Fiber Blend Ratio Tester
Whats/App: +86 156 1874 6768
Web: standard-groups.com
The Fiber Blend Ratio Tester is designed to measure the electrical resistance of a compacted fiber sample and convert it into the specific resistance of the fiber according to its filling density. It provides accurate, repeatable measurements for fiber quality evaluation, research, and production control, suitable for textile, nonwoven, and fiber material laboratories.
Application
(1) Testing specific resistance of synthetic staple fibers such as polyester, rayon, acrylic, and nylon in textile manufacturing.
(2) Quality control and R&D of fiber blends in nonwoven fabrics, yarns, and felts.
(3) Evaluation of cotton, wool, and blended natural fibers for electrical properties.
(4) Measurement of resistance in technical textiles used in automotive, aerospace, and medical applications.
(5) Assessment of fiber-based materials for smart textiles, conductive fibers, and anti-static fabrics.
(6) Comparative analysis of recycled fibers or fiber mixtures for product development.
Standards
(1) GB/T 14342-1993: Synthetic short fiber specific resistance test method.
(2) GB/T 14342-2015: Updated national standard for specific resistance measurement of man-made staple fibers.
(3) ISO 2060: Determination of the fineness of fibers by electrical resistivity (analogous methodology).
(4) ASTM D4496: Standard test method for electrical resistance of textile fibers.
(5) EN 1149-1: Protective clothing—Electrostatic properties—Test method for surface resistivity of fibers and textiles.
(6) JIS L 1020: Test method for electrical resistance of textile fibers.
Features
(1) Standard Compliance: Fully adheres to GB/T 14342 and other international standards.
(2) Wide Measurement Range: Measures fiber specific resistance from 10^6Ω to 10^13Ω.
(3) Accurate Voltage Application: Provides stable 50V and 100V test voltages with less than 5% deviation.
(4) Stable Operation: Reliable in controlled temperature (20℃±2℃) and humidity (65%±10%RH).
(5) Low Zero Drift: Less than 4% over 1–8 hours under stable voltage with no signal input.
(6) High Basic Accuracy: Basic error ≤±20% relative to standard resistance measurements.
(7) Compact Design: Laboratory-friendly size (450×265×133 mm).
(8) Indirect Measurement: Converts measured bulk resistance of compacted fiber into specific resistance.
(9) Resistance Measurement System and Fiber Compaction Chamber: Ensures precise measurement.
Parameters
| Parameter | Specification |
|---|---|
| Fiber specific resistance range | 10^6Ω – 10^13Ω |
| Test sample weight | 15 g |
| Measurement voltage | 50V, 100V, deviation <5% |
| Working temperature | 20℃ ±2℃ |
| Working humidity | 65% ±10% RH |
| Zero drift | <4% over 1–8 hours |
| Basic measurement error | ≤±20% |
| Power supply | AC 220V |
| Overall size | 450 × 265 × 133 mm (L×W×H) |
Accessories
(1) Main unit
(2) Fiber compaction chamber
(3) Sample holder
(4) Power cable
(5) User manual
Test Procedures
(1) Prepare the tester and connect the power supply.
(2) Weigh 15 g of fiber sample and place it in the compaction chamber.
(3) Set the desired measurement voltage (50V or 100V) and ensure the environment meets the temperature and humidity requirements.
(4) Start the test; the instrument compacts the fiber and measures its resistance.
(5) The tester automatically calculates the specific resistance of the fiber.
(6) Record the displayed specific resistance values for analysis.
(7) Remove the sample and clean the compaction chamber after testing.
Maintenance Information
(1) Keep the compaction chamber clean to avoid residue affecting measurements.
(2) Check electrical connections regularly and ensure stable voltage supply.
(3) Calibrate periodically using standard resistors.
(4) Avoid exposure to moisture, dust, or corrosive substances.
(5) Store the instrument in a dry, controlled laboratory environment.
(6) Monitor zero drift periodically to maintain measurement reliability.
在线联系供应商
Other supplier products
| Intramedullary Nails Internal-fixation Pull-out Force Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ASTM F543: Standard specification for metallic medical bone screws (dynamic loadi... | |
| High reliability walk-in heat aging chamber | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Walk-in High-Temperature Aging Chambers are typically assembled on-site using... | |
| ASTM E662 smoke density tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The instrument conforms to the following national and international standards: ... | |
| Scratch tester STD-KK01 | Whats/App: +86 156 1874 6768 Web: standard-groups.com Product introduction: With the continuous expansion of the use of plastic molding products... | |
| Large-Scale Composite Salt Spray Test Chamber,Drive-in Corrosion Test Rooms | Whats/App: +86 156 1874 6768 Web: standard-groups.com TheLarge-Scale Composite Salt Spray Test Chamberis a professional environmental simulation ... |
Same products
| PH-2398 pH/EC/ORP/温度 多参数测试仪 | 卖方: 科立龙电子股份有限公司 | 大显示,可同时进行水质PH、氧化还原电位、电导率、温度的测量; 带背光LCD显示清晰,功能齐全,精度高; 仪表采用微电脑测量与控制技术,具有自动校准功能,方便实用。 内置蓝牙,可以与电脑或... | |
| ORP-2026S 防水型 土壤ORP&温度 二合一测试仪 | 卖方: 科立龙电子股份有限公司 | 范围 ORP -999~999mV Temp 0~50℃ 分辨率 ORP 1mV... | |
| 防水型 EC /TDS/温度三合一参数测试仪 | 卖方: 科立龙电子股份有限公司 | 范围 EC ~19.9mS TDS Temp 0~50℃ 分辨率 ... | |
| EC-98330 电导率营养测试棒 | 卖方: 科立龙电子股份有限公司 | 本营养测试仪适用于水培和农业应用,能够准确测量水中的营养液电导率(EC)单位为mS/cm,以及总溶解固体(TDS)转换为百万分之一(ppm)。 适合需要较高EC值的植物,该测试仪具有高达6.0... | |
| PH-808防水笔式土壤PH计 | 卖方: 科立龙电子股份有限公司 | 两点按键校准,自动识别pH标准缓冲液 自动温度补偿确保全量程范围的精确测量。 自动电源关闭,有效节省电池能耗。 可替换型电极降低仪表维护与使用成 全防水性能保障在恶劣环境中对仪表的完整保... |