SO2 H2S HCL Corrosion Test Equipment

Meeting Standards:

Carry out various sulfur dioxide gas corrosion tests in accordance with GB10587 - 89. GB2423.9 - 93. GJB150. QC/T417.1 - 2001 and equivalent standards such as IEC, DIN, MIL, ASTM.

IEC 60068-2-42

Environmental Requirements:

1. Power supply: AC380V 3Φ 10KVA 0HZ 2. Allowable voltage range: ±5% of the rated value 3. Maximum load: 6KVA 4. The distance between the chamber and the wall should be greater than 600cm.

Description:

Stainless Steel Noxious Gas Corrosion SO2 H2S CO2 HCL Artificial Climate Chamber:

SO2 HCL H2S Noxious Gas Corrosion Environmental Test Chamber reproduce damages by temperature, relative humidity and noxious gas Corrosion to material, components and constructions.

SO2 HCL H2S Noxious Gas Corrosion Environmental Test Chamber can be used to test t SO2, H2S.

SO2 HCL H2S Noxious Gas Corrosion Environmental Test Chamber can be used for single gas tests.

SO2 HCL H2S Noxious Gas Corrosion Environmental Test Chamber are ranging in size from 100Ltier to 1000Liter.

Structural Materials and Features:

1. The chamber is molded from epoxy fiberglass. Asbestos board is pasted inside the jacket. It is resistant to high temperature and corrosion, lightweight, and has high strength. Both the inner and outer walls of the chamber are smooth and easy to clean.

2. The chamber cover is made of epoxy fiberglass with a top cover temperature of 100 - 200°C to prevent condensed water in the chamber from dripping directly onto the test specimens.

3. Heater: The nickel - chromium alloy heating wire heats from the bottom, forming jacket heating to ensure good temperature uniformity inside the chamber.

4. Humidification method: Humidification by a steam generator.

5. Input methods for sulfur dioxide and hydrogen sulfide: Input from cylinders, and both input and discharge are quantitatively controlled by concentration sensors.

6. Exhaust gas treatment: Install treatment devices for sulfur dioxide and hydrogen sulfide gases. After multi - stage treatment with sodium bicarbonate, the exhaust gas meets the discharge standards (the purification device is external).

Control System:

1. Temperature control: Japanese Fuji temperature controller

2. Temperature input: PT100; Output: Driven by SSR

3. Display range: 0 - 100°C

4. Control range: RT + 5 - 55°C

5. Cycle used (measurement filtering): 2 - 3s

6. The main control components are products from joint - venture companies.

7. The temperature is controlled by a solid - state relay, with stable performance and no noise.

8. A fan is used for stirring and circulation inside the chamber.

9. Display and control of sulfur dioxide concentration

Technical Parameters:

1. Temperature range: 10 - 55°C

2. Temperature fluctuation: ±0.5°C

3. Temperature uniformity: ±2°C

4. Sulfur dioxide gas concentration: 100ppb - 50000ppb (0.1ppm - 50ppm)

5. Hydrogen sulfide gas concentration: 10ppb - 5000ppb (0.01ppm - 5ppm)

6. Relative humidity: 75±3%

7. Tests with sulfur dioxide, hydrogen sulfide, and mixed gases of sulfur dioxide and hydrogen sulfide can be conducted.


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

50-125L automatic drum cleaning equipment, 11 to 28 gallon barrel washer
50-125L automatic drum cleaning equipment, 11 to 28 gallon barrel washer 0-125L automatic drum cleaning equipment, 11 to 28 gallon barrel washer Design features: This complete barrel washer utilizes our rotary impingem...
Xenon Arc Weatherometer
Xenon Arc Weatherometer IntroductionThe xenon arc lamp, which is capable of simulating the whole natural sunlight spectrum in the most consistent manner, can reproduce t...
Pipe drop hammer impact testing machine
Pipe drop hammer impact testing machine Product Introduction: 1. Name: drop hammer impact testing machine 2. Model :G-1 3. Product introduction: Automatic series drop hammer impact tes...
Vertical Flammability Tester
Vertical Flammability Tester IntroductionVertical Flammability Chamber for measuring the vertical flame spread for children’ sleepwear, fabrics, other textile materials o...
 Fabric ici pilling and snagging box-QINSUN
Fabric ici pilling and snagging box-QINSUN Standard GB/T 4802.3: China’s national standard for textile pilling resistance. BS EN ISO 12945-1: European standard for wool-based textile...
供应产品

Same products

Seat Bumping and Creep Test Bench
Seat Bumping and Creep Test Bench 卖方: Standard International Group (HK) Limited This test bench is used for simulating the car seat bumping and creep situation when a car is run...
Automobile seat belt fixed point test bench
Automobile seat belt fixed point test bench 卖方: Standard International Group (HK) Limited Applicable standards: National mandatory standards: GB 15083-2006"Automobile seats, seat fixtur...
Impact strength tester for car seat headrest
Impact strength tester for car seat headrest 卖方: Standard International Group (HK) Limited Applicable standards: GB 15083-2006 "Automobile seats, seat fixtures and headrest strength requi...
Impact strength tester for car seat launching headrest
Impact strength tester for car seat launching headrest 卖方: Standard International Group (HK) Limited Main parameters: Impact speed:The impact speed of the tester is usually between 25 and 30km/h, w...
Automobile Headrest Strength Tester
Automobile Headrest Strength Tester 卖方: Standard International Group (HK) Limited Applicable standards: GB 11550-2009"Automobile seat headrest strength requirements and test me...