Double Plate Thermal Conductivity Apparatus
Application
Building Engineering: Used to evaluate and optimize the thermal performance of building materials to improve the insulation and heat-resistant properties of buildings.
Industrial Engineering: Used to monitor and control the thermal conductivity performance of industrial equipment to improve production efficiency and reduce energy consumption.
Environmental Monitoring: Used to monitor and evaluate the environmental impact of building materials, such as thermal pollution and thermal environment.
Scientific Research: Used to research and develop new materials to improve their thermal conductivity and application value.
The design and operation procedures of these devices ensure the accuracy and reliability of measurements, providing important technical support for the fields of materials science and engineering.
Standards
GB/T 10294-2008:Determination of Steady State Thermal Resistance and Related Properties of Thermal Insulation Materials
GB/T 3399-1982:Test method for thermal conductivity of plastics - Heat - resistant plate method
GB/T 10801.1-2002:Thermal insulation polystyrene foam
GB/T 10801.2-2002:Extruded polystyrene foam
GB/T 3139-2005:Test method for thermal conductivity of fiber reinforced plastics
GB/T 17794-2008:Flexible foam rubber and plastic insulation products
ASTM C518:Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus
IS0 8301:Thermal Insulation — Determination of Steady-State Thermal Resistance and Related Properties — Heat Flow Meter Apparatus
DIN EN 12667:Thermal Performance of Building Materials and Products - Determination of Thermal Resistance by Means of Guarded Hot Plate and Heat Flow Meter Methods - Products of High and Medium Thermal Resistance
Features
Chassis is nice. Test box shell uses spray method. It has strong mechanical strength, anti-corrosion
The device is small and the unique casters are designed to increase the flexibility of the thermometer movement.
High safety performance. It not only adopts the use of circuit and refrigeration cycle independent design, but also can ensure that the electrical part of the collected data from the impact of water, and improve stability.
Good performance of temperature stability and unique protection board design, can form a one-dimensional protection, so that it has no loss of temperature.
Online double standard company unique technology which can calibrate the temperature, calibration system error, is accurate, fast and convenient.
Technical Parameters
| Items | Parameters |
| Specimen standard size | 300mm × 300mm × H (5 ~ 40) mm |
| Specimen flatness | 0.1mm |
| Thermal conductivity measurement display range | (0.001 ~ 2.000) W / (m • K) |
| Thermal conductivity measurement accuracy | ± 3% |
| Thermal conductivity measurement Repeatability | ± 1% |
| Temperature resolution | 0.01 ℃ |
| Temperature control accuracy | 0.05 ℃ |
| Different types of thermal conductivity tester temperature measurement range | Model | Cold plate temperature control interface ℃ | Hot plate temperature control range ℃ |
| IMDRY3001-I | Room temperature - 95 ℃ | Room temperature - 100 ℃ | |
| IMDRY3001-Ⅱ | -℃ -5 ℃ - 95 ℃ | 15 ℃ - 95 ℃ | |
| IMDRY3001-Ⅲ | -10 ℃ - 95 ℃ | 10 ℃ - 95 ℃ | |
| IMDRY3001-IV | -15 ℃ - 95 ℃ | 5 ℃ - 95 ℃ | |
| IMDRY3001-V | -20 ° C - 95 ° C | 0 ° C - 95 ° C | |
| IMDRY3001-Ⅵ | -30 ℃ -95 ℃ | -10 ℃ -95 ℃ | |
| IMDRY3001-VII | -40 ℃- 95 ℃ | -20 ℃ - 95 ℃ | |
| Power supply | AC 220V ± 10%, 2.5KW | ||
| Specimen thickness | Standard 25mm, range (5 ~ 40) mm | ||
| Specimen thermal resistance requirements | the thermal resistance of the specimen should not be less than 0.1 (m2 • K) / W, and should meet the thickness of the standard thickness Requirements; if the lower limit of thermal resistance of the specimen is as low as 0.02 (m2 • K) / W, the accuracy does not necessarily meet the requirements. | ||
| Clamping force | No more than 2.5kPa | ||
在线联系供应商
Other supplier products
| Cylindrical Battery In-Situ Volume Swelling Testing System | The Cylindrical Battery In-Situ Volume Swelling Testing System is designed for real-time measurement and analysis of volume and dimensional changes... | |
| Demesia Zigzag Tester | The Demesia Zigzag Tester is a professional device used to test the flexural resistance of materials such as rubber, leather, synthetic leather, an... | |
| Whole shoe breathability and heat preservation testing machine | Standard SATRA TM376: Thermal insulation testing of footwear with sock integration. SATRA TM386: Water vapor permeability assessment for athlet... | |
| Femoral Condyles Components Fatigue Performance Tester | Standard ASTM WK51649: Specifies fatigue testing protocols for metallic femoral components in total knee arthroplasty, including F-N curve generat... | |
| Cleanliness automatic extractor | Component Cleanliness Cabinet equipped with cleaning modes such as pressure jet cleaning, perfusion cleaning, spray cleaning, etc., the cleaning ag... |
Same products
| Racing Seatback Headrest Restraint Device, Front and Rear Impact Testing Machine | 卖方: Standard International Group (HK) Limited | The Racing Seat Headrest Restraint and Front-Rear Impact Testing Machine is designed to evaluate ... | |
| Laboratory car wash simulator for automotive testing | 卖方: Standard International Group (HK) Limited | The Laboratory Car Wash Simulator is a specialized testing system designed to replicate automatic... | |
| Steam jet durability testing machine | 卖方: Standard International Group (HK) Limited | The Steam Jet Test Chamber is designed to evaluate the durability and performance of materials an... | |
| Seat Bumping and Creep Test Bench | 卖方: Standard International Group (HK) Limited | Application Applications of the Single Station Jounce Tester include, but are not limited to, th... | |
| high precision impact testing machine | 卖方: Standard International Group (HK) Limited | The Impact Testing Machine is a precision instrument designed for material testing in the aerospa... |