Accelerated oxidation tester
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Differential Scanning Calorimeter DSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control. DSC research and development includes the following field: glass transition temperature, melting point, cold crystallization, crystallization, phase transition, Enthalpy, oxidation induction time (OIT).
Application
It is used to determine the time of automatic catalytic oxidation of the sample at room temperature hydrogen, and to evaluate the thermal stability of the sample. It is suitable for plastics and rubber materials.
Standard
GB/T17391-1998:Polyolefin pipe systems for the conveyance of fluids under pressure - Test methods for the resistance to internal pressure
ISO/TR10837:1991:Technical Report on the use of plastics pipes and fittings for the conveyance of drinking water - Guidelines for the selection of materials and components
ASTM D3895-1998:Standard Test Method for Oxidative Induction Time of Polyolefins by Differential Scanning Calorimetry (DSC)
ASTM E 967:Standard Practice for Temperature Calibration of Thermocouples and Thermocouple Materials by Comparison Techniques
ASTM E 968:Standard Practice for Thermal Cycling of Electronic Components and Materials for Temperature Stress Screening
ASTM E 793:Standard Test Method for Measuring Surface Discontinuities on Metal Surfaces by Electromagnetic (Eddy-Current) Method
ASTM D 3895:Standard Test Method for Oxidative Induction Time of Polyolefins by Differential Scanning Calorimetry (DSC)
ASTM D 3417:Standard Test Method for Thermogravimetric Analysis (TGA) of Polymers
ASTM D 3418:Standard Test Method for Transition Temperatures and Enthalpies of Fusion and Crystallization of Polymers by Differential Scanning Calorimetry (DSC)
ISO 11357-6:Plastics - Differential scanning calorimetry (DSC) - Part 6: Determination of oxidation induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT)
EN 728:Thermal insulating products for building applications - Determination of water vapour transmission properties
Features
The instrument has stable performance, high measurement accuracy and good repeatability;
Designed for measuring oxidation induction period in plastics and rubber industry:
* Integrated design, temperature control and furnace device are integrated, reducing signal loss and interference, beautiful and exquisite appearance;
The furnace body adopts the upper cover structure, no need to lift, convenient loading sample;
* High-resolution data acquisition system, real-time data acquisition;
Intelligent adaptive single-chip microprocessor temperature control system, temperature control speed, high precision:
* Perfect two-way air valve control system, using the original imported flow valve from the United States, can realize the automatic switching of ammonia to oxygen during the measurement process;
Professional oxidation induction period test software with automatic temperature correction and automatic test program to automatically calibrate temperature, test oxidation induction time and plot curves:
Simple operation method, to achieve one-click testing, test results can be saved and printed:
Computer real-time display instrument status, test data and curves, easy to view.
Parameters
| Description | Details |
|---|---|
| Maximum tensile stress | 20MPa |
| Number of stations | 30 (can be customized) |
| Water bath temperature range | RT - 90°C |
| Temperature control accuracy | ±1°C |
| Switch sensitivity | 200g |
| Timing accuracy | 1s |
| Sample thickness | 0.75 - 3mm |
| Notch depth | 20% of the nominal thickness of the sample (6 - specified as an example value, if relevant) |
| Power supply | AC 380V 50HZ |
| Overall dimensions | 1420x640x1900mm |
| Weight | 380kg |
在线联系供应商
Other supplier products
| ASTM E84 Steiner Tunnel Test Installation | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application Interior and exterior building materials: Testing flame spread performance of ... | |
| Industrial chillers | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ASHRAE 15(Safety Standard for Refrigeration Systems) ISO 5149(Refrigerating S... | |
| Wire Torsion Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applicable standards: GB/T 239.1-2012 "Metal materials wire Part I unidirectional torsion ... | |
| UV Condensation Aging Test Chamber丨UV Condensation Aging Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ASTM G154.ISO 4892-3.JIS K 7350. andSAE J2020for UV exposure testing. IEC 60068-... | |
| Mask Synthetic Blood Penetration Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Medical Face Mask Synthetic Blood Penetration Resistance Tester Medical masks synthetic bl... |
Same products
| 不锈钢焊剂芯焊丝 E308T1-1 E308HT1-1 E308LT1-1 用于304不锈钢焊接的气保焊丝 | 卖方: 863048 | 产品描述 不锈钢药芯焊丝 E308T1-1 E308HT1-1 E308LT1-1,FCAW不锈钢焊丝,AWS A5.22药芯焊丝,304不锈钢焊接耗材,低碳不锈钢药芯焊丝,耐高温不锈钢焊丝,... | |
| E317LT1-1 焊剂芯线 CO2 不锈钢焊剂含量70% 直径1.0/1.2/1.6mm OEM定制 1200℃熔点 | 卖方: 863048 | 迅卓不锈钢药心焊丝 E317LT1-1 分类: Сварочная проволока E317LT1-1 с флюсом, нержавеющая сталь, 70% содержан... | |
| Mini Jewelry Laser Repair System – 60W to 400W Precision Welding | 卖方: Beijing JCZ Technology Co., Ltd | The Mini Jewelry Laser Welding Machineis an advanced mini laser welding system engineered for pre... | |
| Portable Backpack Laser Cleaning Machine – Lightweight, Efficient Rust & Paint Removal | 卖方: Beijing JCZ Technology Co., Ltd | TheHCP-M SeriesBackpack Laser Cleaning Machinefeatures a compact pulsed fiber laser system, desig... | |
| Suitcase Pulsed Laser Cleaning Machine | Ultra-Portable Handheld Fiber Laser Cleaner | 卖方: Beijing JCZ Technology Co., Ltd | The Suitcase Pulsed Laser Cleaning Machineis an ultra-portable, high-precision handheld fiber las... |