Cabin Air Filter Test System(Particle removal & Gas adsorption),Automotive Cabin Air Filter Efficiency Analyzer
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Test System for both particle separation and gas absorption/desorption of of air filters for passenger compartments (DIN 71460-1/2. ISO 11155-1/2). It povides a maximum of paramater testing for cabin air filters.
Applications
Fractional efficiency according to ISO 11155-1 (DIN 71460-1)
Gas adsorption tests according to ISO 11155-2 (DIN 71460-2)
Adsorption/desorption tests
Research and development tasks on automotive cabin air filters
Standards
GB/T 32085.1 — Automotive Air Conditioning Filters, Part 1: Dust Filtration Test
GB/T 32085.2 — Automotive Air Conditioning Filters, Part 2: Gas Filtration Test
DIN 71460-1 — Road Vehicles, Cabin Air Filters, Part 1: Particulate Filter Test
DIN 71460-2 — Road Vehicles, Cabin Air Filters, Part 2: Gas Filter Test
ISO/TS 11155-1 — Road Vehicles, In-Cabin Air Filters, Part 1: Dust Filtration Test
ISO 11155-2 — Road Vehicles, In-Cabin Air Filters, Part 2
ISO 10121-1 / ISO 10121-2 — General Methods for Air Filter Performance Testing
Features
standard compliant testing of filter media and filter elements
combined testing with particles and with gases
very flexible system configuration possible
Technical Data
| Parameter | Unit | Value |
|---|---|---|
| Test flow rate | m³/h | 70 … 700 |
| Test aerosol | – | DEHS, DOP, PAO, KCl, NaCl, etc. |
| Test gases | – | n-Butane 80 ppm, Toluene 80 ppm, Sulfur dioxide 30 ppm, Hydrogen sulfide 10 ppm |
| Measuring range, differential pressure | Pa | 0 … 1000 (± 2 %) |
| Test specimen dimensions | mm | max. 600 × 300 |
| Operating medium (gas/air) | – | Room air at standard test conditions (23°C ± 2 K; 50 % ± 2 % RH) |
| Power supply | – | 400 VAC / 3P / 75 A / 50 … 60 Hz and 3 × 230 VAC / 2P / 16 A / 60 Hz |
| Aerosol generation technology | – | Dust disperser SAG 410/L, Atomizer ATM 220. etc. |
| Aerosol conditioning technology | – | Electrostatic Aerosol Neutralizer EAN 581 |
| Aerosol measurement instruments | – | Aerosol spectrometer LAP 322 |
| Gas analysers | – | FID, NDIR |
| Sensors (others) | – | Temperature, relative humidity, absolute pressure |
| System dimensions (W × H × D) | mm | 3700 × 3000 × 3700 |
Principle of Operation
Defined airflow passes through the HEPA inlet filter and the test duct.
The test filter is installed in the adapter, ensuring easy insertion and observation.
Particle aerosols and specific gases are injected upstream of the filter.
Downstream, laser aerosol analyzers and gas analyzers measure particle concentrations and gas composition.
The system calculates fractional efficiency, dust loading, and adsorption/desorption curves.
The exhaust system ensures stable gas conditions and safe operation during filter replacement.
Software allows automated, repeatable testing and data recording/analysis.
Operating Instructions
Install the test filter using the dedicated adapter to ensure airtight sealing.
Set aerosol and gas flow rates and concentrations according to standards.
Turn on the exhaust system to maintain stable gas dosage and safe operation.
Calibrate sensors and gas analyzers before first use.
Use software-guided automated test procedures, or manual mode for research and calibration.
Maintain stable temperature and humidity to ensure accurate gas adsorption measurements.
Testing Procedure
Mount the filter in the adapter and confirm airtight sealing.
Set particle and gas flow rates/concentrations; start the exhaust system.
Start the automated test via software control.
Measure differential pressure, dust accumulation, and fractional efficiency.
Gas analyzers record downstream concentrations to generate adsorption/desorption curves.
After the test, move the filter to a safe area; the software generates a test report.
Export data for long-term analysis, statistics, and compliance verification.
在线联系供应商
Other supplier products
| Glove Thermal Insulation Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The tester complies with and supports testing according to: BS 6526:2002 &ndash... | |
| Plastic Friction and Wear Testing Machine ASTM D1894 | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Application Evaluate friction and wear properties of plastic materials under... | |
| Vehicle level high low temperature humidity test chamber manufacturer | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com TheVehicle-Level High/Low Temperature and Humidity Test Chamberis a large-sca... | |
| Laser Compression Deformation Tester,Laser deformation measurement system | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Laser Compression Deformation Tester for sealing strips is designed for automotive seal... | |
| End-face rotary friction and wear testing machine measurement equipment | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The thrust washer friction testing machine is mainly used to simulate the fri... |
Same products
| HDPE高速水冷双壁波纹管生产线 | 卖方: Shandong HUASU Plastic Technology Co.,Ltd. | 机头模具采用双流道结构、氮化磨光处理机头,偏壁调整方便快捷,保证内外层壁厚均匀和稳定成型。 最新设计密闭压力水冷冷却结构,冷却充分,多点分布真空系统,效率更高,生产速度更快。 双层在线扩口功... | |
| PanEVAP & MVR system | 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | A multiple-effect evaporator is a device that efficiently uses steam heat to evaporate water. Wat... | |
| PanGAP wide gap welded plate heat exchanger | 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanGAP wide gap welded plate heat exchangerconsists of a welded plate pack with different channel... | |
| PanBloc welded plate heat exchanger | 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanBloc welded plate heat exchangeris compact and efficient, although fully welded, is totally ac... | |
| PanBox welded plate heat exchanger | 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanBox welded plate heat exchangerconsists of a laser welded plate pack with optimized corrugated... |