Safety Mat Safety Relay

Safety mat relaymodules provide a high level of fail-safe operation for critical processes and protection. This safety mat and multi-function controllers safety relay offer 2 or 4-wire safety mats/edges. Automatic reset and monitored manual reset are available.

The programmable safety relays support 3 safety output contacts (N/O) and 1 auxiliary output contacts (N/C) or 2NO+1NC+1SO or 2NO(t)+1NC(t).

Features & Advantages of Safety Mat Safety Relay

2-wire safety mats/edge

4-wire safety mats/edge

Automatic reset

Monitored manual reset

Parameter of Safety Mat Safety Relay

CZSR8301-3A1B

CZSR8301-3A1B(M)

CZSR8302-3A1B

CZSR8303-3A1B

Supply voltage

24V DC/AC

24V DC/AC

24V DC/AC

100V~230V AC

Voltage tolerance

-

Current consumption

≤90mA (24V DC) / ≤240mA (24V AC)

≤90mA (24V DC) / ≤240mA (24V AC)

≤90mA (24V DC) / ≤240mA (24V AC)

≤7 VA (220V AC)

Input current

≤50mA (24V DC)

≤50mA (24V DC)

≤10mA (24V DC)

≤10mA (220V AC)

Cable resistance

≤15Ω

≤15Ω

≤15Ω

≤15Ω

Input devices

Safety mats (4-wire)

Safety mats (4-wire)

Safety mats (4-wire)

Safety mats, safety edges (2 or 4-wire)

Number of contacts

3NO+1NC

3NO+1NC

3NO+1NC

Contact material

AgSnO2 + 0.2 µm Au

AgSnO2 + 0.2 µm Au

AgSnO2 + 0.2 µm Au

AgSnO2 + 0.2 µm Au

External contact fuse protection

10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC)

10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC)

10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC)

10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC)

Mechanical endurance of contacts

≥107

≥107

≥107

≥107

Utilisation category

In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V

In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V

In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V

In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V

Switch-on delay

≤300ms

≤150ms

≤300ms

≤300ms

Delay-on de-energisation

≤30ms

≤30ms

≤30ms

≤30ms

Recovery time

≤300ms

≤300ms

≤100ms

≤500ms

Supply short interruption

20ms

20ms

20ms

20ms

EMC

EN60947, EN61000-6-2, EN61000-6-4

EN60947, EN61000-6-2, EN61000-6-4

EN60947, EN61000-6-2, EN61000-6-4

EN60947, EN61000-6-2, EN61000-6-4

Vibration

Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm

Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm

Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm

Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm

Ambient temperature

-20℃~+60℃

-20℃~+60℃

-20℃~+60℃

-20℃~+60℃

Storage temperature

-40℃~+85℃

-40℃~+85℃

-40℃~+85℃

-40℃~+85℃

Relative humidity

10%~90%

10%~90%

10%~90%

10%~90%

Elevation

≤2000m

≤2000m

≤2000m

≤2000m

Overvoltage category

Pollution degree

2

2

2

2

Rated insulation voltage

250V AC

250V AC

250V AC

250V AC

Rated impulse voltage

6000V (1.2/50us)

6000V (1.2/50us)

6000V (1.2/50us)

6000V (1.2/50us)

Dielectric strength

1500V AC, 1min

1500V AC, 1min

1500V AC, 1min

1500V AC, 1min

Clearance and creepage distance

In accordance with EN 60947-1

In accordance with EN 60947-1

In accordance with EN 60947-1

In accordance with EN 60947-1

Safety integrity level

SIL3

SIL3

SIL3

SIL3

Performance level

PLe

PLe

PLe

PLe

Category

CZSR8302-2A1B1S

CZSR8302-2AT1BT1S

Supply voltage

24V DC/AC

24V DC/AC

Voltage tolerance

Current consumption

≤120mA (24V DC), ≤300mA (24V AC)

≤120mA (24V DC), ≤300mA (24V AC)

Input current

≤10mA (24V DC)

≤10mA (24V DC)

Cable resistance

≤15Ω

≤15Ω

Input devices

Safety mats, safety edges (2 or 4-wire)

Safety switches, Contact switches

Terminal resistance

Number of contacts

2NO+1NC+1SO

2NO(t)+1NC(t)

Contact material

AgSnO2 + 0.2 µm Au

AgSnO2 + 0.2 µm Au

External contact fuse protection

10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC)

10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC)

Mechanical endurance of contacts

≥107

≥107

Utilisation category

In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V

In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V

Semiconductor output data

Number of semi-output:1SODriving ability:20mA/24V DC

Number of semi-output:1SODriving ability:20mA/24V DC

Switch-on delay

≤300ms

≤300ms

Delay-on de-energisation

≤30ms(instantaneous)

≤30ms (instantaneous)0s, 0.5s, 1s, 2s, 3s, 5s(Deleted factory set as 5s)

Recovery time

≤100ms

≤100ms

Supply short interruption

20ms

20ms

EMC

EN60947, EN61000-6-2, EN61000-6-4

EN60947, EN61000-6-2, EN61000-6-4

Vibration

Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm

Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm

Ambient temperature

-20℃~+60℃

-20℃~+60℃

Storage temperature

-40℃~+85℃

-40℃~+85℃

Relative humidity

10%~90%

10%~90%

Elevation

≤2000m

≤2000m

Overvoltage category

Pollution degree

2

2

Rated insulation voltage

250V AC

250V AC

Rated impulse voltage

6000V (1.2/50us)

6000V (1.2/50us)

Dielectric strength

1500V AC, 1min

1500V AC, 1min

Clearance and creepage distance

In accordance with EN 60947-1

In accordance with EN 60947-1

Safety integrity level

SIL3

SIL3

Performance level

PLe

PLe

Category

Block Diagram of Safety Mat Safety Relay

Typical Applications of Safety Mat Safety Relay

CHENZHUstrives to provide high-quality products and services to meet the expectations of our customers and interested parties by delivering outstanding performance. We have special talents to research and develop automation and safetysystem. Indeed, automation and safety are our interface products' main characters.


Send product request

To: Shanghai Chenzhu Instrument Co., Ltd.
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

AC Power SPD
AC Power SPD ACSPDType 2 The ac voltage protectorfor AC unit is designed to prevent transient surge conditions. Large single surge events, such as lightning, c...
GS8500-EX Temperature Converter Intrinsic Safety Barrier
GS8500-EX Temperature Converter Intrinsic Safety Barrier Temperature input isolated barriers, converter potentiometer/RTD/TC signals in hazardous area into 0/4~20mA or 0/1~5V signals and output to safe ar...
CZ3000 Temperature Converter Signal Conditioner
CZ3000 Temperature Converter Signal Conditioner CZ3000 Temperature Signal Conditioner Thermal resistance type signal isolators,the two-wire or three-wire system resistance signal is converted in...
Safety Mat Safety Relay
Safety Mat Safety Relay Safety mat relaymodules provide a high level of fail-safe operation for critical processes and protection. This safety mat and multi-function contr...
Safety Relay
Safety Relay Automation direct safety relays are mainly applied to the safety control circuit, connecting the safety sensing elements and mechanical equipment m...
All supplier products

Same products

2rb 590-7ab26 Side Channel Blower/Low Noisy Packing Machines
2rb 590-7ab26 Side Channel Blower/Low Noisy Packing Machines Seller: Greentech Industry (Jinan) Co., Ltd The impellers in the G_series machines are mounted directly on the motor shaft for noncontact com...
2rb 530-7AV35 Regenerative Blower/Air Compressor/Side Channel Blower
2rb 530-7AV35 Regenerative Blower/Air Compressor/Side Channel Blower Seller: Greentech Industry (Jinan) Co., Ltd The impellers in the G_series machines are mounted directly on the motor shaft for noncontact com...
M8026 Roots Blower/Air Blower for Industrial and Transport Oxygen Supply
M8026 Roots Blower/Air Blower for Industrial and Transport Oxygen Supply Seller: Greentech Industry (Jinan) Co., Ltd Greentech International (Zhangqiu) Co., Ltdis the professional roots blower supplier. Series M Ro...
Side Channel Blower (2RB210 ring blower)
Side Channel Blower (2RB210 ring blower) Seller: Greentech Industry (Jinan) Co., Ltd Greentech International (Zhangqiu) Co., Ltd is the professional side channel blower supplier.The ...
Lz037b40 Maglev Turbo Blower/Energy Saving
Lz037b40 Maglev Turbo Blower/Energy Saving Seller: Greentech Industry (Jinan) Co., Ltd The impeller of magnetic suspension centrifugal fan is driven by direct connection between AL7075...