No baffle-board ultrasonic heat meter
- Structure
·Flowsensor:straightthroughtypeinwallreflectionultrasonicflowsensorwithnoreflectionplatestandandbeampieces
·Temperaturesensor:PT1000temperaturesensorpair
·Opticalinterface,M-businterfacefordatacommunication
- Flow
- Ratedflow:1.5~3.5m³/h
- Ratedflowandminflowproportionis100.
- Temperatureandtemperaturedifference
- Temperaturemeasurementrange:4~95℃
- Temperaturedifference:3~90℃
- Thermalcoefficient:Alongwithinletandoutletwater
- Connectionmode
- Installationposition:inletoroutletasinstructed(optional)
- Connectiontype:threadedconnection
- Maxworkingpressure:1.6MPa
- Servicecondition
- Environmentcondition:ClassA
- Display
- Display:LCD,8digits,specialsymbols
- Dimension:kWh,MJ
- Resolution
(1)Heat:1kWhor1MJ
(2)Cumulativeflow:0.01m³
(3)Temperature:0.1℃
(4)Temperaturedifference:0.1K
- Datastorage
- Datastorage:ROM
- Storeatleast18months’data
- Intensityandtightness
- Nodamageandleakagewhenthemediumtemperatureis10℃lessthanthemaxworkingtemperatureandthepressureis1.6timesgreaterthanthemaxworkingpressure.
- Accuracy
- MeteringaccuracyisClass2
- Pressureloss
- Pressureloss<10kPa(Industrialstandard:Maxallowedpressurelossis25kPa)
- Powersupply
- Built-inlithiumbattery(3.6VDC/3.8Ah),externalremotedataacquisitionsystempowersupplyispossible
- Batterylife:≥10years(Industrialstandard:built-inbatterylife>5+1years)
- Workingcurrent:10~40μA
- Safetyrequirements
- Whenthepowersupplyisstoped,therecorddataofheat,cumulativeflowandcorrespondingtimebeforepoweroff.Canreformnormalmeteringafterpowerisrestored
- Themeteringcharacterswillnotbeaffectedwhenthemagneticinterferencestrengthisnotgreaterthan100KA/m
- TheenclosureprotectiongradeisIP54
- Accordingtorelevantnationalstandard,intheenvironmentconditionofdryheat,cooling,steadydamp-heat,cyclicdamp-heatandcryogenicstorage,whentheanalogparametersareinput,theheatmetercanworknormally.
- Accordingtorelevantnationalstandard,intheenvironmentconditionofline-voltagevariation,electricalfasttransient,electromagneticfield,electricsurge,powerfrequencymagneticfieldandelectrostaticdischarge,theheatmetercanworknormally.
在线联系供应商
Other supplier products
震宇超传导热能管 | 超传导体输送热能管供暖,可利用公用供暖管网、户用电加热器、燃气炉、太阳能作为热源,循环水用量仅为传统地暖管的1/8,节能效果比传统散热设备提高70%以上。 超传导散热产品,使用少量循环水即可快速达到供暖效果,循环水管路几乎没有热量损失,可最大限度利用热能,其综合节能效果十分明显。 国内常用... | |
large diameter stainless steel ultrasonic heat meter | Large diameter DN50-200, stainless steel. Features: Squareholestraightthroughbasemeter---noblockage,lowpressureloss. Usingthepipewallreflection---... | |
No baffle-board ultrasonic heat meter | “ZY-DN20,ZY-DN25noreflectionplateultrasonicheatmeter”techniquecharacters (1)Theflowsensorisnoreflectionstructureusingmeasurementpipei... | |
Ultrasonic heat meter | ZY-C ultrasonic heat meter consists of flow meter, temperature meter and calculator and is simple to install, read and verify. It is ideal for meas... | |
ultrasonic heat energy meter | “ZY-DN20, ZY-DN25 no reflection plate ultrasonic heat meter” technique characters (1) The flow sensor is no reflection structure using measurement ... |
Same products
Walk In Environmental Chamber | 卖方: Guangdong ALI Testing Equipment Co,.Ltd | Application JOEO Multi-functional walk in environmental chamber is the perfect testing place for ... | |
Solid Walk In Test Chamber | 卖方: Guangdong ALI Testing Equipment Co,.Ltd | Application: JOEO solid walk in test chamber is an all-welded test chamber with an integrated con... | |
Compact Walk In Environmental Chamber | 卖方: Guangdong ALI Testing Equipment Co,.Ltd | Application JOEO compact walk in environmental chamber is used to test full-size solar panels or ... | |
Drying Walk In Environmental Chamber | 卖方: Guangdong ALI Testing Equipment Co,.Ltd | Application Dry walk in environmental chambers are a special type of walk in environmental chambe... | |
Walk In Test Chamber For CATL Battery | 卖方: Guangdong ALI Testing Equipment Co,.Ltd | CATL Battery Walk In Test Chamber JOEO Walk In Test Chamber's temperature cyclic stress screening... |