.

HIV (1/O/2) Tri-line Antibody Rapid Test

The ADVIA Centaur HIV 1/O/2 Enhanced assay is an antigen bridging microparticle chemiluminometric immunoassay used for the detection of antibodies to the human immunodeficiency virus type 1, including Group O, and/or type 2 in serum or plasma.

The ADVIA Centaur HIV 1/O/2 Enhanced assay uses yeast recombinant derived antigens corresponding to the viral envelope and core proteins. Recombinant antigens include an HIV-1 envelope protein (gp41/120), an HIV-1 core protein (p24), and an HIV-2 envelope protein (gp36). A synthetic peptide is added for the detection of antibodies to HIV-1 group O.

The primary purpose of the ADVIA Centaur HIV 1/O/2 Enhanced essay is to aid in the diagnosis of HIV infection and AIDS. Specimens that are initially reactive should be retested in duplicate. Repeat reactivity is highly predictive of the presence of antibodies to HIV-1 and/or HIV-2 in specimens from people at risk for HIV infection and should be followed up with appropriate supplemental tests for HIV-1 and HIV-2 antibodies before making a diagnosis of HIV infection.



Product Description of HIV (1/O/2) Tri-line Antibody hiv test kit wholesale

This panel consists of six members, manufactured from human serum or plasma, with a range of concentrations of HIV antibodies and p24 antigen. Panel members were filtered through a 0.2 micron filter. ProClin® (0.1%) was added as a preservative.

The human immunodeficiency virus is the causative agent of acquired immunodeficiency syndrome (AIDS). AIDS was first described in the United States in 1981 and has become one of the leading causes of death worldwide. Despite educational efforts directed towards reducing the transmission of AIDS and increased advancements in treatment, the number of AIDS cases continue to increase. By the year 2010, it is estimated that there will be at least 45 million new human immunodeficiency virus (HIV) infections worldwide.

Human immunodeficiency virus type 1 (HIV-1) has been identified as the primary cause of acquired immunodeficiency syndrome (AIDS). This retrovirus, a member of the lentiviral

subfamily, is spread by sexual contact, exposure to infected blood or blood products, and perinatal transmission. In 1986 human immunodeficiency virus type 2 (HIV-2) was isolated

from AIDS patients in West Africa. These viruses share epitopes of the core proteins, but exhibit little or no cross-reactivity between the envelope glycoproteins.

Comparison of the nucleic acid sequences for HIV-1 and HIV-2 shows approximately 60% homology in the conserved genes, such as gag and pol (encoding core proteins), and 30 to40% homology in less conserved regions (encoding envelope proteins). HIV-1 has been subdivided into group M (subtypes A-H) and Group O.5 The routes of transmission of HIV-1 and HIV-2 are the same, however, in HIV-2 infections the transmission and the viral replication rate are much lower. Clinical studies have shown that in HIV-2 infections there is a slower disease progression than in HIV-1 infections. In HIV-2 infections there is a slower rate in the decline of CD4 T cells and reduced viremia. Individuals infected with HIV-2 generally have a better clinical outcome.

Come and get hiv rapid kit price.

Intended Use of HIV (1/O/2) Tri-line Antibody Rapid Test

HIV 1/2/O/p24 Qualification Panel QRX701 is a panel of six members with established reactivity in anti-HIV-1, anti-HIV-2, anti-HIV-1 group O, HIVp24 antigen and combination assays. This panel may be used for training, qualifying, and re-qualifying technical personnel in the performance of tests for the detection of HIV. The panel may also be used as part of ongoing programs for lot acceptance and internal proficiency testing for HIV assays, to isolate system errors, in troubleshooting these assays, and as a component of a quality assurance program. For Research Use Only. Not for use in diagnostic procedures.

Testing Principles of HIV (1/O/2) Tri-line Antibody Rapid Test

HIV 1/2 utilizes the principle of immunochromatography, a unique two site immunoassay on a membrane. In HIV 1/2, a mixture of highly purified recombinant antigen of gp 41, recombinant p24 combined to subtype O specific synthetic peptide, representing HIV-1 and recombinant gp 36 representing HIV-2 are coated on the membrane in the test region and anti-rabbit antiserum in the control region. As the test sample flows through the membrane assembly within the test device, the colored - HIV 1/2 specific recombinant antigen-colloidal gold conjugate complexes with HIV antibodies in the sample. This complex moves further on the membrane to the test region where it is immobilized by the HIV 1/2 Specific recombinant antigens coated on the membrane leading to formation of the colored band which confirms a positive test results. Absence of this colored band in the test region indicates a negative test result. The unreacted conjugate and unbound complex if any along with rabbit IgG colloidal gold conjugate move further on the membrane and are subsequently immobilized by the anti-rabbit antibodies coated on the membrane at the control region, forming a colored band. This control band serves to validate the test results.

Or you may be interested in myo testand in vitro diagnostic reagents.



Send product request

To: Hanzghou Frenovo Biotech Co.,Ltd.
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Carcinoembryonic Antigen (CEA) Rapid Test
Carcinoembryonic Antigen (CEA) Rapid Test Carcinoembryonic antigen (CEA) has been shown to be associated with tumor burden in patients with colorectal cancer. However, it is also elevated t...
Goat Anti Mouse IgG
Goat Anti Mouse IgG This antibody is a high-quality secondary antibody, which is immunized with purified goat mouse IgG and purified by affinity column and adsorbed by...
Strep A Antigen Rapid Test
Strep A Antigen Rapid Test Instant strep testutilizes two-site sandwich immunoassay technology for the detection of Group A Streptococcal antigen. The test consists of a memb...
Rotavirus Antigen Rapid Test
Rotavirus Antigen Rapid Test Rotavirus Test Kt Device (Feces) is a rapid visual immunoassay for the qualitative, presumptive detection of rotavirus in human fecal specimens. Th...
Mouse Anti Human IgM
Mouse Anti Human IgM Mouse Anti Human IgMis often applied in EIA, LF, Fluorescent, and it is recommend to use for coating. Specification ofMouse Anti Human IgM ...
All supplier products

Same products

Marine Clear View Screen
Marine Clear View Screen Seller: Zhenjiang matchau marine equipment co.,ltd. Marine Clear View Screen WS-300CR and WS-350CR Marine Clear View Screenare primarily composed of...
LCD Monitor Screen SAD2701KH
LCD Monitor Screen SAD2701KH Seller: Kerchan Technology Co., Ltd LCD Monitor Screen SAD2701KH Frameless Housing. Screen definition: 1920*1080. Support 1080...
Tiger Series Indoor Rental LED Screen
Tiger Series Indoor Rental LED Screen Seller: Ledtop Visual Ltd. As one of the leading indoor led screen rental manufacturers, Ledtop focuses on producing screens...
LED Screen Rental
LED Screen Rental Seller: Ledtop Visual Ltd. As a Chinese rental LED display factory/supplier, we offer Chinese-style product names such as Dr...
Dragon Series Outdoor And Indoor LED Screen For Rent
Dragon Series Outdoor And Indoor LED Screen For Rent Seller: Ledtop Visual Ltd. Outdoor and indoor Large LED screens for hire are primarily used in stage performances, art shows...