600 1000V PVC Insulated, Non-sheathed Power Cables (Single Core)

600/1000V PVC Insulated,Website:, Non-sheathed Power Cables (Single Core) (CU/PVC 600/1000V Class 2)Application:The cables are mainly used in power stations, mass transit underground passenger systems, airports, petrochemical plants, hotels, hospitals, and high-rise buildings.STANDARDS:Basic design adapted to BS 6491XFIRE PERFORMANCEFlame Retardance (Single Vertical Wire Test)**EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE *Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)**EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.VOLTAGE RATING600/1000VCABLE CONSTRUCTIONConductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2.Insulation: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.COLOUR CODEInsulation Colour as per BS7671With Earth ConductorWithout Earth Conductor2Cores-Brown, Blue3CoresYellow/Green, Brown, BlueBrown, Gray, Black4CoresYellow/Green, Brown, Gray, BlackBrown, Gray, Black, Blue5CoresYellow/Green, Brown, Gray, Black, BlueBrown, Gray, Black, Blue, BlackAbove 5 CoresYellow/Green, Black NumberedBlack NumberedSheath Colour: Black (other colors upon request)Physical AND THERMAL PROPERTIESTemperature range during operation: Max.90°C250°C in short-circuit for 5secs max.Minimum bending radius: 8 x Overall Diameter (unarmoured cable)10 x Overall Diameter (armoured cable)CONSTRUCTION PARAMETERSConductorNo. of Core X Cross SectionNo./Nominal Diameter of StrandsNominal Insulation ThicknessInsulated, Non-SheathedNominal Overall DiameterApprox. WeightNoxmm2No./mmmmmmkg/km1x1.57/0.530.73.1221x2.57/0.670.83.7341x47/0.850.84.3501x67/1.040.84.8701x107/1.351.06.21161x167/1.701.07.21741x257/2.141.29.02761x357/2.521.210.03661x5019/1.781.411.95021x7019/2.141.413.77061x9519/2.521.616.09741x12037/2.031.617.612131x15037/2.251.819.614921x18537/2.522.021.818681x24061/2.252.224.424431x30061/2.522.427.730551x40061/2.852.631.138881x50061/3.202.834.648801x630127/2.522.838.66229Electrical PropertiesConductor Operating Temperature : 90°CAmbient Temperature : 30°CCurrent-Carrying Capacities (Amp)Conductor cross- sectional areaReference Method 4 (enclosed in conduit in thermally insulating wall etc)Reference Method 3 (enclosed in conduit on a wall or in trunking etc)Reference Method 1 (clipped direct)Reference Method 11 (on a perforated cable tray, horizontal or vertical)Reference Method 12 (free air)Horizontal flat spacedVertical flat spacedTrefoil2 cables, single- phase a.c. or d.c.3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c. or d.c3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c. or d.c. flat and touching3 or 4 cables, 3-phase a.c. flat and touching or trefoil2 cables, single- phase a.c. or d.c. or flat and touching3 or 4 cables, 3-phase a.c. flat and touching or trefoil2 cables, single- phase a.c. or d.c. or 3 c ables three phase2 cables, single- phase a.c. or d.c. or 3 cables three phase3 cables, trefoil 3-phase a.c.mm2AAAAAAAAAAA1..Voltage Drop (Per Amp Per Meter)Size of conductor2 cables d.c.2 cables, single-phase a.c.3 or 4 cables, 3-phase a.c.Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall)Ref. Methods 1 and 11 (clipped direct or on trays touching)Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall)Ref. Methods 1, 11 and 12 (in trefoil)Ref. Methods 1 and 11 (Flat and touching)1234567mm2mV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/m1...87.96.86.86.86.8104.74.74.7444162.92.92.92.52.52.5rxzrxzrxzrxzrxz251.851.850.311.901.850.1901.851.600.271.651.6000.1651.6001.6000.1901.600351.351.350.291.351.350.1801.351.150.251.151.1500.1551.501.1500.1801.150500.991.000.291.050.990.1801.000.870.250.900.8600.1550.8700.8600.1800.870700.680.700.280.750.680.1750.710.600.240.650.5900.1500.6100.5900.1750.620950.490.510.270.580.490.1700.520.440.230.500.4300.1450.4500.4300.1700.4601200.390.410.260.480.390.1650.430.350.230.420.3400.1400.3700.3400.1650.3801500.320.330.260.430.320.1650.360.290.230.370.2800.1400.3100.2800.1650.3201850.250.270.260.370.260.1650.300.230.230.320.2200.1400.2600.2200.1650.2802400.190.210.260.330.200.1600.250.1850.220.290.1700.1400.2200.1700.1650.2403000.1550.1750.250.310.160.1600.220.1500.220.270.1400.1400.1950.1350.1600.2104000.120.1400.250.290.130.1550.200.1250.220.250.1100.1350.1750.1100.1600.1955000.0930.1200.250.280.1050.1550.1850.1000.220.240.0900.1350.1600.0880.1600.1806300.0720.1000.250.270.0860.1550.1750.0880.210.230.0740.1350.1500.0710.1600.170
Other supplier products
|
|
|
UL Industrial Cables RHH or RHW-2 or USE-2,Website:, 600V, EPR / CSPApplication and DescriptionThese cables are designed for use in lighting and po... |
|
|
|
250V [FA-] MPYS,Website:, MPYCS, MPYCYSStandards:JISC 3410-1999IEC 60332-1IEC 60332-3 Cat.A(for FA-type)CABLE CONSTRUCTIONConductorMTinned annealed... |
|
|
|
S10 IYOI(c) 60 V NEK606 Armoured Tele cableApplications :These cables are flame retardant,Website:, low smoke and halogen free, used for indoor tel... |
|
|
|
Type 209 1.1 to 11KV to AS/NZS 1802ApplicationsType 209 series cable is mainly used as a flexible feeder to machinery,Website:, more suitable as a ... |
|
|
|
250V [FA-] TTY-S,Website:, TTYC-S, TTYCY-S [FA-] TTPY-S, TTPYC-S, TTPYCY-SStandards:JISC 3410-1999IEC 60332-1IEC 60332-3 Cat.A(for FA-type)CABLE CO... |