Thermal Conductivity Tester for Silicone and Ceramic Substrates,ASTM D5470 industrial and lab material thermal tester

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Thermal Conductivity Tester for Silicone and Ceramic Substrates is a high-precision instrument designed to measure thermal resistance, thermal conductivity, and interface contact thermal resistance of thin heat conductors, solid electrical insulation materials, thermal grease, resins, rubber, beryllium oxide ceramics, and aluminum oxide ceramics. The instrument can test solid sheet materials directly, and with the use of a sample frame, it can measure powdered and paste materials.

Designed and manufactured in full compliance with ASTM D5470-2017 standards, tester incorporates over a decade of production experience and user feedback to provide mature and reliable performance. The instrument features servo-controlled precise automatic pressing, automatic thickness measurement, 6-point temperature gradient detection, and computer-controlled fully automatic operation. Built-in thermal protection around the test rod reduces environmental influence, enabling precise measurement of materials under varying pressures. This tester also includes automatic cold-end temperature compensation, eliminating the need for ice-water compensation.

Users can select standard or compact models according to laboratory space constraints without compromising performance. The instrument is widely applied in universities, research institutes, quality inspection laboratories, and industrial production plants.

Application

This tester is suitable for testing:

Thin heat conductors and metals

Solid electrical insulation materials

Thermal greases and thermal silicone pads

Resins, rubber, and engineering plastics

Beryllium oxide ceramics and aluminum oxide ceramics

Aluminum substrates, copper-clad laminates, and composite ceramics

Foam copper, graphite sheets, and other novel thermal interface materials

Typical applications include:

Academic research: Thermal property analysis of materials

Industrial quality control: Verifying thermal performance of production materials

R&D labs: Testing thermal interface materials (TIMs) and adhesives

Production sites: Evaluating aging, reliability, and compression performance of materials

Standards

The instrument complies with:

MIL-I-49456A – Insulating Sheet Materials, Thermally Conductive Resins, Glass-Fiber Reinforced Thermal Materials

GB 5598-2015 – Method for Determining Thermal Conductivity of Beryllium Oxide Ceramics

ASTM D5470-2017 – Test Method for Thermal Transmission Properties of Thin Thermally Conductive Solid Electrical Insulation Materials

GB/T 29313-2012 – Test Methods for Thermal Conductivity of Electrical Insulation Materials

Parameters

ItemSpecification
Sample size Φ30 mm or 20×20 mm (standard); custom sizes available
Sample thickness 0.001–50 mm; typical 0.02–20 mm
Hot plate temperature range Room temperature–100 °C (standard); optional 300 °C or 500 °C
Cold plate temperature range 0–99 °C; precision 0.01 °C (with high-precision low-temperature water bath)
Thermal conductivity range 0.01–50 W/m·K; 0.1–300 W/m·K, software auto-switching
Thermal resistance range 0.05–0.000005 m²·K/W
Pressure range 0–1000 N; servo-controlled; precision 1 N
Thickness measurement range 0–50 mm; resolution 0.1 μm; automatic
Sample quantity 1 piece (thin film, multiple layers)
Measurement accuracy Better than 3%
Test modes Thermal resistance under varying pressures; material thermal conductivity; contact thermal resistance; aging reliability; compression performance; inter-sample contact thermal resistance
Automation Computer-controlled fully automatic measurement and report output
Power supply 220 V / 50 Hz; 500 W

Features

Measures thermal conductivity, thermal resistance, and interface contact thermal resistance of silicone, ceramic, and insulating materials

Servo-controlled automatic pressing and thickness measurement

6-point temperature gradient detection for high-precision results

Built-in thermal protection reduces environmental influence

Automatic cold-end temperature compensation eliminates ice-water requirements

Can measure both solid sheets and powder/paste materials

Fully computer-controlled with data recording, printing, and reporting

Available in standard and compact models to save laboratory space

Accessories

Main instrument

Analysis software (Chinese & English versions)

Precision low-temperature constant temperature water bath (high-precision, large-capacity)

Calibration reference samples (2 pieces)

Sample accessories set (thermal grease, paste, powder test boxes, stamping molds for sheet samples)

Test Procedures

Prepare the sample according to size and thickness specifications. Powder/paste materials require a sample frame.

Place the sample between the hot and cold plates.

Set desired hot and cold plate temperatures via software.

Apply pressure using the servo-controlled mechanism.

Start the measurement; the system automatically records temperature gradients and thickness.

Wait for completion; software calculates thermal conductivity, thermal resistance, and interface contact thermal resistance.

Save and print results as required.

Maintenance Information

Keep hot and cold plates clean and free from residue.

Regularly calibrate using reference samples.

Inspect thermal protection devices and pressure mechanisms for proper operation.

Maintain stable laboratory conditions to ensure consistent measurements.

Ensure proper operation of water bath for cold plate stability.


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Versatile Environmental Test Chamber
Versatile Environmental Test Chamber Features and Benefits 1.Ultra-high precision temperature and humidity control, equipped with high precision temperature and humidity sensors and c...
Cork Puncture and Chip Detection Instrument
Cork Puncture and Chip Detection Instrument Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The main purpose of the rubber stopper puncture debris detector is to evaluat...
Metal Corrosivity Tester
Metal Corrosivity Tester The Metal Corrosivity Tester is used to determine the corrosivity of liquids and solids that may become liquid during transport. It conforms to the...
Rubber non-rotor vulcanization Tester
Rubber non-rotor vulcanization Tester The Rubber Non-Rotor Vulcanization Tester is a precision instrument designed for the rubber processing industry to monitor and control rubber mater...
Goggle Puncture Resistance Evaluation Apparatus
Goggle Puncture Resistance Evaluation Apparatus Applicable standards: GB 811-2010 ECE R22.05 EN1077 Purpose It is to make a certain weight of sharp objects fall from the height specified in ...
供应产品

Same products

SUGA SX75 super xenon weather meter supplier
SUGA SX75 super xenon weather meter supplier 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications SUGA SX75 7.5kW Super Xenon...
UV & Carbon Arc Light Exposure Tester
UV & Carbon Arc Light Exposure Tester 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The Carbon Arc Aging Chambe...
Acid corrosion resistance cabinet for toilets
Acid corrosion resistance cabinet for toilets 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Toilet seat hydrochloric ac...
Automated Filter Porosity Testing System
Automated Filter Porosity Testing System 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Application (1) Determining pore size di...
Spray Aerosol Ignition Distance Tester
Spray Aerosol Ignition Distance Tester 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Spray Aerosol Ignition Dist...