150/250V XLPE Insulated, LSOH (SHF1) Sheathed, Armoured Flame Retardant Instrumentation Control Cables (Multicore)
50/250V XLPE Insulated,Website:, LSOH (SHF1) Sheathed, Armoured Flame Retardant Instrumentation & Control Cables (Multicore)ApplicationThese armoured cables are used on board of ships in all locations for fixed installations complying with IEC standards 60092-352. These cables are flame retardant, low smoke& halogen free, suitable for installations on passenger ships, as on other commercial vessels.StandardsIEC 60092-350/351/376/359IEC 60332-1IEC 60332-3-22IEC 60754-1/2IEC 61034ConstructionConductorsClass 2 stranded copper conductor.Inner CoveringLapping.ArmourCopper wire braid.Outer SheathLSOH (SHF1). SHF2 can be offered upon request.Core IdentificationWhite with printed number.Mechanical and Thermal PropertiesBending Radius for Fixed Installations: 6×ODTemperature Range: -30℃ ~ +80℃Dimensions and WeightPart No.ConstructionNo. of cores×Crosssection(mm²)Nominal InsulationThickness mmNominal Sheath Thickness mmNominal OverallDiameter mmNominal Weight kg/kmM092-RE-2XCH-2C0.752×0.750.51.27.280M092-RE-2XCH-3C0.753×0.750.51.27.590M092-RE-2XCH-5C0.755×0.750.51.48.9130M092-RE-2XCH-7C0.757×0.750.51.69.8150M092-RE-2XCH-12C0.7512×0.750.51.712.4230M092-RE-2XCH-19C0.7519×0.750.51.914.6320M092-RE-2XCH-27C0.7527×0.750.52.117.3460M092-RE-2XCH-37C0.7537×0.750.52.219.3590M092-RE-2XCH-2C1.02×1.00.51.47.990M092-RE-2XCH-3C1.03×1.00.51.48.3100M092-RE-2XCH-5C1.05×1.00.51.59.7150M092-RE-2XCH-7C1.07×1.00.51.610.4180M092-RE-2XCH-12C1.012×1.00.51.813.2270M092-RE-2XCH-19C1.019×1.00.52.115.9420M092-RE-2XCH-27C1.027×1.00.52.218.4560M092-RE-2XCH-37C1.037×1.00.52.420.7710
Other supplier products
|
|
600/1000V LSZH Sheathed,Website:, Overall screened & Armoured (single core)Application:This range of screened cables drastically reduce interferenc... |
|
|
50/250V XLPE Insulated,Website:, LSOH (SHF1) Sheathed, Armoured Flame Retardant Instrumentation & Control Cables (Multicore)ApplicationThese armour... |
|
|
250V [FA-] TTY,Website:, TTYC, TTYCY [FA-] TTPY, TTPYC, TTPYCYStandards:JISC 3410-1999IEC 60332-1IEC 60332-3 Cat.A(for FA-type)CABLE CONSTRUCTIONCo... |
|
|
3.6/6kV,Website:, 6/10kV, 8.7/15kV XLPE Insulated, LSOH (SHF1) Sheathed, Armoured Flame Retardant MV Power Cables (Halogen Free Inner Covering)Appl... |
|
|
(N)TSCGEWOEU Medium-Voltage Fixed Installation Cable With Fiber OpticsApplicationsThese cables are used for For laying alongside the conveyor belts... |