Autocatalytic Decomposition Temperature Tester with Thermal Insulation

Get a quote:

Whats/App: +86 181 0160 0864

Web: gellowen.co.uk

The Autocatalytic Decomposition Temperature Tester with Thermal Insulation (Adiabatic SADT Tester) is a critical instrument for evaluating the thermal hazards of energetic chemicals. By precisely determining the rate of heat generation as a function of temperature under adiabatic conditions, this equipment allows you to calculate the Self-Accelerating Decomposition Temperature (SADT). This data is essential for characterizing how a substance behaves within its packaging, ensuring safety during transport and storage. Whether you are dealing with IBCs, tanks, or small containers, this tester provides the foundational thermal loss data required to prevent catastrophic thermal runaway.

Applications

The Autocatalytic Decomposition Temperature Tester with Thermal Insulation is a core device for assessing the thermal hazards of chemicals, used to determine a substance's heat release rate as it changes with temperature. The measured heat release parameters, combined with thermal loss data for the relevant package, are used to determine the substance's autocatalytic decomposition temperature within its container. This method is applicable to all types of containers, including intermediate bulk containers and tanks.

Features

1) Embedded processor with Windows CE operating system.

2) 8-inch LCD touchscreen for real-time display of test status.

3) Built-in air circulation system ensures uniform and stable chamber temperature.

4) Digital PID algorithm precisely controls heating temperature with high accuracy.

5) Equipped with a cooling system to prevent sample overheating and potential explosions.

6) Auxiliary safety device provides overheat protection, automatically shutting off the heating system at a predetermined temperature.

7) Instrument fault detection and audible/visual alarm functions ensure enhanced test safety.

8) Features an explosion-proof glass observation window on the front and a pressure relief door on the rear. Internal thrust exceeds 2.5 kgf; opening the pressure relief door ensures safer testing.

9) Displays real-time operating duration and temperature, automatically plots test curves, and allows access to raw data.

10) Offers versatile test selection; users can configure parameters based on sample characteristics.

11) Fully automated testing process requires no manual intervention, supporting parameter settings, data storage, and report viewing.

Parameters

Item Specifications
Operating Environment (-5 ~ 45)°C, <95% RH
Chamber Temperature Control Range -20°C ~ 220°C
Temperature Control Accuracy ±1°C
Sample Temperature Measurement Range (-50 ~ 500)°C
Sample Temperature Measurement Resolution 0.1°C
Sample Temperature Measurement Accuracy ±(2.5或0.0075×|t|)℃
Dewar Flask Capacity 1 L
Constant Power Adjustment Range 0.1W ~ 2W
Constant Power Accuracy ≤0.015W
Temperature Rise Rate Range 0 ~ 2°C
Refrigerant Circulation Rate ≥3 L/min
Dewar Flask Material Glass inner liner
Instrument Dimensions (L×W×H) 930mm × 545mm × 875mm

在线联系供应商

至: Standard Group (Hong Kong) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Prefilled Syringe Plunger Force Tester
Prefilled Syringe Plunger Force Tester Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The Prefilled Syringe Plunger Force Tester is widely used in the medical device in...
Shoelace Abrasion Tester / SATRA TM93
Shoelace Abrasion Tester / SATRA TM93 Application: This shoelace abrasion tester is used for shoelace against standard eyelet abrasion testing, or eyelet against standard shoelace abra...
Liquid Autoignition Point Tester
Liquid Autoignition Point Tester Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The Liquid Autoignition Point Tester is a device used to determine the lowest temp...
Arc Resistance Tester
Arc Resistance Tester Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk Arc Resistance Tester is a special instrument necessary for simulated safety test ...
Fully Automatic Dual-Plate Thermal Conductivity Tester (Guarded Hot Plate Method)
Fully Automatic Dual-Plate Thermal Conductivity Tester (Guarded Hot Plate Method) Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk Fully Automatic Dual-Plate Thermal Conductivity Tester (Guarded Hot Plate Method) ...
供应产品

Same products

Common Rail Injector Valve F00R J02 012
Common Rail Injector Valve F00R J02 012 卖方: 868983 Common Rail Injector Valve F00R J02 012 David Chen
Common Rail Injector Valve F00R J02 005
Common Rail Injector Valve F00R J02 005 卖方: 868983 Common Rail Injector Valve F00R J02 005 David Chen
Common Rail Injector Valve F00R J01 945
Common Rail Injector Valve F00R J01 945 卖方: 868983 Common Rail Injector Valve F00R J01 945 David Chen
Common Rail Injector Valve F00R J01 941
Common Rail Injector Valve F00R J01 941 卖方: 868983 Common Rail Injector Valve F00R J01 941 David Chen
Common Rail Injector Valve F00R J01 924
Common Rail Injector Valve F00R J01 924 卖方: 868983 Common Rail Injector Valve F00R J01 924 David Chen