Cone Calorimeter / Cone calorimetric test equipment,Automated Cone Calorimeter
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Application
The Cone Calorimeter is widely used to evaluate fire performance of materials and products under controlled heat-flux exposure. It provides accurate characterization of heat release, smoke generation, ignition properties, toxic gas production, and combustion behavior.
Common applications include building materials, foams, plastics, composites, textiles, cable insulation, transportation materials (railway, maritime, automotive interiors), aerospace composites, polymer research, and fire-retardant development.
Its measurement data is essential for predicting fire hazards, conducting flame-retardant assessments, verifying regulatory compliance, and supporting fire-safety engineering analysis.
Standards
The system complies with major international fire-reaction standards, including:
ASTM E1354 – Heat and Visible Smoke Release Rates
ISO 5660-1 – Heat release, smoke production, and mass loss rate
ASTM E1474 – Flame spread evaluation
ASTM F1550 – Flame spread of plastics in furniture
ASTM E1740 – Large-panel cone calorimeter testing
ASTM D6113 – Fire performance of materials
IMO MSC 40(64) – Marine fire test procedures
BS 476-15 – Fire tests for building materials
NFPA 264 / NFPA 271 – Fire and smoke measurement standards
ULC-S135-04 – Canadian fire test standard
CSN EN 45545-2+A1 – Railway vehicle fire protection
CSN EN 13501-1+A1 – Classification of building products
Features
Ignition System
10 kV spark igniter with fire-off safety system; position automatically detected via mechanical linkage.
Fully automated ignition, timing, gas control, and flame-off functions.
Exhaust System
Stainless-steel design including hood, pipes, diffusion plate, orifice flow meter, and axial-flow fan.
Long-life stainless-steel smoke collection cover, sampling needle, and exhaust fan.
Gas Sampling System
Ring sampler with 12 evenly distributed pores opposite airflow direction.
Three-stage 0.5 μm precision filtration with particle filter, CO₂ filter, and water trap.
Refrigerated cold trap with 0–5 °C temperature control.
Dust filter installed 685 mm from smoke-collecting hood.
Measuring System
Paramagnetic O₂ analyzer (0–25%), Servomex sensor with linear response.
Laser system for smoke-density measurement.
High-precision load cell for dynamic mass-loss monitoring.
PID temperature control with three thermocouples for cone-heater measurement.
User Operating System
LabVIEW-based professional control platform; intuitive and user-friendly.
PID temperature controller integrated with programmable control module.
PLC-based acquisition and airflow regulation; automatic sample ID management and database recordkeeping.
Technical Parameters
| Item | Parameter | Value |
|---|---|---|
| Power supply | – | 208–230 V, 50/60 Hz, 50 A, single phase |
| Cone heater | – | 5000 W Inconel heater, 0–120 kW/m² |
| Sample size | – | 100 mm × 100 mm × ≤50 mm |
| Ignition | – | 10 kV automatic spark igniter |
| Temperature control | – | PID, 3× K-type thermocouples |
| Exhaust system | – | Stainless-steel hood, duct, orifice meter, axial fan |
| Gas sampling | – | 12-pore ring sampler, 0.5 µm triple filtration, 0–5 °C cold trap |
| Gas analyzers | – | O₂ paramagnetic (0–25%); CO₂ NDIR (0–10%); CO NDIR (0–1%) |
| Smoke measurement | – | He-Ne laser photometric system |
| Load measurement | – | Sartorius load cell, 0.01 g resolution |
| Data acquisition | – | 16-bit A/D, 4 scans/sec |
| Control system | – | LabVIEW + PLC, touchscreen control |
| Data output | – | Excel reports, customizable formats |
| System configuration | – | 19" rack modules; customizable full-system layout |
Accessories
• 10 kV electronic igniter
• Stainless-steel exhaust hood and ducting
• Orifice plate flow-measurement module
• Laser smoke-density measurement system
• Paramagnetic oxygen analyzer
• CO and CO₂ NDIR analyzers
• Load-cell weighing module
• Cold trap (0–5 °C)
• Gas-sampling ring with 12 sampling ports
• LabVIEW control software and PLC system
• Sample holder and retainer frame
• Data-acquisition platform and reporting package
Test Procedures
Place the specimen in the sample holder and input test parameters via the touchscreen control system.
The system automatically performs ignition, heat-flux adjustment, and timing.
Real-time measurement of HRR, oxygen consumption, smoke density, mass loss, CO/CO₂ concentration, and temperature.
Data acquisition system stores all curves and numerical results in the integrated database.
Export test report through automated Excel reporting functions.
After testing, allow system purge and remove combusted residue.
Maintenance Information
Regularly inspect ignition electrode, spark generator, and flame-off mechanism.
Clean the exhaust hood and ducting to prevent soot buildup.
Calibrate oxygen, CO, and CO₂ analyzers periodically for accuracy.
Check load cell, thermocouples, and flow-measurement system for stability.
Inspect cold trap and refrigeration unit to ensure correct 0–5 °C operation.
Replace filters in the gas-sampling train as required.
Back up database files and update the LabVIEW system regularly.
Ensure all stainless-steel components remain clean and corrosion-free for long service life.
在线联系供应商
Other supplier products
| Cell thickness gauge | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Cell Thickness Gauge is a precision measuring instrument designed for accurate thicknes... | |
| Aatcc 112 Textile Formaldehyde Content Tester | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Textile Formaldehyde Content Tester is a precision instrument designed to... | |
| Walk-in Environmental Constant Temperature and Humidity Test Chamber | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB/T2423.3 Environmental Testing of Electronic and Electrical Products Ca: High ... | |
| Bone Screw Pull-out Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard YY/T 1504. ASTM F543: standard specifies a test method for measuring the axial f... | |
| High-efficiency filter scanning test bench | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system supports and complies with the following standards: (1) GB/T 14295-2... |
Same products
| HDPE高速水冷双壁波纹管生产线 | 卖方: Shandong HUASU Plastic Technology Co.,Ltd. | 机头模具采用双流道结构、氮化磨光处理机头,偏壁调整方便快捷,保证内外层壁厚均匀和稳定成型。 最新设计密闭压力水冷冷却结构,冷却充分,多点分布真空系统,效率更高,生产速度更快。 双层在线扩口功... | |
| PanEVAP & MVR system | 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | A multiple-effect evaporator is a device that efficiently uses steam heat to evaporate water. Wat... | |
| PanGAP wide gap welded plate heat exchanger | 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanGAP wide gap welded plate heat exchangerconsists of a welded plate pack with different channel... | |
| PanBloc welded plate heat exchanger | 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanBloc welded plate heat exchangeris compact and efficient, although fully welded, is totally ac... | |
| PanBox welded plate heat exchanger | 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanBox welded plate heat exchangerconsists of a laser welded plate pack with optimized corrugated... |