.

Blade penetration tester for staplers

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Standards

YY/T 1797 - 2021: Surgical blades - Test method for sharpness and cutting performance

Features

1.Industrial-grade 7-inch capacitive touchscreen with a menu-driven interface for easy and intuitive operation.

2.Professional software design with multi-level access control for convenient laboratory management and standardized equipment use.

3.Supports remote upgrades and maintenance.

4.Equipped with a miniature printer for easy printing of test results.

Technical Parameters

ParameterSpecification
Testing Accuracy ±0.01N
Testing Speed 0.05–600mm/min (Some models may vary, e.g., 600mm/min±30mm/min)
Testing Material Complies with the 3-0 uncoated silk-like twisted strand suture specified in YY0167-2005 (or other standard testing materials)
Power Supply 220V 50Hz; Overall Power Consumption: 70W (or other values)
External Dimensions 400×290×275mm (or other dimensions)
Net Weight 15kg (or other values)

Accessoriess

Standard configuration: Main unit, mini printer

Optional accessories: Professional software, communication cable

Test Procedures

1. Pre-test Preparation

Check the instrument's power supply (220V 50Hz) and component connections to ensure they are functioning correctly. Start the instrument and allow it to warm up to a stable operating state;

Calibrate the force sensor (ensuring an accuracy of ±0.01N), and prepare the test materials (such as 3-0 uncoated silk twisted suture as specified in YY0167-2005).

2. Sample and Test Medium Installation

Fix the stapler blade to be tested onto the instrument's dedicated fixture, ensuring the blade angle, position, and cutting path are aligned and there is no looseness/offset;

Install the test medium (such as standard suture) onto the cutting platform, adjusting its position to precisely align with the cutting edge of the blade.

3. Test Parameter Settings

Using the touchscreen interface, select the appropriate standard (YY/T 1797-2021), set the test speed (e.g., 0.05–600 mm/min), data acquisition frequency, and other parameters. Confirm and save the configuration.

4. Starting the Test

After confirming that the blade and medium are correctly positioned, click the "Start" button. The instrument will automatically simulate the cutting process, collecting and displaying cutting force, displacement, and other data in real time.

5. Test Process Monitoring

Observe the data changes on the interface to ensure that there are no abnormalities during the cutting process (such as blade jamming or medium displacement). If problems occur, pause and adjust immediately.

6. Test Completion and Cleanup

After the test is completed, the instrument will automatically shut down. Record/export the sharpness-related data (such as initial cutting force and displacement curve);

Loosen the fixture to remove the blade and remaining test medium, clean the fixture and cutting platform, turn off the instrument's power, and prepare the test report.


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Syringe needle flow tester
Syringe needle flow tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Syringe Needle Flow Tester is designed to evaluate the flow characteristics of syringes...
 fingertip hand abrasion tester
fingertip hand abrasion tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Functionality of a product is considered as a matter of course, so the perception of qualit...
Coating abrasion resistance test device
Coating abrasion resistance test device Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Introduction: The determination of scratch resistance of the coating is very simil...
High-pressure environmental friction and wear tester
High-pressure environmental friction and wear tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (GB/T 12583) Technical Conditions for Rubber and Plastic Testing Machines &mdash...
Catheter Leakage and Compliance Tester
Catheter Leakage and Compliance Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The catheter leakage and compliance tester is mainly used to detect the leaka...
供应产品

Same products

HDPE高速水冷双壁波纹管生产线
HDPE高速水冷双壁波纹管生产线 卖方: Shandong HUASU Plastic Technology Co.,Ltd. 机头模具采用双流道结构、氮化磨光处理机头,偏壁调整方便快捷,保证内外层壁厚均匀和稳定成型。 最新设计密闭压力水冷冷却结构,冷却充分,多点分布真空系统,效率更高,生产速度更快。 双层在线扩口功...
PanEVAP & MVR system
PanEVAP & MVR system 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd A multiple-effect evaporator is a device that efficiently uses steam heat to evaporate water. Wat...
PanGAP wide gap welded plate heat exchanger
PanGAP wide gap welded plate heat exchanger 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanGAP wide gap welded plate heat exchangerconsists of a welded plate pack with different channel...
PanBloc welded plate heat exchanger
PanBloc welded plate heat exchanger 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanBloc welded plate heat exchangeris compact and efficient, although fully welded, is totally ac...
PanBox welded plate heat exchanger
PanBox welded plate heat exchanger 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanBox welded plate heat exchangerconsists of a laser welded plate pack with optimized corrugated...