Electric pencil hardness tester

Get a quote:

Whats/App: +86 181 0160 0864

Web: gellowen.co.uk

The Electric Pencil Hardness Tester is designed to determine the surface hardness of coating layers applied to finished products by means of a standardized pencil scratch method. The instrument provides stable loading, constant angle, and uniform motion, ensuring accurate and repeatable hardness evaluation of painted, sprayed, or coated surfaces. It is widely used for quality control, product inspection, and coating performance assessment in electronics and appliance industries.

Application

(1) Surface hardness testing of spray coatings on consumer electronics housings (mobile shells, laptop computer shells)

(2) Hardness evaluation of coated plastic and metal parts used in home appliances (TV frames, air conditioner panels, washing machine panels)

(3) Quality control testing of decorative and protective coatings in manufacturing processes

(4) Comparative testing of different coating formulations and curing conditions

(5) Inspection of finished products for coating consistency and scratch resistance

Standards

(1) GB/T 6739-2022 — Paints and varnishes — Determination of film hardness by pencil test

(2) ISO 15184 — Paints and varnishes — Determination of film hardness by pencil test

(3) ASTM D3363 — Standard Test Method for Film Hardness by Pencil Test

Features

(1) Electric drive system ensures stable and uniform test platform movement

(2) Fixed 45° test angle in accordance with international pencil hardness standards

(3) Adjustable test loads to meet different standard requirements

(4) Simple structure and easy operation suitable for routine laboratory testing

(5) Good repeatability and reduced operator influence compared with manual testing

Parameters

ItemDescription
Test angle 45°
Test load 500 g / 750 g / 1000 g, adjustable
Platform moving speed Adjustable
Travel distance 40 mm
Test platform size Approx. 120 × 170 mm
Sample fixation Fixed platform
Power supply AC 220 V, 50 Hz

Accessories

(1) Pencil set from 6B to 6H, total 13 grades

(2) Standard load weight set

Test Procedures

(1) Prepare the coating specimen and ensure the surface is clean and fully cured

(2) Fix the specimen securely on the test platform

(3) Select the appropriate pencil grade and install it in the pencil holder

(4) Set the test load and ensure the pencil is positioned at a 45° angle

(5) Start the tester to move the platform at the specified speed over the set travel distance

(6) Inspect the coating surface for scratches or coating damage and record the highest pencil grade that does not cause failure

Maintenance Information

(1) Clean the test platform and pencil holder regularly to prevent contamination

(2) Check the pencil holder alignment and test angle periodically

(3) Inspect electrical components and moving parts for normal operation

(4) Store the instrument in a dry, dust-free environment when not in use.


在线联系供应商

至: Standard Group (Hong Kong) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Flammability Limits Tester
Flammability Limits Tester Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The Flammability Limits Tester is designed to determine the upper and lower flamma...
Model Coin-cell Swelling System
Model Coin-cell Swelling System Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The Model Coin-Cell Swelling System is designed for in-situ measurement of thickne...
Taber 5900 Reciprocating Abraser
Taber 5900 Reciprocating Abraser Get a quote: Whats/App: +86 181 0160 0864 Fixed sample on a horizontal table, wearing it under the specified abrasive and load with the horizonta...
Bone Cement Four-Point Bending Fatigue Tester
Bone Cement Four-Point Bending Fatigue Tester Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The Bone Cement Four-Point Bending Fatigue Tester is a specialized mechanical test...
Vacuum Blood Collection Tube Suction Volume Tester
Vacuum Blood Collection Tube Suction Volume Tester The main uses, compliance standards, and technical parameters of the Vacuum Blood Collection Tube Aspiration Volume Tester are as follows: Complia...
供应产品

Same products

MMA-120 Handheld Arc Welder
MMA-120 Handheld Arc Welder 卖方: 871183 The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con...
SHX Series Circulating Fluidized Bed Steam Boiler
SHX Series Circulating Fluidized Bed Steam Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi...
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ...
DHL Series Coal-Fired Steam Boilers
DHL Series Coal-Fired Steam Boilers 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b...
SZL Series Biomass Steam Boiler
SZL Series Biomass Steam Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi...