Aluminum ointment tube compression strength tester
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
The design and manufacture of the ductility tester for aluminum tubes usually comply with a series of national and international standards to ensure the accuracy and reliability of test results. Among them, common standards include YBB00162002 - 2015 Aluminum Pharmaceutical Soft Tubes, etc. These standards specify in detail the test methods for the ductility of aluminum tubes, specimen preparation, test conditions, etc., providing a unified standard for the use of the tester.
Features
Designed strictly according to national or industry standards, it meets standard testing requirements, ensuring compliant test results and accommodating all hose specifications.
Utilizing a high-precision measurement system, it accurately reads the gate's scale markings, thus quantifying the aluminum tube's toughness.
Made of 304 stainless steel with electroplating, it boasts a beautiful appearance and high material strength.
Technical Parameters
| Technical Parameter | Specification |
|---|---|
| Measurement Range | Usually applicable to aluminum soft tubes with a diameter between 10 and 45mm (some devices cover 8-45mm) and a certain tube length; covers most common aluminum tube specifications for wide applicability. |
| Gate Plate Weight | Precisely controlled within 70g±1g (a key pressure-applying component, ensuring testing consistency and accuracy). |
| Testing Accuracy | Equipped with a high-precision measurement system (e.g., current measurement accuracy reaches ±0.1mA) to quantify aluminum tube deformation under external forces (specific accuracy varies by device). |
| Automation Level | Adopts automatic and intelligent technologies; features one-click operation, automatic timing, and data recording to reduce operator burden and improve test accuracy/traceability. |
| Appearance Dimensions and Weight | Usually compact and portable (varies by model/brand), enabling use in different production sites and laboratories for flexible, convenient testing. |
| Working Environment | Requires a specific environment: working temperature 23℃±2℃, relative humidity ≤80% (no condensation); ensures equipment stability and test result accuracy. |
Accessoriess
Standard configuration: Main unit
Test Procedures
Select a suitable stepped support.
Place the sample onto the mandrel, with the tail end of the tube fitted onto the first-level step corresponding to the aluminum tube's specifications. The mandrel should extend from the nozzle. The aluminum tube should remain perpendicular to the base throughout the test. Place the top pressure plate over the extended mandrel and gently rest it on the top of the nozzle. Apply uniform pressure to the pressure plate and quickly press the aluminum tube downwards. The aluminum tube should exhibit a uniformly folded "accordion" shape. Remove the pressed aluminum tube from the mandrel and stretch it as close to its original length as possible. Cut it longitudinally and observe the surfaces of the inner and outer coatings. There should be no cracks or peeling in the inner and outer coatings.
在线联系供应商
Other supplier products
| Helmet Projection and Surface Friction tester | The helmet projection and surface friction tester is a device used to test the frictional force between the helmet surface and other objects. Its m... | |
| Rolling Contact Fatigue Testing Machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application Rolling Contact Fatigue Research Evaluation of rolling contact fatigue (RCF) ... | |
| Rubber Sleeve Rebound Tester | The Rubber Sleeve Rebound Tester is designed to evaluate the resilience and compression performance of collection needle rubber sleeves. It measure... | |
| Nasal Oxygen Cannula Tester | This device is used to test various performance characteristics of nasal cannulas, such as airflow resistance and resistance to kinking. It is also... | |
| Fourier Transform Infrared Smoke Toxicity Measurement Equipment | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The FTIR smoke toxicity test system is suitable for a wide range of gas analys... |
Same products
| Surface adhesion testing equipment factory price | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards JIS L 1066 (Testing Methods fo... | |
| Continuous load scratch resistance tester manufacturer | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ISO DIS 12137-2 (Plastics &mda... | |
| High precision continuous load surface tester | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB/T 6040-2008 Test Method for... | |
| Multi-function surface performance test system | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB/T 6040-2008 Test Method for... | |
| Laboratory tribology research equipment | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB/T 6040-2008 Test Method for... |