Type MP-GC Three-Conductor Mine Power Feeder Cable, CPE Jacket, 25kV To ICEA S-75-381

Type MP-GC Three-Conductor Mine Power Feeder Cable,Website:, CPE Sheath, 8kV to ICEA S-75-381ApplicationsThese cables are designed for connections between units of mine distribution systems, suitable forinstalled in duct, conduit or open air and for direct burial in wet and dry locations.StandardsICEA S-75-381/NEMA WC 58ASTM B-8CAN/CSA-C22.2 No.96ConstructionConductorsStranded annealed bare copper conductor.Conductor ShieldConducting layer.InsulationEthylene Propylene Rubber (EPR).Insulation ShieldConducting layer + copper tape.Ground Check ConductorCopper conductor with a yellow polypropylene insulation.Grounding ConductorTinned copper conductor.JacketChlorinated Polyethylene(CPE), black.OptionsOther jacket materials such as CSP/PCP/NBR/PVC are available upon request.Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.Mechanical and Thermal PropertiesMinimum Bending Radius: 12×ODMaximum Operating Temperature: +90℃Dimensions and Weight:ConstructionNo. of StrandsGrounding Conductor SizeGround Check Conductor SizeNominal Insulation ThicknessNominalJacketThicknessNominal Overall DiameterNominal WeightAmpacityNo. of cores×AWG/kcmil-AWG/kcmilAWG/kcmilinchmminchmminchmmlbs/kftkg/kmA3×671080.1152.90.112.81.4135.×47880.1152.90.112.81.5238.×27680.1152.90.112.81.5840.×119580.1152.90.112.81.6642.×1/019480.1152.90.112.81.7444.×2/019380.1152.90.143.61.9048.×3/019280.1152.90.143.62.0050.×4/019180.1152.90.143.62.1253.×250371/080.1152.90.143.62.2256.×350372/080.1152.90.143.62.4361.×500374/080.1152.90.143.62.7068.Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381
Other supplier products
|
|
|
300/500V Mica+XLPE Insulated Individual And Overall Screened fire resistant Instrumentation CablesRE-2X(St)H PiMF...CI. FE 180 PH30 ( CU/MGT+XLPE/I... |
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 9832ApplicationsThese cables have pairs laid up in a foil/braid screen,Website:, s... |
|
|
|
Multipair Individually Screened Cables-Belden Equivalent 9776,Website:, UL2919ApplicationsThese cables have individually screened pairs laid up. Ea... |
|
|
|
UL Industrial Cables THW/THW-2Application and DescriptionThe THW conductor is suitable for most current wiring solutions for residential,Website:, ... |
|
|
|
300/500V fire resistant Braid-Screened Flexible Equipment Cables (Multipair)LI HCH FE180 (PH30) (CU/SR/OS/LSZH 300/500V Class 5)Application:The cab... |