.

Thrombite™ Clot Retriever Device

OVERVIEW

Thrombite™ Clot Removal Device

HELICAL OPEN-SIDE STRUCTURE

HIGHER ACUTE RECANALIZATION RATE

The Thrombite™ Mechanical Clot RetrievalDevice, featuring S-shaped helical open-side structure, is designed for more efficient clot removal and optimum revascularization in a wide range of vessels.

PRODUCT FEATURES

HELICAL OPEN-SIDE STRUCTURE

enables Thrombite™ retriever to efficiently entwine and clamp the clot

assures clot retention for confident removal and revascularization

OVERLAPPED STENT AT THE HELICAL OPEN-SIDE STRUCTURE

increases contact surface with thrombus and maximizes clot integration

EXCELLENT FLEXIBILITY AND VESSEL WALL APPOSITION

optimizes clot retention during smooth navigation through the tortuous anatomies

PRODUCT FEATURES

Radiopaque markers on the distal end of the device increase device visibility

3 markers for the sizes with 3.0 and 4.0mm diameter

4 markers for the sizes with 5.0 and 6.0mm diameter

Advanced stent surface treatment process

RADIAL FORCE

High radial force is designed for clot integration at the initial stage of stent expansion

Low radial force at nominal stent diameter ensures atraumatic retrieval

RADIAL FORCE

How a Stent Retriever ProcedureIs Performed

Stent retriever procedure is generally performed in patients with the indications of acute cerebral infarction within six hours. After femoral artery puncture, the catheter is inserted after sheath puncture, and DSA is performed along the catheter to the brain to find the position of blocked vascular. Make the stent retriever reached the position and passing through the clot. Then release to capture the clot. After that, the stent retriever will be extracted along with the clot and finally leave your body.

ORDERING INFORMATION OF CLOT RETRIEVAL DEVICE

STENT RETRIEVAL DEVICE STRUCTURE

Thrombite™

Product code

Diameter D(mm)

Recommended Vessel Diameter(mm)Min. Max.

Recommende Microcatheter ID (inch)

Working Length A(mm)

Stent Length B(mm)

System Length(mm)

3MM

CRD-3-15

3

15

27

1900

CRD-3-20

3

20

32

1900

CRD-3-25

3

25

37

1900

CRD-3-30

3

30

42

1900

4MM

CRD-4-15

4

15

27

1900

CRD-4-20

4

20

32

1900

CRD-4-25

4

25

37

1900

CRD-4-30

4

30

42

1900

5MM

CRD-5-15

5

15

27

1900

CRD-5-20

5

20

32

1900

CRD-5-25

5

25

37

1900

CRD-5-30

5

30

42

1900

6MM

CRD-6-15

6

15

27

1900

CRD-6-20

6

20

32

1900

CRD-6-25

6

25

37

1900

CRD-6-30

6

30

42

1900

INDICATIONS

Thrombite™ Clot Retriever Device

The Thrombite™ endovascular clot retrieval devicesis intended to restore blood flow by removing thrombus from a large intracranial vessel in patients experiencing ischemic stroke symptom onset.

Recently, the Billboard of the "Top 50 Most Valuable Investment Companies in China" in 2019 have been unveiled. As the first domestic company with an investment dimension, Venture50 has accompanied China's equity investment market for fourteen years. It is the authoritative reference standard for judging the investment of high-growth companies in the industry, and it is a weathervane that reflects the annual growth potential of the company. Relying on the technological innovation strength and prospects of peripheral intervention and neuro-intervention, Zylox-TonBridge Medical has stood out from more than 7,000 companies, and together with the "Internet celebrities" such as Quick, Zhihu, Himalayan, and Hi Tea, ranked among the "China's most "Top 50 Investment Companies".



在线联系供应商

至: ZYLOX-TONBRIDGE MEDICAL TECHNOLOGY CO., LTD.
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Peripheral Drug-eluting Stent System
Peripheral Drug-eluting Stent System OVERVIEW Peripheral Drug-eluting Stent System ZENFLEX® Pro Peripheral Drug-eluting Stent System, the 3rd peripheral drug-eluting medicated st...
Drug Coated PTA Balloon Catheter
Drug Coated PTA Balloon Catheter OVERVIEW Drug Coated PTA BalloonCatheter ENSURE EFFECTIVE DRUG DELIVERY OF A SAFE THERAPEUTIC DOSAGE The Drug-Coated PTA Balloon Catheter, a ver...
Peripheral Stent System
Peripheral Stent System OVERVIEW Peripheral Stent System The ZENFLEX® peripheral vascular disease stentsystem is designed to deliver a self-expanding stent to the il...
Aneurysm Coils
Aneurysm Coils OVERVIEW Aneurysm Coils The Ton-Bridge super soft coils are the neurovascular embolization coilsdesigned for the embolization of intracranial ane...
Peripheral Drug-eluting Stent System
Peripheral Drug-eluting Stent System OVERVIEW Peripheral Drug-eluting Stent System ZENFLEX® Pro Peripheral Drug-eluting Stent System, the 3rd peripheral drug-eluting stent in the...
供应产品

Same products

Bed Alarm Sensor Pad
Bed Alarm Sensor Pad 卖方: ValueApex (Shanghai) Information Technology Co., Ltd. If you're in search of a reliable and cost-effective solution for your wholesale caregiving needs...
Custom Medical Needle
Custom Medical Needle 卖方: Shanghai Kohope Medical Devices Co., Ltd. Kohope, as a custom needle manufacturer, has an independent research and development team. For ne...
Vet Equipment
Vet Equipment 卖方: APK Technology Co., Ltd. Parameter of A70 Vet Products APK Part Number A70 Brand Name APK ...
Rotatable Sphincterotome
Rotatable Sphincterotome 卖方: Leo Medical Co.,Ltd. A rotatable sphincterotome is a variation of the traditional sphincterotome used in endoscopic pr...
Pulmonology Products
Pulmonology Products 卖方: Leo Medical Co.,Ltd. LeoMedPulmonology equipmentcover pulmonology guide wire, pulmonology dilatation balloon, airway r...