German Standard Industrial Cables NYCY

German Standard Industrial Cables NYCYApplication and DescriptionNYCY cables are used in power plants,Website:, industrial and switching installations, for street lighting, domestic power supply connections, in secondary distribution networks and other. These cables are preferentially used for underground application as well as for interior installation in room and cable ducts and for outdoor and applications, for indoor installations, in the open air, underground and in water where greater mechanicalStandard and ApprovalVDE0276 part 603, CENELEC HD603 S1, IEC 605027 cores and above to VDE0276 part 627, CENELEC HD627 S1, IEC 60502Cable Construction- Solid plain copper conductor- to DIN VDE 0295 cl. 1 and IEC 60228 cl. 1- PVC insulation DIV4 to HD 603.1- Color coded to DIN VDE 0293-308, 0276 part 603 or HD 186- PVC filling and bedding- Concentric conductor: copper wires and helical copper tape- PVC outer jacket DMV5 to HD 603.1Technical Characteristics- Working voltage: 600/1000 volts- Test voltage: 4000 volts- Flexing bending radius: 15 x Ø- Static bending radius: 12 x Ø- Flexing temperature: -5º C to +50º C- Fixed installation temperature: - 40º C to +70º C- Short circuit temperature: +160º C- Flame retardant: IEC 60332.1- Insulation resistance: >100 MΩ x kmCable ParameterAWGNO. OF CORES XNOMINAL CROSSSECTIONAL AREA# X MM²CONDUCTORTYPENOMINALOVERALL DIAMETER MMNOMINAL COPPER WEIGHT KG/KMNOMINAL CABLE WEIGHT KG/KM81 x 10.0re/ x 16.0re/ x 1.5re/1. x 2.5re/2.513.580270122 x 4.0re/415.5123360102 x 6.0re/ x 10.0re/1019.531259062 x 16.0re/1620.5489820163 x 1.5re/1.513.566225143 x 2.5re/2.514.5104290123 x 4.0re/416.5161400103 x 6.0re/617.524051083 x 10.0re/ x 16.0re/ x 1.5re/1.514.581260144 x 2.5re/2.515.5128350124 x 4.0re/ x 6.0re/618.529759084 x 10.0re/ x 16.0re/ x 1.5re/1. x 2.5re/2. x 4.0re/ x 6.0re/ x 10.0re/ x 1.5re/1. x 1.5re/2. x 2.5re/2.517.5200450127 x 4.0re/ x 6.0re/ x 1.5re/1. x 1.5re/2. x 2.5re/2. x 1.5re/2. x 2.5re/420. x 1.5re/2. x 2.5re/ x 1.5re/2.520. x 2.5re/ x 2.5re/622. x 1.5re/ x 2.5re/ x 1.5re/ x 2.5re/623. x 1.5re/ x 2.5re/ x 1.5re/ x 2.5re/ x 1.5re/ x 2.5re/ x 1.5re/ x 2.5re/ x 1.5re/ x 2.5re/ x 1.5re/ x 2.5re/
Other supplier products
|
|
P18 RU 0.6/1kV NEK606 Water Blocked Offshore Marine Cables |
P18 RU 0.6/1kV NEK606 Water Blocked Offshore Marine Cables
Applications
TheseP18 RU 0.6/1kV NEK606 Water Blocked Offshore Marinecables are flame ... |
|
|
FL2XCYRY Airport Cable |
FL2XCYRY Airport Cable
Applications
These cables are used as airfield lighting equipment primary cables for the series circuit connecting the Const... |
|
|
[FA-] MPYS, MPYCS, MPYCYS |
250V [FA-] MPYS,Website:, MPYCS, MPYCYSStandards:JISC 3410-1999IEC 60332-1IEC 60332-3 Cat.A(for FA-type)CABLE CONSTRUCTIONConductorMTinned anneale... |
|
|
Type MP-GC Three-Conductor Mine Power Feeder Cable, PVC Jacket, 15kV ICEA S-75-381 |
Type MP-GC Three-Conductor Mine Power Feeder Cable,Website:, PVC Jacket, 5kV ICEA S-75-381ApplicationsThese cables are designed for connections be... |
|
|
FLR31Y11Y Airfield Lighting Cables |
FLR31Y11Y Airfield Lighting Cables
Applications
FLR31Y11Y are used as airfield lighting cable for secondary electrical circuits. The cable insulati... |
All supplier products
Same products