Needle Flame Tester
The device use needle flame to simulate small flame effect resulted from equipment incorrect operation so as to evaluate fire hazard.
Expose the specimen to fire in a certain time. The temperature of the copper block is measured by K-type mineral insulated metal sheathed thermocouples (level 1) conforming to IEC 60584-2
The calibration device is capable of automatically measuring the time interval between 100 ° C and 700 ° C and calculating the mean value of the three measurements. The calibration device is also equipped with a digital-analog temperature output that can be used to measure the external time interval.
Expose the specimen to fire in a certain time. The temperature of the copper block is measured by K-type mineral insulated metal sheathed thermocouples (level 1) conforming to IEC 60584-2
The calibration device is capable of automatically measuring the time interval between 100 ° C and 700 ° C and calculating the mean value of the three measurements. The calibration device is also equipped with a digital-analog temperature output that can be used to measure the external time interval.
Introduction
Technical Parameters
| Items | Parameters |
| Specimen | Synthetic materials |
| Test standards | DIN EN 60695-11-5 |
| Sensor | Temperature |
| Power supply | 230 VAC / 15 VA |
| Dimension | 500 x 400 x 300 mm (W x D x H) |
| Weight | 15g |
在线联系供应商
Other supplier products
| fabric textile random tumble pilling tester | Random Tumble Pilling Tester, to determine the pilling and fuzzing characteristics of textile fabrics.Random Tumble Pilling Tester uses stainless s... | |
| ISO 5470 taber type abrasion and wear test instrument | Taber Abrasion Tester, which often referred to as “Taber Abraser” or “Taber Abrasion Machine”, is a testing machine to test... | |
| Fabric softness tester | Softness Tester, to determine the softness of leather and coated fabrics and other soft materials. Softness tester does not need samples to be cut ... | |
| Medical Face Mask Synthetic Blood Penetration Resistance Test equipment | Medical masks synthetic blood penetration tester is used to determine the resistance of medical protective masks to penetration by synthetic blood ... | |
| Needle Flame Tester | The device use needle flame to simulate small flame effect resulted from equipment incorrect operation so as to evaluate fire hazard.Expose the spe... |
Same products
| Blanket Flammability Test Machine | 卖方: Standard Groups | Bed Blanket Flammability Tester-It is mainly used for testing the flame retardant performance of ... | |
| High Temperature Oxygen Index Tester | 卖方: Standard Groups | The High-Temperature Oxygen Index (TOI) measuring instrument determines oxygen index at up to 125... | |
| Limiting Oxygen Index Tester | 卖方: Standard Groups | The Limiting Oxygen Index Tester measures the minimum oxygen concentration needed to sustain comb... | |
| Vertical Flammability Tester | 卖方: Standard Groups | Vertical Flammability Chamber for measuring the vertical flame spread for children’ sleepwe... | |
| 45 Degree Flammability Tester | 卖方: Standard Groups | Application 45 Degree Flammability Tester is used to determine the burning characteristics of te... |















