Catheter bending resistance tester
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Application
The tester is suitable for a wide range of medical devices, including:
(1) Urinary catheters – testing flow performance under bending to simulate patient conditions.
(2) Drainage catheters – assessing irrigation and drainage cavities.
(3) Infusion catheters – verifying consistent fluid delivery despite bends or kinks.
(4) Preclinical research – evaluating new catheter designs for flexibility and functionality.
(5) Quality control in medical device manufacturing – ensuring compliance with product specifications.
Standards
The instrument is designed to comply with the following standards:
(1) YY/T 0325-2016: Urinary Catheters – Flow and Bending Performance (China)
(2) GB/T 15812.1-2005: Disposable Catheters – General Requirements (China)
Optional references for broader compliance:
(3) ISO 10555-3: Sterile single-use intravascular catheters – Part 3: Single-use catheters for hemodialysis
(4) ASTM F2392: Standard Test Method for Catheter Performance
Features
(1) Programmable controller with touch screen interface for easy parameter setup.
(2) Real-time monitoring of force and flow data.
(3) Automatic result evaluation with buzzer alarm for unqualified tests.
(4) Integrated printer for immediate documentation of test results.
(5) Adjustable fixtures to accommodate various catheter sizes and types.
(6) Automatic circulation of water pump to simulate physiological conditions.
(7) Dual language interface (Chinese/English) for global usability.
Parameters
| Parameter | Specification |
|---|---|
| Static level height | 1000 ± 5 mm, automatic water pump circulation (adjustable) |
| Time controller | 0 – 60 min, error ±1 s |
| Test fixture | Suitable for various catheters |
| Flow calculation method | Measuring cylinder method |
| Flow rate | > 500 mL/min |
| Overall size (L × W × H) | 400 × 290 × 240 mm |
| Control system | Programmable PLC with touch screen |
| Printing | Onboard printer for real-time test results |
Accessories
(1) Main test unit – 1 set
(2) Fixtures for various catheter types – 1 set
(3) Onboard printer paper – 1 roll
(4) Operation manual – 1 set
(5) USB storage device (optional)
在线联系供应商
Other supplier products
| Socks wear tester | The Socks Wear Tester is a specialized testing instrument designed to evaluate the wear resistance, durability, and comfort of socks material. By s... | |
| Precision Fiber Slicer | G214Precision Fiber Slicer is used to make the accurate fiber cross-sectional specimens for further inspection or research under the microscope. In... | |
| UL 2596 Torch and Grit (TaG) Tester,Test Equipment for Battery Enclosure Materials | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Gravel Flame Jet Test Apparatus is designed to evaluate battery enclosure materials und... | |
| Combined Salt Spray Test Chamber | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application This chamber is widely used in industries and laboratories to assess corrosion... | |
| Desktop Xenon lamp aging test chamber | TheXenon lamp aging test chamberis a photoaging tester for large-capacity textile testing. With additional sample light frame, temperature sensor a... |
Same products
| Medical Splint RDJ013 | 卖方: Hengshui Runde Medical Instruments Co.,Ltd | Medical Splint RDJ013 This medical aluminum splintis made of two layer IXPE and core aluminum al... | |
| Chest Seal | 卖方: Hengshui Runde Medical Instruments Co.,Ltd | Chest Seal The chest sealis an advanced occlusive wound dressing for open chest wounds. Thisches... | |
| Israel Bandage RDJ020 | 卖方: Hengshui Runde Medical Instruments Co.,Ltd | Israel Bandage RDJ020 Israel BandageRDJ020is an Israeli battle dressingwith non-adhesive dressin... | |
| Gen 7 Tourniquet RDJ006 | 卖方: Hengshui Runde Medical Instruments Co.,Ltd | Gen 7 Tourniquet RDJ006 Tourniquet Gen 7 tourniquet is a first aid and medic gearitemthat has be... | |
| First Aid Kit | 卖方: Hengshui Runde Medical Instruments Co.,Ltd | First Aid Kit This First Aid Kitis designed for rapid, effective emergency response in severe tr... |