LSFT Large-Scale Fire Test System Manufacturer | Fire Dynamics & Heat Release Test Equipment
Get a quote:
Whats/App: +86 156 1874 6768
Web: standard-groups.com
E-mail:info@standard-groups。com
Parameters
| Item | Specification |
|---|---|
| Footprint | Determined by actual test requirements |
| Electrical Load | Determined by actual test requirements |
| Heat Release Rate Measurement | Supports up to 20 MW stable combustion tests |
| Gas Analysis | Multi-functional gas analyzers including FTIR, total hydrocarbon analyzers, and sensors |
| Data Acquisition | 300+ temperature channels, 30+ voltage channels, optional 2–8 high-frequency pressure channels |
| Fire Triggering | 4+ heating channels, 8-channel high-voltage spark, 8-channel silicon nitride igniters |
| Monitoring | Thermal imaging infrared cameras, explosion-proof cameras, video recorders, optional high-speed or drone cameras |
| Environmental Monitoring | Temperature, humidity, atmospheric pressure, wind speed, wind direction |
Test Procedures
Site Preparation: Configure the testing area according to fire test requirements and ensure safety systems are in place.
Sample Installation: Mount the energy storage system or container on the movable calorimetric structure.
Environmental Setup: Verify environmental parameters and ensure exhaust systems are operational.
System Configuration: Program data acquisition channels, gas analyzers, and fire triggering devices according to the test plan.
Initiate Fire Test: Trigger external flame attack or internal battery thermal runaway using heating channels, sparks, or igniters.
Real-Time Monitoring: Observe heat release rate, gas composition, smoke opacity, duct parameters, and structural response.
Data Recording: Capture video, thermal imaging, and all sensor data.
Test Completion: Safely extinguish flames, allow cooling, and retrieve test samples. Export data for analysis.
Maintenance Information
Inspect calorimetric structures, fire containment walls, and igniters for integrity before each test.
Maintain exhaust purification units by cleaning water film scrubbers, activated carbon filters, and electric separators regularly.
Calibrate sensors, data acquisition systems, and gas analyzers periodically.
Verify heating channels, spark generators, and igniters for operational readiness.
Backup all acquired data and system logs to ensure traceability and compliance documentation.
在线联系供应商
Other supplier products
| Best Cable Fire Safety Tester for Electrical Insulation | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Cable and Fiber Optic Cable Line Integrity Combustion Testing Machine is ... | |
| Catheter Vacuum Leak Tester ISO & ASTM Standard | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Catheter Vacuum Leak Tester is a professional device used to detect leaks... | |
| High temperature vacum Friction and Wear Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application Friction and wear performance testing of metal materials, ceramic materials, a... | |
| Chest Drainage Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The thoracic drainage tester is widely applied in the medical field, mainly used for monito... | |
| Shoelace Abrasion Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Shoelace Abrasion Tester is designed to evaluate the wear resistance of shoelaces and e... |
Same products
| MMA-120 Handheld Arc Welder | 卖方: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... | |
| SHX Series Circulating Fluidized Bed Steam Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi... | |
| YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ... | |
| DHL Series Coal-Fired Steam Boilers | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b... | |
| SZL Series Biomass Steam Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi... |