Manikin Breathing System
Application
HVAC education and research, including indoor air quality evaluation, human breathing exposure assessment in confined spaces, and cross-infection risk analysis of airborne diseases;
Medical and public health research, including studies on respiratory exposure, pollutant dispersion, and effectiveness of protective measures;
Occupational health assessment, such as evaluation of dust, PM2.5. and gaseous pollutant exposure in workshops and factories;
Breathing exposure assessment in aerospace cabins and confined environments, including civil and military aircraft, helicopters, space stations, re-entry capsules, submarines, and deep-sea systems;
Breathing exposure assessment inside vehicles and transportation systems, including buses, passenger cars, new energy vehicles, high-speed trains, subways, ships, and submarines;
Evaluation of breathing exposure and comfort of wearable masks, including space suits, pilot oxygen masks, aircraft passenger oxygen masks, and chemical protective mask systems.
Standards
GB/T 14296-2005 — Indoor Air Quality Evaluation Methods (Air Pollutant Exposure)
GB/T 18883-2022 — Indoor Air Quality Standard
ISO 7730:2005 — Ergonomics of the Thermal Environment — Analytical Determination and Interpretation of Thermal Comfort
ASTM F1291-2020 — Test Methods Related to Breathing and Exposure Measurement
Product Specifications
| Component | Technical Parameters |
|---|---|
| Breathing Function | Sinusoidal breathing profile; breathing frequency 10 breaths/min (one cycle 6.0 s: exhalation 2.0 s, inhalation 2.0 s, pause 2.0 s); customizable on request |
| Exhalation Volume | Adjustable: 7 L/min, 15 L/min, 23 L/min; exhalation positive pressure 10–80 kPa (0.1–0.8 bar); inhalation negative pressure approx. −0.4 bar |
| Breathing Mode | Switchable nasal breathing or oral breathing (when used with a thermal manikin) |
| Exhaled Airflow | Equipped with heating module; airflow temperature adjustable from 34 to 36 °C |
| Sampling Branch | Main breathing line includes a sampling port for aerosol or pollutant sampling |
| Electrical Control System | Integrated control cabinet with pressure gauges and flow display; power supply AC 220 V / 50 Hz; total power ≤ 350 W; exhaled air heating module power ≤ 1000 W |
| Operating Environment | Temperature 10–40 °C; humidity 15–95% |
| Others | Can be used with a thermal manikin or independently with a manikin head; platform with lockable caster wheels; over-pressure and short-circuit protection; total weight approx. 45 kg |
Features
Accurate simulation of human breathing cycles and airflow parameters, with support for customized breathing functions;
Adjustable exhalation temperature to ensure experimental conditions are close to real human breathing;
Compatible with a 16-zone thermal manikin to simulate interaction between body heat sources and breathing airflow;
Modular design allowing independent use or localized experiments on specific body parts;
High-sensitivity airflow control components with millisecond-level response, using imported components from Germany;
Comprehensive safety protection, including over-pressure protection, short-circuit protection, and lockable caster wheels.
在线联系供应商
Other supplier products
| Standard Helmet Visual Field Tester | Standards EN 1078:2023: Helmets for Pedal Cyclists, Skateboarders, and Roller Skaters CE Certification(Conformité Européenne) Equi... | |
| Battery Slurry Resistance Tester | The Battery Slurry Resistance Tester is a precision testing system designed to measure the resistivity of high-solid battery slurries and conductiv... | |
| Precision Fiber Slicer | G214Precision Fiber Slicer is used to make the accurate fiber cross-sectional specimens for further inspection or research under the microscope. In... | |
| Intramedullary Nails Four - point Bending Tester | Standard YY/T 0591-2011: Chinese standard specifying bending fatigue test methods for intramedullary nails and locking screws, including load appl... | |
| Catheter Hydraulic Leakage Tester | The Catheter Hydraulic Leakage Tester is a testing instrument specifically developed and manufactured for leak detection and quality assessment of ... |
Same products
| 6 station tester with RS232 | 卖方: Standard International Group (HK) Limited | Application 1. Evaluating Material Fogging Performance The fogging tester is primarily used to ... | |
| high low temperature gravel impact tester for coatings | 卖方: Standard International Group (HK) Limited | Application This tester is widely applied in durability and damage resistance evaluation for mat... | |
| gravel impact tester ASTM C1620 | 卖方: Standard International Group (HK) Limited | Application 1. Automotive Industry Vehicle Body Coating Testing: Testing the chip resistance of... | |
| digital Schopper abrasion tester | 卖方: Standard International Group (HK) Limited | Applications Textile Industry: Evaluating the abrasion resistance of fabrics, carpets, curtains,... | |
| industrial abrasion testing equipment | 卖方: Standard International Group (HK) Limited | Applications The G282 Universal Abrasion Tester performs flat abrasion, curved abrasion, edge ab... |