ASTM D3895 Compliant OIT Measurement System

Get a quote:

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Application

It is used to determine the time of automatic catalytic oxidation of the sample at room temperature hydrogen, and to evaluate the thermal stability of the sample. It is suitable for plastics and rubber materials.

Standard

GB/T17391-1998:Polyolefin pipe systems for the conveyance of fluids under pressure - Test methods for the resistance to internal pressure

ISO/TR10837:1991:Technical Report on the use of plastics pipes and fittings for the conveyance of drinking water - Guidelines for the selection of materials and components

ASTM D3895-1998:Standard Test Method for Oxidative Induction Time of Polyolefins by Differential Scanning Calorimetry (DSC)

ASTM E 967:Standard Practice for Temperature Calibration of Thermocouples and Thermocouple Materials by Comparison Techniques

ASTM E 968:Standard Practice for Thermal Cycling of Electronic Components and Materials for Temperature Stress Screening

ASTM E 793:Standard Test Method for Measuring Surface Discontinuities on Metal Surfaces by Electromagnetic (Eddy-Current) Method

ASTM D 3895:Standard Test Method for Oxidative Induction Time of Polyolefins by Differential Scanning Calorimetry (DSC)

ASTM D 3417:Standard Test Method for Thermogravimetric Analysis (TGA) of Polymers

ASTM D 3418:Standard Test Method for Transition Temperatures and Enthalpies of Fusion and Crystallization of Polymers by Differential Scanning Calorimetry (DSC)

ISO 11357-6:Plastics - Differential scanning calorimetry (DSC) - Part 6: Determination of oxidation induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT)

EN 728:Thermal insulating products for building applications - Determination of water vapour transmission properties

Features

The instrument has stable performance, high measurement accuracy and good repeatability;

Designed for measuring oxidation induction period in plastics and rubber industry:

* Integrated design, temperature control and furnace device are integrated, reducing signal loss and interference, beautiful and exquisite appearance;

The furnace body adopts the upper cover structure, no need to lift, convenient loading sample;

* High-resolution data acquisition system, real-time data acquisition;

Intelligent adaptive single-chip microprocessor temperature control system, temperature control speed, high precision:

* Perfect two-way air valve control system, using the original imported flow valve from the United States, can realize the automatic switching of ammonia to oxygen during the measurement process;

Professional oxidation induction period test software with automatic temperature correction and automatic test program to automatically calibrate temperature, test oxidation induction time and plot curves:

Simple operation method, to achieve one-click testing, test results can be saved and printed:

Computer real-time display instrument status, test data and curves, easy to view.

Parameters

DescriptionDetails
Maximum tensile stress 20MPa
Number of stations 30 (can be customized)
Water bath temperature range RT - 90°C
Temperature control accuracy ±1°C
Switch sensitivity 200g
Timing accuracy 1s
Sample thickness 0.75 - 3mm
Notch depth 20% of the nominal thickness of the sample (6 - specified as an example value, if relevant)
Power supply AC 380V 50HZ
Overall dimensions 1420x640x1900mm
Weight 380kg

Accessoriess

1. Main unit: 1 set

2. Standard indium sample: 0.5g

3. Standard tin sample: 0.5g

4. Aluminum crucibles: 200 pieces

5. Software USB drive: 1 piece

6. Pressure reducing valves: 2 pieces

7. Power cord: 1 piece

8. Communication cable: 1 piece

9. Gas tubes: 3 pieces

10. Gas tube connectors: 2 pieces

11. Tweezers: 1 piece

12. Sampling spoon: 1 piece

13. Fuses: 4 pieces

14. Computer (provided by the customer): 1 set

15. Printer (provided by the customer): 1 set

16. Product packing list: 1 copy

17. Product manual: 1 copy

18. Product certificate of conformity: 1 copy


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Automatic oxidizing liquid tester apparatus
Automatic oxidizing liquid tester apparatus Whats/App: +86 156 1874 6768 Web: standard-groups.com Conforms to UN Recommendations on the Transport of Dangerous Goods - Manual of Tests and Cr...
Snap Button Tester
Snap Button Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Snap Button Tester is a device specifically designed to test the durability of buttons ...
Fiber Crimp Elasticity Tester
Fiber Crimp Elasticity Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Fiber Crimp Elasticity Tester is a specialized instrument designed to measure the crimp...
High-precision thermal conductivity tester for silicone and ceramic materials
High-precision thermal conductivity tester for silicone and ceramic materials Whats/App: +86 156 1874 6768 Web: standard-groups.com Application This tester is suitable for testing: Thin heat conductors and metals Solid e...
UV curing light box
UV curing light box Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ISO 10977: Adheres to industrial standards for UV curing of adhesives and coating...
供应产品

Same products

MMA-120 Handheld Arc Welder
MMA-120 Handheld Arc Welder 卖方: 871183 The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con...
SHX Series Circulating Fluidized Bed Steam Boiler
SHX Series Circulating Fluidized Bed Steam Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi...
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ...
DHL Series Coal-Fired Steam Boilers
DHL Series Coal-Fired Steam Boilers 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b...
SZL Series Biomass Steam Boiler
SZL Series Biomass Steam Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi...