3.6 6kV 6 10kV 8.7 15kV IEC60092 MV Cable
3.6/6kV,Website:, 6/10kV, 8.7/15kV XLPE Insulated, LSOH (SHF1) Sheathed, Armoured Flame Retardant MV Power Cables (Halogen Free Inner Covering)ApplicationThese armoured MV cables are used on board of ships in all locations for fixed installations complying with IEC standards 60092-352. These cables are flame retardant, low smoke& halogen free.StandardsIEC 60092-350/351/354/359IEC 60332-1IEC 60332-3-22IEC 60754-1/2IEC 61034ConstructionConductorsClass 2 stranded copper conductor.Conductor ScreenSemi-conducting layer (tape/compound).InsulationXLPE.Insulation ScreenSemi-conducting layer (tape/compound).Metallic ScreenCopper tapeInner CoveringHalogen free compound.ArmourCopper wire braid.Outer SheathLSOH (SHF1). SHF2 can be offered upon request.Core IdentificationColoured tape shall be inserted under metallic screen.3core: Red, Yellow, Blue.Mechanical and Thermal PropertiesBending Radius for Fixed Installations: 12×OD (single core); 9×OD (three core) Temperature Range: -30℃ ~ +80℃Dimensions and Weight3.6/6kVPart No.ConstructionNo. of cores×Crosssection(mm²)Nominal InsulationThickness mmNominal Sheath Thickness mmNominal OverallDiameter mmNominal Weight kg/km3.6/6KV-1C101×102.51.519.65803.6/6KV--1C161×162.51.520.56703.6/6KV-1C251×252.51.521.88003.6/6KV-1C351×352.51.623.29403.6/6KV-1C501×502.51.624.511003.6/6KV-1C701×702.51.726.513803.6/6KV-1C951×952.51.828.617003.6/6KV-1C1201×1202.51.930.420003.6/6KV-1C1501×1502.51.932.023203.6/6KV-1C1851×1852.52.034.427703.6/6KV-1C2401×2402.62.138.035303.6/6KV-1C3001×3002.82.341.242703.6/6KV-1C4001×4003.02.445.654103.6/6KV-1C5001×5003.22.548.963903.6/6KV-1C6301×6303.22.753.580303.6/6KV-3C103×102.52.035.416203.6/6KV-3C163×162.52.238.420303.6/6KV-3C253×252.52.341.424703.6/6KV-3C353×352.52.444.229303.6/6KV-3C503×502.52.547.635103.6/6KV-3C703×702.52.751.943903.6/6KV-3C953×952.52.856.654703.6/6KV-3C1203×1202.53.060.464503.6/6KV-3C1503×1502.53.164.174903.6/6KV-3C1853×1852.53.368.388503.6/6KV-3C2403×2402.63.575.4110806/10kVPart No.ConstructionNo. of cores×Crosssection(mm²)Nominal InsulationThickness mmNominal Sheath Thickness mmNominal OverallDiameter mmNominal Weight kg/km6/10KV-1C161×163.41.622.57506/10KV-1C251×253.41.623.88906/10KV-1C351×353.41.725.210406/10KV-1C501×503.41.726.512006/10KV-1C701×703.41.828.514806/10KV-1C951×953.41.930.618106/10KV-1C1201×1203.41.932.221006/10KV-1C1501×1503.42.034.424706/10KV-1C1851×1853.42.136.929806/10KV-1C2401×2403.42.239.836506/10KV-1C3001×3003.42.342.443406/10KV-1C4001×4003.42.546.654806/10KV-1C5001×5003.42.649.564306/10KV-1C6301×6303.42.753.980406/10KV-3C163×163.42.342.523306/10KV-3C253×253.42.445.928406/10KV-3C353×353.42.548.733106/10KV-3C503×503.42.751.938906/10KV-3C703×703.42.856.448206/10KV-3C953×953.43.060.859006/10KV-3C1203×1203.43.164.568806/10KV-3C1503×1503.43.368.379606/10KV-3C1853×1853.43.472.893906/10KV-3C2403×2403.43.779.2115708.7/15kVPart No.ConstructionNo. of cores×Crosssection(mm²)Nominal InsulationThickness mmNominal Sheath Thickness mmNominal OverallDiameter mmNominal Weight kg/km8.7/15KV-1C251×254.51.726.210208.7/15KV-1C351×354.51.827.611708.7/15KV-1C501×504.51.828.913408.7/15KV-1C701×704.51.930.916308.7/15KV-1C951×954.52.033.420008.7/15KV-1C1201×1204.52.035.023008.7/15KV-1C1501×1504.52.137.327308.7/15KV-1C1851×1854.52.239.331808.7/15KV-1C2401×2404.52.342.238608.7/15KV-1C3001×3004.52.445.246008.7/15KV-1C4001×4004.52.548.856908.7/15KV-1C5001×5004.52.751.966808.7/15KV-1C6301×6304.52.856.783608.7/15KV-3C253×254.52.651.032808.7/15KV-3C353×354.52.753.837708.7/15KV-3C503×504.52.957.444308.7/15KV-3C703×704.53.061.553408.7/15KV-3C953×954.53.266.064608.7/15KV-3C1203×1204.53.369.674608.7/15KV-3C1503×1504.53.573.986408.7/15KV-3C1853×1854.53.678.0100408.7/15KV-3C2403×2404.53.984.412270
Other supplier products
|
|
Fire Resistant UTP CAT5 Data Cables FR-CAT5UTP4P24Application:The cables are desgined for structure wiring,Website:, compatible with all known conn... |
|
|
Multipair Individually Screened Cables-Belden Equivalent 9733ApplicationsThese cables have individually screened pairs laid up. Each individually s... |
|
|
S11 RU(i) 250 V Individual Shielding,Website:, SHF2 Sheathed NEK606 Instrument cableApplications :These unarmoured cables are flame retardant, low ... |
|
|
German Standard Industrial Cables LiHCH TPApplication and DescriptionLiHCH TP is for use in flexible or stationary applications under low mechanica... |
|
|
German Standard Industrial Cables N2XFGY/ NA2XFGYApplication and DescriptionN2XFGY/ NA2XFGY cables are for lying in eartd,Website:, indoors, in duc... |
供应产品
Same products