Armoured Cat 6 S/FTP 23AWG

Armoured Cat 6 S/FTP 23AWG IEC60092ApplicationThese Cat6 S/FTP cables are manufactured in accordance with IEC 61156-5 requirements,Website:, can support all Class E applications like Ethernet, Fast Ethernet, Gigabit Ethernet, suitable for basic voice and data installations up to 250MHz.StandardsEN 50288ISO 11801IEC 61156-5IEC 60332-1IEC 60754-1/2IEC 61034ConstructionConductorsSolid bare copper conductor.InsulationPE.TwinningTwo coloured insulated conductors twisted together to form a pair.Individual ScreenAl/polyester tape.Overall ScreenTinned copper braid.Inner SheathLSOH.ArmourTinned copper braid.Outer SheathLSOH (SHF1).Core IdentificationPair 1: White, Blue
Pair 2: White, Orange
Pair 3: White, Green
Pair 4: White, BrownElectrical PropertiesMaximum DC Loop ResistanceΩ/km165Maximum Resistance Unbalance2%Minimum Insulation ResistanceMΩ.km1000Nominal Capacitance @800HznF/km43Maximum Capacitance Unbalance (pair to ground)pF/km1500Characteristic Impedance @1-100MHzΩ100 ± 15Nominal Velocity of Propagation79%Maximum Propagation Delayns/100 m427Maximum Delay Skewns/100 m12Maximum Transfer Impedance @1MHzmΩ /m5Maximum Transfer Impedance @10MHzmΩ /m10Maximum Transfer Impedance @30MHzmΩ /m30Maximum Transfer Impedance @100MHzmΩ /m100Nominal Transmission Characteristics @20℃FAttenuationNEXTPS-NEXTACRPS-ACRELFEXTPS-ELFEXTReturn LossMHzdB/100mdBdBdB/100mdB/100mdB/100mdB/100mdB12......2510..5014.......Mechanical and Thermal PropertiesBending Radius: 8×OD (during installation); 4×OD (fixed installed)Temperature Range: -20℃ ~ +60℃Dimensions and WeightPart No.ConstructionNo. of elements×No. of cores in element×Crosssection(mm²)NominalInsulation Thickness mmNominal Sheath Thickness mmNominalOverall Diameter mmNominal Weight kg/kmInnerOuterUE092-S/FTPCAT6A4P234×2×23AWG0.5780.601.0910.78188
Other supplier products
|
|
|
150/250V HF-EPR Insulated,Website:, SW2/SW4 Sheathed, Collectively Screened Unarmoured Flame Retardant Instrumentation & Control CablesApplication:... |
|
|
|
Type 2S 1.1/1.1KV & 3.3/3.3KV Individually ScreenedApplicationsThese individually copper screened cables are used for wiring of machines or between... |
|
|
|
S1 or S1/S5 RFOU(i) 250V Individual Shielding &Armour NEK606 Instrument cableApplications :These cables are flame retardant,Website:, low smoke, ha... |
|
|
|
Flame Retardant CAT6 CWB/SWB/SWA Armoured Data Cables CAT6 U/UTP4P23CAT6 F/UTP4P23CAT6 SF/FTP4P23Application:Cat6 Cable is a cable standard for Gig... |
|
|
|
Multipair Individually Screened Cables-Belden Equivalent 9776,Website:, UL2919ApplicationsThese cables have individually screened pairs laid up. Ea... |