No baffle-board ultrasonic heat meter
- “ZY-DN20,ZY-DN25noreflectionplateultrasonicheatmeter”techniquecharacters
(1)Theflowsensorisnoreflectionstructureusingmeasurementpipeinwallrefection
(2)Theflowmetersensorpipewithoutreflectionplatesupportandbeampiecesistotallystraightthrough,noblocking,nowear.
(3)Theflowmetersensorpipewithoutanyinternalpartwhichremovestheobstructionstowaterflowcausedbythereflectionplate,reflectionplatesupportandbeampiecesoftraditionalbasemeter,lowpressureloss,reducespressurelossoftheheatingdistributionsystem.
(4)Adoptingdualpowersupplytechnologyofbuilt-inbatteryandexternalremotecommunicationsystempowersupplyreducestheremotecommunicationeffectsonbuilt-inbatterylife.
(5)Boththeflowsensorpipeinwallandthetransducersurfaceadoptmetalchemicalanti-foulingdesignanddisposetoensuretheultrasonicsignalintensity.
(6)Featuresemptypipedetection(entersintodormantstateoutofheatingperiod)andautomaticwake-upfunction.
(7)TheprocessorusesMSP430dedicatedchipofAmericanTIcompany,ultra-lowpowerconsumption,modularfunction,lessperipheralcircuit.
(8)TheultrasonicsensordedicateddetectionchipadoptsTDC-GP2/GP21ofGermanyACAMcompany,withhighprecisionmeteringaccuracy.
(9)Adoptingintegratedlowpowerconsumptioncircuitdesignprolongsthebatteryworkinglifewiththeoreticworkinglifeover10years.
(10)ThehighprecisionPT1000platinumresistancepairtemperaturesensoradoptingGermanytemperature-sensingelementandKoreaproductiontechnologysatisfiesthemeteringaccuracyrequirements.
- “ZY-DN20,ZY-DN25noreflectionplateultrasonicheatmeter”maintechniqueparameters
- Structure
·Flowsensor:straightthroughtypeinwallreflectionultrasonicflowsensorwithnoreflectionplatestandandbeampieces
·Temperaturesensor:PT1000temperaturesensorpair
·Opticalinterface,M-businterfacefordatacommunication
- Flow
- Ratedflow:1.5~3.5m³/h
- Ratedflowandminflowproportionis100.
- Temperatureandtemperaturedifference
- Temperaturemeasurementrange:4~95℃
- Temperaturedifference:3~90℃
- Thermalcoefficient:Alongwithinletandoutletwater
- Connectionmode
- Installationposition:inletoroutletasinstructed(optional)
- Connectiontype:threadedconnection
- Maxworkingpressure:1.6MPa
- Servicecondition
- Environmentcondition:ClassA
- Display
- Display:LCD,8digits,specialsymbols
- Dimension:kWh,MJ
- Resolution
(1)Heat:1kWhor1MJ
(2)Cumulativeflow:0.01m³
(3)Temperature:0.1℃
(4)Temperaturedifference:0.1K
- Datastorage
- Datastorage:ROM
- Storeatleast18months’data
- Intensityandtightness
- Nodamageandleakagewhenthemediumtemperatureis10℃lessthanthemaxworkingtemperatureandthepressureis1.6timesgreaterthanthemaxworkingpressure.
- Accuracy
- MeteringaccuracyisClass2
- Pressureloss
- Pressureloss<10kPa(Industrialstandard:Maxallowedpressurelossis25kPa)
- Powersupply
- Built-inlithiumbattery(3.6VDC/3.8Ah),externalremotedataacquisitionsystempowersupplyispossible
- Batterylife:≥10years(Industrialstandard:built-inbatterylife>5+1years)
- Workingcurrent:10~40μA
- Safetyrequirements
- Whenthepowersupplyisstoped,therecorddataofheat,cumulativeflowandcorrespondingtimebeforepoweroff.Canreformnormalmeteringafterpowerisrestored
- Themeteringcharacterswillnotbeaffectedwhenthemagneticinterferencestrengthisnotgreaterthan100KA/m
- TheenclosureprotectiongradeisIP54
- Accordingtorelevantnationalstandard,intheenvironmentconditionofdryheat,cooling,steadydamp-heat,cyclicdamp-heatandcryogenicstorage,whentheanalogparametersareinput,theheatmetercanworknormally.
- Accordingtorelevantnationalstandard,intheenvironmentconditionofline-voltagevariation,electricalfasttransient,electromagneticfield,electricsurge,powerfrequencymagneticfieldandelectrostaticdischarge,theheatmetercanworknormally.
在线联系供应商
Other supplier products
| ultrasonic heat meter with no reflection plate | Features: Squareholestraightthroughbasemeter---noblockage,lowpressureloss. Usingthepipewallreflection---stablesignal,lowfailures. Extendedtransduc... | |
| ultrasonic heat energy meter | ZYultrasonicheatmeterconsistsofflowsensor,temperaturesensorandcalculatorandissimpletoinstall,readandverify.Itisidealforthemeasurementofenergyconsum... | |
| Superconducting radiator | Superconductingheattransferisanenergy-savingadvancedtechnologywhichwasfirstlyinventedandappliedinmannedspaceflightbyAmericaaerospaceengineeringandt... | |
| 震宇超传导热能管 | 超传导体输送热能管供暖,可利用公用供暖管网、户用电加热器、燃气炉、太阳能作为热源,循环水用量仅为传统地暖管的1/8,节能效果比传统散热设备提高70%以上。 超传导散热产品,使用少量循环水即可快速达到供暖效果,循环水管路几乎没有热量损失,可最大限度利用热能,其综合节能效果十分明显。 国内常用... |
Same products
| Reliable Components for Water and Industrial Systems | 卖方: 866507 | The Stainless Steel Float Ball is designed for automatic liquid level control and fluid managem... | |
| Double Convex Lenses | 卖方: Shandong Yanggu Constant Crystal Optics, Inc | Double Convex Lensesare used in image relay applications, or for imaging objects at close conjuga... | |
| Wedge Prism | 卖方: Shandong Yanggu Constant Crystal Optics, Inc | Wedge prismis an optical element with plane-inclined surfaces, usually the faces are inclined tow... | |
| Ball Lenses | 卖方: Shandong Yanggu Constant Crystal Optics, Inc | Ball Lensesare commonly used to improve signal quality in fiber coupling applications, or for use... | |
| KAZUKI 6-GFM-33 12V33Ah AGM Gel Battery | 卖方: Xin Tang Shallow Power Supply Co.,LTD | KAZUKI 6-GFM-33 12V33Ah AGM Gel Battery Small Office & Retail UPS Backup Power Systems... |