.621.924.527.532.3Maximum DC Current Rating@45℃1 CoreAContinuous Current Rating@45℃3 CoreAShort Circuit Current 1sAOperating VoltageKV6/106/106/106/106/106/106/10Ambient Temperature Correction FactorsAmbient Temperature Correction FactorsRating Factor1.11.051.00.940.880.820.740.670.580.47Mechanical and Thermal PropertiesBending Radius 15×OD (during installation); 9×OD (fixed installed).Temperature Range -20℃ ~ +90℃.Dimensions and WeightConstruction No. of cores×Cross section(mm2)Nominal Insulation ThicknessmmNominal Sheath ThicknessmmNominal Overall DiametermmNominal Weightkg/kmInnerOuter1×163.41.51.124.09001×253.41.51.226.011401×353.41.61.226.912651×503.41.61.228.314601×703.41.71.330.017101×953.41.81.332.020601×1203.41.81.433.823801×1503.41.91.435.327001×1853.42.01.537.832251×2403.42.11.641.039901×3003.42.21.643.747601×4003.42.31.745.559001×5003.42.41.849.573501×6303.42.61.954.587503×163.42.31.746.033003×253.42.41.850.139053×353.42.51.852.243603×503.42.61.955.151853×703.42.72.058.961253×953.42.92.163.575003×1203.43.02.267.687753×1503.43.22.371.7102353×1853.43.42.474.0113003×2403.43.62.679.5133003×3003.43.82.785.016300
Other supplier products
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8115ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |
|
|
|
BS5308 Part1 Instrumentation Cable Polyethylene InsulatedVDE Ref CodePVC Sheath VersionRE-2Y(St)Y (Overall Screen)RE-2Y(St)Y PiMF(Individual Screen... |
|
|
|
150/250V Mica Tape + XLPE Insulated,Website:, LSOH (SHF1) Sheathed Flame Resistant Instrumentation & Control Cables (Multicore)ApplicationThese cab... |
|
|
|
VDE Standard Industrial Cables H03VV-F/H03VVH2-F pplication and DescriptionThese cable types are especially suited for use on small appliances with... |
|
|
|
PE Insulated,Website:, LSZH Sheathed & Overall Screened Instrumentation Cables (Single Triple)RE-2Y(St)H 90°C / 300 VSTANDARDSBasic design to EN5... |