Pre-filled Syringe Push Force Meter
The Push - force Tester for Prefilled Syringes is widely used in the medical device industry, mainly for testing the push - force performance of prefilled syringes during the injection process. The following is a detailed introduction to its main uses, compliance standards, and technical parameters:
Standards
YY/T 0962 - 2021 Determination of Push - force for Prefilled Syringes, etc.
Main Uses
- Quality Control and Supervision The push - force tester for prefilled syringes is an important tool for medical device manufacturers to conduct product quality control and supervision. Through testing, it can be ensured that the produced prefilled syringes comply with relevant national standards and regulations, thus improving product quality and safety. - Performance Evaluation and Optimization This tester can be used to evaluate the push - force performance of prefilled syringes of different models and specifications, including parameters such as maximum push - force, minimum push - force, and average push - force. Through the analysis and comparison of test data, it can provide strong support for product performance optimization. - R & D Support During the R & D process of prefilled syringes, the tester can be used to test the R & D effects and performance improvement of new products. The feedback of test data can help R & D personnel promptly identify problems and make improvements, thereby accelerating the product R & D progress and enhancing product quality. - Fault Diagnosis and Repair For prefilled syringes with malfunctions, the tester can be used to identify fault points and determine repair solutions. Through the analysis of test data, the causes of faults can be found, and corresponding repair measures can be taken to ensure the normal operation of the equipment.
Technical Parameters
- Force Measuring Range: 0 - 50N (customizable according to actual needs), used to measure the magnitude of the push - force during the injection process of prefilled syringes.
- Force Accuracy: Level 0.5 (error ±0.5%), ensuring the accuracy and reliability of test results. - Time Setting: Freely set within 0 - 9999 seconds, and the test time can be flexibly adjusted according to test requirements. - Test Speed: 0.05 - 500mm/min (or customizable according to actual needs), used to control the speed during the injection process to simulate actual usage scenarios. - Speed Accuracy: Level 1 (error ±1%), ensuring the stability and accuracy of the test speed. - Nominal Capacity: 0 - 100mL (or customizable according to actual needs), suitable for testing prefilled syringes of different capacities. - External Dimensions: For example, 300mm×300mm×500mm (the specific dimensions vary depending on the model), facilitating placement and operation. - Weight: Moderate, easy to carry and move. - Power Supply: Usually 220V, 50Hz (customizable according to local electrical standards), ensuring the normal operation of the tester. - Standard Configuration: Includes the main unit, a miniature printer, a touch screen, test fixtures, etc., meeting test requirements and providing a convenient operation interface and data recording functions.
在线联系供应商
Other supplier products
| Bone Screw Pull-out Tester | Standard YY/T 1504, ASTM F543: standard specifies a test method for measuring the axial force required to extract or fail a metallic bone screw f... | |
| G234 Bed Blanket Flammability Tester | The test instrument is used to detect the flame resistance of the blanket fabric and the flame spread performance of the fabric surface. The test m... | |
| Minimum Ignition Energy Dust Cloud Tester | Description: Dust Cloud Minimum Ignition Energy Tester disperses a certain mass of dust specimen to be tested into the Hartmann tube device throug... | |
| fogging test equipment | Working Principle: The main frame of theFogging Testerincludes a water sink fully filled with specified ethylene glycol, which can reach a high te... | |
| Fabric ici pilling and snagging box | Standard GB/T 4802.3: China’s national standard for textile pilling resistance. BS EN ISO 12945-1: European standard for wool-based texti... |
Same products
| FH-77富氢测试笔 | 卖方: 科立龙电子股份有限公司 | 产品说明: 用于测量氢气水(富氢水)和氢气水发生器的溶解氢含量。 特征: 1、电极更换方便 智能、携带方便、操作方便、实用; 产品广泛应用于食品、环卫、地质勘探、冶金、地表水、 ... | |
| Xenon Arc Weather Ometer | 卖方: Standard Group (Hong Kong) Limited | Get a quote: Whats/App: +86 181 0160 0864 SI4000Xenon Arc Weather Ometer utilizes a xenon lamp ... | |
| Xenotest | Light Fastness Tester Si220 (SunTest) | 卖方: Standard Group (Hong Kong) Limited | Get a quote: Whats/App:+86 180 0160 0864 A Light Fastness Tester, or Xenon Tester, Accelerated ... | |
| Ozone Aging Chamber | 卖方: Standard Group (Hong Kong) Limited | Get a quote: Whats/App:+86 156 1874 6768 The Ozone Aging Chamber is a precision testing instrum... | |
| Plastic Smoke Density Tester F313 | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com The F313 Plastic Smoke Density Tester is ... |