S11 RU(i) 250 V NEK606 Cable

S11 RU(i) 250 V Individual Shielding,Website:, SHF2 Sheathed NEK606 Instrument cableApplications :These unarmoured cables are flame retardant, low smoke and halogen free, used for instrumentation, communication, control and alarm systems.Standards :IEC 60092-376IEC 60092-351IEC 60092-359IEC 60332-1IEC 60332-3-22IEC 60754-1,2IEC 61034-1,2NEK 606:2004Conductors :Circular tinned annealed stranded copper wire to IEC 60228 class 2.Insulation :Halogen free EPR compound.Twinning :Colour coded cores twisted together.Individual Shielding :Each pairs/triples are screened by copper backed polyester tape in contact with a stranded tinned copper drain wire and wrapped with polyester tape.Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors.Outer Sheath :Halogen free thermosetting compound, SHF2, coloured grey (blue for intrinsically safe).Electrical Characteristics : Nominal Cross Section Areamm²0.751.01.52.5Nominal Conductor Diametermm1.11.31.62.0Maximum CapacitancenF/kmNominal L/R@1KHzμH/Ω20253550Operating VoltageVMechanical and Thermal Properties : Bending Radius : 8×OD (during installation); 6×OD (fixed installed). Temperature Range : -20℃ ~ +90℃. Dimensions and Weight :Construction No. of elements×No. of cores in element×Cross section
(mm²)Nominal Insulation Thickness mmNominal Sheath Thickness mmNominal Overall Diameter mmNominal Weight kg/km1×2×0.750.61.07.6952×2×0.750.61.19.71804×2×0.750.61.212.12557×2×0.750.61.314.43808×2×0.750.61.315.642512×2×0.750.61.519.061016×2×0.750.61.521.078519×2×0.750.61.622.489524×2×0.750.61.725.6113532×2×0.750.61.828.414401×3×0.750.61.08.01102×3×0.750.61.211.01803×3×0.750.61.212.72654×3×0.750.61.213.83257×3×0.750.61.416.75008×3×0.750.61.418.054012×3×0.750.61.622.281516×3×0.750.61.624.7104519×3×0.750.61.726.2120524×3×0.750.61.930.515451×2×1.00.61.08.11102×2×1.00.61.110.42154×2×1.00.61.212.93107×2×1.00.61.415.54758×2×1.00.61.417.054012×2×1.00.61.520.576016×2×1.00.61.522.999519×2×1.00.61.724.1113524×2×1.00.61.827.8145032×2×1.00.61.930.818501×3×1.00.61.08.51253×3×1.00.61.313.43204×3×1.00.61.314.83957×3×1.00.61.517.961512×3×1.00.61.623.799016×3×1.00.61.726.5129519×3×1.00.61.828.0147524×3×1.00.62.032.619001×2×1.50.71.09.11402×2×1.50.71.211.72804×2×1.50.71.314.94107×2×1.50.71.518.06358×2×1.50.71.519.772012×2×1.50.71.623.8101516×2×1.50.71.626.6133019×2×1.50.71.928.3152524×2×1.50.72.032.6194532×2×1.50.72.236.124751×3×1.50.71.09.51602×3×1.50.71.314.02853×3×1.50.71.315.54254×3×1.50.71.317.05257×3×1.50.71.620.98308×3×1.50.71.622.590012×3×1.50.71.827.6134016×3×1.50.71.931.1177019×3×1.50.72.032.8202024×3×1.50.72.238.426101×2×2.50.71.09.81751×3×2.50.71.210.4205
Other supplier products
|
|
|
Type MP-GC Three-Conductor Mine Power Feeder Cable,Website:, PVC Jacket, 8kV ICEA S-75-381ApplicationsThese cables are designed for connections bet... |
|
|
|
150/250V XLPE Insulated,Website:, LSOH (SHF1) Sheathed, Overall Screened & Armoured Flame Retardant Instrumentation & Control Cables (Multipair/Mul... |
|
|
|
450/750V XLPE Insulated,Website:, PVC Sheathed Power Cables (2-4 Cores) CU/XLPE/PVC 450/750V Class 2Application:The cables are mainly used in power... |
|
|
|
PE Insulated,Website:, LSZH Sheathed, Overall Screened & Armoured Instrumentation Cables (Multitriple)RE-2Y(St)HSWAH 70°C / 300 VSTANDARDSBasic des... |
|
|
|
0.6/1kV HF-EPR Insulated,Website:, SW2/SW4 Sheathed Unarmoured Fire Resistant Power & Control CablesApplication:These fire resistant elastomeric in... |