Harmonized Code Industrial Cables H05VVC4V5-K

Harmonized Code Industrial Cables H05VVC4V5-KApplication and DescriptionThese cables are suitable for dry,Website:, damp and wet locations but not in tde open-air. They are used as screened termination and connection cable in tde control, measuring and signal technology. The copper braiding optimises protection against external interferences, like electromagnetic fields and stray frequencies. Suitable as a signal and impulse cable for control and inspection of industrial plants, machinery and working processes.Standard and ApprovalHD 21.13 S1VDE-0281 Part-13CEI 20-20/13CEI 20-35 (EN60332-1)CEI 20-52UL 2464Cable Construction1 Fine bare copper strandsStrands to VDE-0295 Class-5, IEC 60228 Class-52 PVC insulation T12 to DIN VDE 0281 part 13 Green-yellow grounding (3 conductors and above)Cores to VDE-0293 colors4 PVC inner sheatd TM2 to DIN VDE 0281 part 15 Tinned copper braided shielding, covering approx. 85%6 PVC outer jacket TM5 to DIN VDE 0281 part 1Technical CharacteristicsWORKING VOLTAGE: 300/500vTEST VOLTAGE: 2000voltsFLEXING BENDING RADIUS: 10 x ØSTATIC BENDING RADIUS: 5 x ØFLEXING TEMPERATURE: -5 ºC to +70 ºCSTATIC TEMPERATURE: -40 ºC to +70 ºCFLAME RETARDANT: IEC 60332.1INSULATION RESISTANCE: 20 MΩ x kmCable ParameterAWGNO. OF CORES X NOMINAL CROSS SECTIONAL AREANOMINAL THICKNESS OF INSULATIONNOMINAL THICKNESS OF INNER SHEATHNOMINAL THICKNESS OF OUTER SHEATHNOMINAL OVERALL DIAMETERNOMINAL COPPER WEIGHTNOMINAL WEIGHT# X MM²MMMMMMMMKG/KMKG/KM20(16/32)2 x 0,500.60.70.97,/32)2 x 0,750.60.70./32)2 x 1,00.60.70.98,/30)2 x 1,500.70.71.09,/30)2 x 2,500.80.71.110,/32)3 x 0,500.60.70./32)3 x 0,750.60.70.98,/32)3 x 1,00.60.71.08,/30)3 x 1,500.70.71.09,/30)3 x 2,500.80.71.111,/32)4 x 0,500.60.70.98,/32)4 x 0,750.60.71.09,/32)4 x 1,00.60.71.09,/30)4 x 1,500.70.71.110,/30)4 x 2,500.80.81.212,/32)5 x 0,500.60.71.09,/32)5 x 0,750.60.71.19,/32)5 x 1,00.60.71.110,/30)5 x 1,500.70.81.211,/30)5 x 2,500.80.81.313,/32)7 x 0,500.60.71.110,/32)7 x 0,750.60.71.211,/32)7 x 1,00.60.81.212,/30)7 x 1,500.70.81.314,/30)7 x 2,500.80.81.516,/32)12 x 0,500.60.81.313,/32)12 x 0,750.60.81.313,/32)12 x 1,00.60.81.414,/30)12 x 1,500.70.81.516,/30)12 x 2,500.80.81.719,/32)18 x 0,500.60.91.318,/32)18 x 0,750.60.81.519,/32)18 x 1,00.60.81.520,/30)18 x 1,500.70.81.724,/30)18 x 2,500.80.92.028,/32)25 x 0,500.60.81.622,/32)25 x 0,750.60.91.723,/32)25 x 1,00.60.91.724,/30)25 x 1,500.70.92.028,/30)25 x 2,500.81.02.334,/32)36 x 0.500.60.91.724./32)36 x 0.750.60.91.826./32)36 x 1,00.60.91.927,/50)36 x 1,500.71.02.232,/32)36 x 2,500.81.02.438,/32)48 x 0,500.60.91.928,/32)48 x 0,750.61.02.130,/32)48 x 1,00.61.02.131,/30)48 x 1,500.71.12./30)48 x 2,500.81.22.443,/32)60 x 0,500.61.02.131,/32)60 x 0,750.61.02./32)60 x 1,00.61.02.334,/30)60 x 1,500.71.12.439,/30)60 x 2,500.81.22.447,217062870
Other supplier products
|
|
|
150/250V Mica Tape + XLPE Insulated,Website:, LSOH (SHF1) Sheathed, Overall Screened Fire Resistant Instrumentation & Control Cables (Multipair/Mul... |
|
|
|
2YSLGCGOEU Signal & Control Cable VDE 0250 Part 812ApplicationsThese control,Website:, signalling and bus cables are used for electric and electron... |
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 9836ApplicationsThese cables have pairs laid up in a foil/braid screen,Website:, s... |
|
|
|
Industrial Cables H05V-KApplication and DescriptionThese insulated wires are determined for installation to tde inside of apparatus as well as for ... |
|
|
|
75Ω RG59 Armoured Coaxial Cable NEK606Applications :These 75Ω coaxial cables are suitable for installation on board of ships and other indoor mari... |
供应产品
Same products