Vehicle-Level High/Low Temperature and Humidity Test Chamber
Get a quote:
Whats/App: +86 181 0160 0864
TheVehicle-Level High/Low Temperature and Humidity Test Chamberis a large-scale environmental simulation chamber designed to replicate extreme temperature and humidity conditions for full vehicles and automotive components. You can use it to verify the performance reliability of engines, air conditioning systems, electrical components, coatings, and rubber parts under high and low temperature, as well as humid environments. This chamber is essential for automotive research, development, and quality control.
Applications
1. Automotive R&D Testing
Cold Start Test: Verifies engine starting performance at low temperatures (e.g., -40°C), requiring ≤3 successful starts with a start time ≤15 seconds.
Thermal Equilibrium Test: Simulates high-temperature (+60°C) and high-humidity environments to evaluate the stability of air conditioning systems and cooling components.
Material Reliability: Assesses the aging resistance of body coatings and rubber seals under temperature-humidity cycling conditions.
2. Other Applications
Extendable for environmental reliability testing in aerospace, large home appliances, and other industries, supporting composite environment simulation including low atmospheric pressure (1 kPa to atmospheric pressure).
Standards
GB/T 2423.1 Environmental Testing of Electrical and Electronic Products - Part 2: Test Methods - Test A: Low Temperature
GB/T 2423.2 Environmental Testing of Electrical and Electronic Products - Part 2: Test Methods - Test B: High Temperature
GB/T 2423.3 Environmental Testing - Part 2: Test Methods - Test Cab: Constant Humidity and Heat Test
GJB 150.3A Laboratory Environmental Test Methods for Military Equipment - Part 3: High Temperature Test
GJB 150.4A Laboratory Environmental Test Methods for Military Equipment - Part 4: Low Temperature Test
Features
1.Large-Scale Vehicle Testing:
Supports full-size vehicles and engine operation under extreme temperature and humidity conditions.
2.Precise Environmental Control:
Temperature fluctuation ≤±0.5℃, temperature uniformity ≤2℃, and humidity deviation ±5% RH ensures reliable and repeatable results.
3.Cold Start and Heat Balance Simulation:
Allows testing of automotive engines, air conditioning systems, and auxiliary components under simulated real-world conditions.
4.Durability and Reliability Assessment:
Facilitates accelerated aging of coatings, rubber seals, and electrical components under extreme environmental cycles.
5.Flexible Application:
Can be adapted to composite environmental simulations including low-pressure conditions for aerospace or industrial applications.
Parameters
| Item | Specifications |
|---|---|
| Refrigeration System | Capable of maintaining stable internal temperature at -16°C while one 5-ton vehicle (or two 2.5-ton vehicles, total engine displacement 4.0T, maximum power 300kW) is running at 50% rated engine speed.Internal effective dimensions: 10 m × 5 m × 4 m (D × W × H) |
| Temperature Range | -45°C ~ 90°C |
| Temperature Fluctuation | ≤±0.5°C |
| Temperature Uniformity | ≤2°C |
| Humidity Range | 20% ~ 98% RH |
| Humidity Deviation | ±5% |
Accessories
Programmable touchscreen control system
Humidity and temperature sensors
Data acquisition and monitoring software
Vehicle support platforms or wheel locking fixtures
Safety interlocks and alarm systems
Test Procedures
1. 1.Equipment Preparation
Verify chamber structure, power supply, and safety interlocks.
Check water supply and humidity system operation.
Position vehicle(s) securely using support platforms or fixtures.
2. 2.Parameter Configuration
Set desired temperature and humidity ranges.
Program cyclic test schedules for hot, cold, and humid conditions.
Activate data acquisition and monitoring systems.
3.3. Test Execution
Start environmental simulation.
Monitor temperature, humidity, and engine behavior if performing cold start tests.
Record all data automatically via software.
4.4. Test Completion
Gradually return chamber to ambient conditions.
Remove vehicles safely and analyze test data for component reliability and performance.
在线联系供应商
Other supplier products
| Infusion Pump Flow Rate Tester | Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The Infusion Pump Flow Rate Tester is specifically designed for testing the flow r... | |
| Qinsun Xenotest 220 | Standards ISO 105-B02: Lightfastness testing for colored textiles. AATCC TM16 (Option 3): Accelerated weathering for textiles under controlle... | |
| Bag lifting fatigue testing machine / Bag Fatigue Testing Machine | Product Introduction: This machine is suitable for up and down vibration fatigue test of plastic handbag, garbage vest bag, kraft paper bag, woven... | |
| Safety Footwear Compression Puncture Tester/ Compression & Penetration Resistance Tester | Test purpose Measure the compression resistance of the shoe head cover and the puncture resistance of the steel plate to prevent the operator from... | |
| High-Low Temperature Gravel Impact Tester | Get a quote: Whats/App: +86 181 0160 0864 High-Low Temperature Multifunctional Aggregate Impact Tester is a professional testing instrument desig... |
Same products
| Common Rail Injector Valve F00R J02 012 | 卖方: 868983 | Common Rail Injector Valve F00R J02 012 David Chen | |
| Common Rail Injector Valve F00R J02 005 | 卖方: 868983 | Common Rail Injector Valve F00R J02 005 David Chen | |
| Common Rail Injector Valve F00R J01 945 | 卖方: 868983 | Common Rail Injector Valve F00R J01 945 David Chen | |
| Common Rail Injector Valve F00R J01 941 | 卖方: 868983 | Common Rail Injector Valve F00R J01 941 David Chen | |
| Common Rail Injector Valve F00R J01 924 | 卖方: 868983 | Common Rail Injector Valve F00R J01 924 David Chen |