Solar Radiation Meters
Product Introduction:
The purpose of this instrument is to measure the temperature change of the sample with radiant heat.
Arrange the sample and its reference material on the sample table, install it on the measuring table at an Angle of 45°, set a heating plate parallel to the measuring table, measure the surface temperature of the two samples with a radiation thermometer, etc., and measure by regression extrapolation method.
Standard:
ISO 9060:2018
ISO 9060
ISO 17025
Scope of Application:
The purpose of this instrument is to measure the temperature change of the sample with radiant heat. This defines the core function: to quantify how a material's temperature changes when subjected to radiation from a heat source. Arrange the sample and its reference material on the sample table, install it on the measuring table at an Angle of 45°, set a heating plate parallel to the measuring table, measure the surface temperature of the two samples with a radiation thermometer, etc., and measure by regression extrapolation method. The test involves placing the material sample alongside a reference material (which has known thermal properties) on a holder set at a 45° angle. A heated plate, acting as the radiant heat source, is positioned parallel to this angled table at a fixed distance. A radiation thermometer (a non-contact device) is used to measure the surface temperature of both the sample and the reference over time as they are exposed to the radiant heat. The "regression extrapolation method" suggests a method of analyzing the temperature vs. time data to derive specific material properties related to thermal response. The instrument is used in laboratories for material science, protective equipment testing, and thermal performance evaluation.
Product Advantages:
Measures Material Response to Radiant Heat: Quantifies the temperature change of a sample when exposed to controlled radiant heat, providing data on its thermal behavior.
Controlled Radiant Heat Source: Utilizes a heated plate with controlled operating temperature and PID control for stable heat output.
Fixed Geometry: The specific 45° angle and fixed spacing ensure consistent and repeatable radiant heat exposure.
Allows Comparison to Reference: Testing a sample alongside a reference material enables comparative analysis of thermal performance.
Non-Contact Temperature Measurement: Uses a radiation thermometer, avoiding interference with the sample surface during measurement.
Provides Quantitative Data: Generates numerical temperature vs. time data for analysis.
Operates Under Controlled Environment: Designed for use in a measuring chamber with specified temperature and humidity conditions.
Product Features:
Sample table or holder designed to accommodate both a test sample and a reference material of a specific size (10 cm x 7 cm).
Mounting system for the sample table positioned at a 45° angle relative to the radiant heat source. The table is likely painted black (as indicated by "black painting" for the measuring table Angle) to standardize its thermal properties.
Parallel heating plate made of aluminum black plate, serving as the controlled radiant heat source.
Heater with a controlled operating temperature (90℃) managed by PID control for stability.
Fixed spacing between the sample station (measuring table) and the heater (15cm).
Requires an external radiation thermometer or thermal imaging system (as noted in the "Attention" section) to measure the surface temperature of the samples non-contact.
Designed to operate within a controlled measuring chamber environment with specified temperature (20$pm$1℃) and relative humidity (50$pm$10%RH).
Includes calibrated components for the measuring table and heater.
Uses a regression extrapolation method for data analysis.
Includes a heater storage box.
Specification parameters:
Model: STD-IT-PT
Sample size: 10 X 7cm
Compare sample size: 10 X 7cm
Heater: Aluminum black plate
Heater operating temperature: 90℃
Heater control mode: PID control mode
Measuring table Angle: 45 degrees (black painting)
Sample station/heater spacing: 15cm
Equipment calibration: Measuring table (including sample mounting rack and sample table)
Heater (including temperature controller)
Heater storage box
Measuring chamber conditions: 20±1℃, 50± 10%RH
Power supply: AC100V or 220v (using downlink transformer), 50hz or 60hz, single phase
Attention: Thermal imaging {detection wavelength range 8 —— 13μm/ detector Hg, Cd, Te system}, controller {temperature resolution 0.05℃, emissivity 1.0. scanning frame time 0.6 —— 0.8 seconds, image processing (setting of start time, display of average temperature inside the box)}, monitor {high resolution monitor or LCD color display with built-in controller}, please prepare yourself.
在线联系供应商
Other supplier products
| Anti-drill tester (Friction method)-QINSUN | Product Overview TheAnti-drill Tester (Friction Method)is a specialized instrument designed to evaluate the drill resistance of materials such as ... | |
| Civil Aviation Aircraft Interior Non-metallic Materials Flame Retardant Property Tester | Compliance Standards FAR25.853 (FAA Airworthiness Standards for Transport Category Aircraft) CCAR-25-R4.853 (Chinese Civil Aviation Regulations A... | |
| tank cleaning machine pipe fittings | As one of the most professional tank cleaning systems manufacturers in China, we warmly welcome you to wholesale customized tank cleaning systems a... | |
| Needle Flame Tester | Standard GB/T 5169.5: Electrical & Electronic Equipment – Needle Flame Test Method IEC 60695-11-5/IEC 60695-2-2: Fire Hazard Testing &n... | |
| Tipping Frames | STD-5D Adjustable for different drum sizes Compatible with TONSON valves for flow control Pneumatic dumping (saves time and labor) Drum mouth h... |
Same products
| Blanket Flammability Test Machine | 卖方: Standard Groups | Bed Blanket Flammability Tester-It is mainly used for testing the flame retardant performance of ... | |
| High Temperature Oxygen Index Tester | 卖方: Standard Groups | The High-Temperature Oxygen Index (TOI) measuring instrument determines oxygen index at up to 125... | |
| Limiting Oxygen Index Tester | 卖方: Standard Groups | The Limiting Oxygen Index Tester measures the minimum oxygen concentration needed to sustain comb... | |
| Vertical Flammability Tester | 卖方: Standard Groups | Vertical Flammability Chamber for measuring the vertical flame spread for children’ sleepwe... | |
| 45 Degree Flammability Tester | 卖方: Standard Groups | Application 45 Degree Flammability Tester is used to determine the burning characteristics of te... |