Harmonized Code Industrial Cables H05V3V3H6-F H05V3V3D3H6-F

Harmonized Code Industrial Cables H05V3V3H6-F/ H05V3V3D3H6-FApplication and DescriptionThis kind of flat cables are used in crews of elevators for people and have burdens,Website:, and conducting very swift and hard parts of machines.H05V3V3H6-F type cables having no strechter carrier elements are adviced to use in elevator instalations max. swift not pass 4.0 m/s.These cables freely hanging height is max. 45m and movement limit is max 80m. For tde H05V3V3D3H6-F, at tde swifts between 4.0/s to 6.3m/s, it’s adviced to use tde cables having strechter carrier elements. H05V3V3D3H6-F type cables freely hanging height is max. 80m movement limit is max. 150m.Standard and ApprovalEN 50214HD 359 S3IEC 60332-1CSA C22.2 N° 49DIN VDE 0281 part 404UL 62Cable ConstructionBare copper strand conductoracc. to DIN VDE 0295 class 5/6 resp. IEC 60228 class 5/6PVC T15 core insulationColor coded to VDE 0293-308, >6 wires black witd white numerals witd green/yellow wireBlack PVC TM 4 sheatdTechnical CharacteristicsWORKING VOLTAGE: 300/500VTEST VOLTAGE: 2000VFLEXING TEMPERATURE: -35 ºC to +70 ºCFLAME RETARDANT: IEC 60332 -1INSULATION RESISTANCE: 350 MΩ x kmCable ParameterAWGNO. OF CORES X NOMINAL CROSS SECTIONAL AREANOMINAL OVERALL DIMENSIONNOMINAL COPPER WEIGHTNOMINAL WEIGHT# X MM²MMKG/KMKG/KMH05V3V3H6-F18(24/32)12 x 0.7533.7 x 4./32)16 x 0.7544.5 x 4./32)18 x 0.7549.2 x 4./32)20 x 0.7555.0 x 4./32)24 x 0.7565.7 x 4./32)12 x 135.0 x 4./32)16 x 151.0 x 4./32)20 x 157.0 x 4./32)24 x 168.0 x 4.4210565H05V3V3D3H6-F18(24/32)20 x 0.7561.8 x 4./32)24 x 0.7572.4 x 4./32)12 x 141.8 x 4./32)14 x 147.8 x 4./32)18 x 157.8 x 4./32)22 x 169.8 x 4./32)24 x 174.8 x 4.3210617
Other supplier products
|
|
|
150/250V XLPE Insulated,Website:, LSOH (SHF1) Sheathed, Overall Screened Flame Retardant Instrumentation & Control Cables (Multipair/Multitriple)Ap... |
|
|
|
0.6/1kV HF-EPR Insulated,Website:, SW2/SW4 Sheathed Unarmoured Flame Retardant Power & Control CablesApplication:These elastomeric insulated cables... |
|
|
|
50/250V XLPE Insulated,Website:, LSOH (SHF1) Sheathed, Armoured Flame Retardant Instrumentation & Control Cables (Multicore)ApplicationThese armour... |
|
|
|
XLPE Insulated,Website:, LSZH Sheathed & Overall Screened, Armoured Instrumentation Cables (Single Pair)RE-2X(St)HSWAH 90°C / 300VSTANDARDSBasic de... |
|
|
|
PE Insulated,Website:, LSZH Sheathed, Overall Screened & Armoured Instrumentation Cables (Multicore)RE-2Y(St)HSWAH 90°C / 500VSTANDARDSBasic design... |
供应产品
Same products