Building Material Non-Combustibility Test Furnace Factory

Get a quote:

Whats/App: +86 156 1874 6768

Web: standard-groups.com

E-mail:info@standard-groups。com

Control System

1. High degree of automation, test procedure safe and reliable, easy to operate;

2. To use of high-quality strip heater,furnace temperature was raised to 900 ºC;

3. PLC control system + SSR temperature control system extending the life of furnace;

4. PLC output signal to control the heating voltage is 0-110 VAC. Eliminate the influence of voltage fluctuation on temperature;

5. Temperature control: 750 ºC±2 ºC;Resolution:0.1ºC;

6. The samplies move up-down into the furnace automatically by motor;

7. 7 "touch screen for control parameter setting and display / test data acquisition and preservation / screen monitoring / real-time temperature curve shows / historical curve and data query;

8. With an audible alarm and alarm display functions accidents;

9. To equipped with printer, to print the temperature curve;

Parameters

ItemSpecification
Gas used - Methane flow rate (35 ± 0.5) L/min, purity > 95%
Gas used - Air flow rate (17 ± 0.2) L/min
Specimen size 4 specimens per test group
Thermocouple type Nickel-chromium-nickel-silicon, wire diameter 0.5mm, outer diameter ≤ 3mm
Furnace wall temperature range Room temperature to 100°C, ±1°C
Intake temperature range 0 to (50 ± 0.5)°C
Pressure difference range 0 to 30Pa, ±1Pa
Pressure difference measurement range 0-100Pa, accuracy 0.2%
Temperature recorder and thermostat Multi-channel continuous temperature recording and curve display
Constant temperature (23 ± 2)°C
Constant current (10 ± 1) m³/min
Ambient temperature range 19 to 30°C
Power supply 380VAC 50HZ
Dimensions of combustion shaft furnace (outer) 1020mm x 1020mm x 3930mm
Dimensions of combustion shaft furnace (inner) 800mm x 800mm x 2000mm

Accessoriess

Complete set includes:

01. European standard indoor furnishings flammability testing kit

02. No. 4 wooden spacers (10 pieces/pack)

03. No. 5 wooden spacers (10 pieces/pack)

04. No. 6 wooden spacers (10 pieces/pack)

05. No. 7 wooden spacers (10 pieces/pack)

06. Non-flame retardant polyurethane foam 450×450

07. Non-flame retardant polyurethane foam 450×300

08. Non-flame retardant polyurethane foam 450×150

09. Flame retardant polyurethane foam 450×450

10. Flame retardant polyurethane foam 450×300

11. Flame retardant polyurethane foam 450×150

12. Flame retardant polyurethane foam 450×450

13. Flame retardant polyurethane foam 450×300

14. Flame retardant polyurethane foam 450×150

15. Standard cigarettes (10 packs)

Test Procedures

1. So that the furnace temperature equilibrium, if the logger can not be calculated in real time, the final temperature should be checked whether the balance.

2. Before the test should ensure that the entire device is in good working condition, such as a steady flow clean air flow, the device can be smoothly inserted into the slide, the sample holder can be accurately located in a predetermined position in the furnace.

3. Prepared according to a predetermined and regulated by the state of the sample into the sample holder, the sample racks suspended from the support member. The sample holder into a predetermined position in the furnace, the operation time should not exceed 5s. When the sample is located in a predetermined position in the furnace, immediately start the timer. Recorded during the test furnace thermocouple temperature measurement, such as the requirement to measure the surface temperature of the sample and the center temperature, corresponding to the temperature it should also be recorded.

4. Carried 30min test, if the furnace temperature reaches the final equilibrium temperature in 30min, that is measured by a thermocouple temperature drift (linear regression) within 10min of not more than 2 ℃, you can stop the test. If unable to reach equilibrium within 30min, the test should be continued, while every 5min check whether the final temperature equilibrium, when the furnace temperature reaches a final equilibrium temperature or testing time reaches 60min end of the trial should be. Recording duration of the test, the sample holder and then remove from the heating furnace, the end of the time trial for the end time of the last 5min or 60min. Temperature should be checked after the end of the test record if the logger can not be recorded in real time, test. If it can not meet the above requirements, it should be re-tested. If an additional test using a thermocouple, the thermocouple should all have reached the final temperature equilibrium or when the test time was 60min when the end of the trial.

5. The collection and after the test specimen cracked or falling all carbides, ash and other debris, together with the sample into the drying vessel was cooled to ambient temperature, weigh the residual mass of the sample. The quality of each sample were recorded before and after the test and observing the combustion behavior recorded during the test specimen. Sustained fire occurrence and duration records, accurate to the second. Sample shows a continuing 5s or longer continuous flame on the surface it should be regarded as sustained fire.

6. The following furnace thermocouple to measure the temperature, in degrees Celsius, the initial furnace temperature T1. average temperature last 10min predetermined temperature balance of the furnace; furnace maximum temperature Tm, the maximum temperature throughout the test discrete value; the final furnace temperature Tf ,. The temperature during the test last 1min average.

Fourth, the end of the trial, finishing the test furnace wipe clean for the next use.


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Mask respiratory resistance tester
Mask respiratory resistance tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Mask Respiratory Resistance Tester is designed to measure the inhalation and exhalation...
Stick Slip Test Stand for Material Combinations(G-SSP),Stick-slip behavior testing equipment
Stick Slip Test Stand for Material Combinations(G-SSP),Stick-slip behavior testing equipment Whats/App: +86 156 1874 6768 Web: standard-groups.com The Stick-Slip Tribological Test Stand is a laboratory testing system used to evaluate fric...
Bending Tester STD- FB2 - S
Bending Tester STD- FB2 - S Whats/App: +86 156 1874 6768 Web: standard-groups.com Compliance Standards ASTM D790 (Plastics Flexural Properties) ISO 178 (Flexural Strength ...
Perspiration Tester 丨Perspiration Test machine
Perspiration Tester 丨Perspiration Test machine Whats/App: +86 156 1874 6768 Web: standard-groups.com Compliant Standards ISO 105 E01: Textiles - Tests for colour fastness - Part E01: Colour f...
Liquid Sustained Combustion Tester
Liquid Sustained Combustion Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Introduction This product complies with "Recommendations on the Transport of Dange...
供应产品

Same products

ER4043 Silicon Aluminum Welding Wire
ER4043 Silicon Aluminum Welding Wire 卖方: 868776 Hangzhou Kunli Welding Materials Co., Ltd. offers ER4043 Silicon Aluminum Welding Wire for alumin...
HDPE高速水冷双壁波纹管生产线
HDPE高速水冷双壁波纹管生产线 卖方: Shandong HUASU Plastic Technology Co.,Ltd. 机头模具采用双流道结构、氮化磨光处理机头,偏壁调整方便快捷,保证内外层壁厚均匀和稳定成型。 最新设计密闭压力水冷冷却结构,冷却充分,多点分布真空系统,效率更高,生产速度更快。 双层在线扩口功...
PanEVAP & MVR system
PanEVAP & MVR system 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd A multiple-effect evaporator is a device that efficiently uses steam heat to evaporate water. Wat...
PanGAP wide gap welded plate heat exchanger
PanGAP wide gap welded plate heat exchanger 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanGAP wide gap welded plate heat exchangerconsists of a welded plate pack with different channel...
PanBloc welded plate heat exchanger
PanBloc welded plate heat exchanger 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanBloc welded plate heat exchangeris compact and efficient, although fully welded, is totally ac...