NF M 87-202 EGPF

NF M 87-202 EGSFAPPLICATIONThese NF M 87-202 EGSF instrumentation cables are used for safety extra-low use in petroleum and petrochemical units particularly for the transmission of a.c. or d.c. analogue signals.Standards References:NF M 87-202UTE C 32-014NF C 32-020IEC 60332-1IEC 60332-3-24Conductor:Solid or Stranded copper conductorInsulation:PVC (70 mm maximum pair length)Binder tape:Polyster tapeCollective Screen:Aluminium/polyester tapeOuter Sheath:PVC (Flame retardant,Website:, sunlight, mineral oil and hydrocarton resistant)Outer Sheath Colour:Light-blueCore identification:ColoursNaturalRedBlueYellow1 pairXX1 tripleXXX1 quadXXXXCharacteristicsVoltage Rationg: 300/500VOperating Temperature: -40°C/+90°CInstallation Temperature: MAX+50°CMaximum Voltage: 250VVoltage Test: 2000VMaximum conductor d.c. Resistance:Conductor SizeOhm/km at +20°C1/0.80mm(0.50 sqmm)37.507/0.40mm(0.88 sqmm)21.407/0.53mm(1.50 sqmm)12.50Capacitance between cond. (nf/km):0.5 sqmm ≤ 1450.88 sqmm ≤ 1601.50 sqmm ≤ 180Type/codification:1 SerieNumber of pairs, triples or quads / 01 to 272 SerieLay up in pair(IP) ,triple (IT) , quads (IQ)3 SerieCore section 05 (0.5mm2) , 09 (0.88 mm2) or 15(1.5mm2)4 SerieOverall screen(EG) or individual screen + overall screen(EI)5 SerieMechanical protection: without armour (SF), with armour (FA), with lead + armour(PF)Dimensions and Weight:NF M 87-202Number ofbeamsx cross sectionCond.mm2Outer Diameter(mm)Weight(kg/km)Min.Max.03 IP 05 EGSF3X2X0.50.508.009.309507 IP 05 EGSF7X2X0.50.5010.5012.1016012 IP 05 EGSF12X2X0.50.5013.4015.4025519 IP 05 EGSF19X2X0.50.5016.6019.0038027 IP 05 EGSF27X2X0.50.5019.2022.0051001 IQ 09 EGSF1X4X0.880.887.008.209001 IP 09 EGSF1X2X0.880.886.107.206503 IP 09 EGSF3X2X0.880.8810.5012.0015007 IP 09 EGSF7X2X0.880.8814.0016.0028012 IP 09 EGSF12X2X0.880.8817.9020.4044019 IP 09 EGSF19X2X0.880.8822.0025.3066527 IP 09 EGSF27X2X0.880.8825.8029.6088001 IP 15 EGSF1X2X1.501.506.807.808307 IT 05 EGSF7X3X0.500.5012.0013.8021012 IT 05 EGSF12X3X0.500.5015.5017.1037501 IT 09 EGSF1X3X0.880.886.407.508007 IT 09 EGSF7X3X0.880.8816.4018.1041012 IT 09 EGSF12X3X0.880.8820.8022.9066001 IT 15 EGSF1X3X1.501.507.208.20100
Other supplier products
|
|
|
0.6/1 kV XLPE Insulated,Website:, LSOH (SHF1) Sheathed, Armoured Flame Retardant Power & Control Cables (Multicore)ApplicationThese armoured cables... |
|
|
|
XLPE Insulated 6.35/11KV & 12.7/22KV AS/NZS 1972/1125/3808ApplicationsThese cables are used as HV feeder cables in fixed conditions.StandardsAS/NZS... |
|
|
|
NTMCGCWOEU Flexible Medium-Voltage Single Core Cable VDE 0250 Part 813ApplicationsThese cables are used for connection in switch-gear and for conne... |
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8333ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |
|
|
|
S13 BU(i) 250 V Individual Shielding fire resistant NEK606 Instrument cableApplications :These cables are fire resistant,Website:, flame retardant,... |