Safety Mat Safety Relay

Safety mat relaymodules provide a high level of fail-safe operation for critical processes and protection. This safety mat and multi-function controllers safety relay offer 2 or 4-wire safety mats/edges. Automatic reset and monitored manual reset are available.

The programmable safety relays support 3 safety output contacts (N/O) and 1 auxiliary output contacts (N/C) or 2NO+1NC+1SO or 2NO(t)+1NC(t).

Features & Advantages of Safety Mat Safety Relay

2-wire safety mats/edge

4-wire safety mats/edge

Automatic reset

Monitored manual reset

Parameter of Safety Mat Safety Relay

CZSR8301-3A1B

CZSR8301-3A1B(M)

CZSR8302-3A1B

CZSR8303-3A1B

Supply voltage

24V DC/AC

24V DC/AC

24V DC/AC

100V~230V AC

Voltage tolerance

-

Current consumption

≤90mA (24V DC) / ≤240mA (24V AC)

≤90mA (24V DC) / ≤240mA (24V AC)

≤90mA (24V DC) / ≤240mA (24V AC)

≤7 VA (220V AC)

Input current

≤50mA (24V DC)

≤50mA (24V DC)

≤10mA (24V DC)

≤10mA (220V AC)

Cable resistance

≤15Ω

≤15Ω

≤15Ω

≤15Ω

Input devices

Safety mats (4-wire)

Safety mats (4-wire)

Safety mats (4-wire)

Safety mats, safety edges (2 or 4-wire)

Number of contacts

3NO+1NC

3NO+1NC

3NO+1NC

Contact material

AgSnO2 + 0.2 µm Au

AgSnO2 + 0.2 µm Au

AgSnO2 + 0.2 µm Au

AgSnO2 + 0.2 µm Au

External contact fuse protection

10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC)

10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC)

10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC)

10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC)

Mechanical endurance of contacts

≥107

≥107

≥107

≥107

Utilisation category

In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V

In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V

In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V

In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V

Switch-on delay

≤300ms

≤150ms

≤300ms

≤300ms

Delay-on de-energisation

≤30ms

≤30ms

≤30ms

≤30ms

Recovery time

≤300ms

≤300ms

≤100ms

≤500ms

Supply short interruption

20ms

20ms

20ms

20ms

EMC

EN60947, EN61000-6-2, EN61000-6-4

EN60947, EN61000-6-2, EN61000-6-4

EN60947, EN61000-6-2, EN61000-6-4

EN60947, EN61000-6-2, EN61000-6-4

Vibration

Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm

Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm

Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm

Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm

Ambient temperature

-20℃~+60℃

-20℃~+60℃

-20℃~+60℃

-20℃~+60℃

Storage temperature

-40℃~+85℃

-40℃~+85℃

-40℃~+85℃

-40℃~+85℃

Relative humidity

10%~90%

10%~90%

10%~90%

10%~90%

Elevation

≤2000m

≤2000m

≤2000m

≤2000m

Overvoltage category

Pollution degree

2

2

2

2

Rated insulation voltage

250V AC

250V AC

250V AC

250V AC

Rated impulse voltage

6000V (1.2/50us)

6000V (1.2/50us)

6000V (1.2/50us)

6000V (1.2/50us)

Dielectric strength

1500V AC, 1min

1500V AC, 1min

1500V AC, 1min

1500V AC, 1min

Clearance and creepage distance

In accordance with EN 60947-1

In accordance with EN 60947-1

In accordance with EN 60947-1

In accordance with EN 60947-1

Safety integrity level

SIL3

SIL3

SIL3

SIL3

Performance level

PLe

PLe

PLe

PLe

Category

CZSR8302-2A1B1S

CZSR8302-2AT1BT1S

Supply voltage

24V DC/AC

24V DC/AC

Voltage tolerance

Current consumption

≤120mA (24V DC), ≤300mA (24V AC)

≤120mA (24V DC), ≤300mA (24V AC)

Input current

≤10mA (24V DC)

≤10mA (24V DC)

Cable resistance

≤15Ω

≤15Ω

Input devices

Safety mats, safety edges (2 or 4-wire)

Safety switches, Contact switches

Terminal resistance

Number of contacts

2NO+1NC+1SO

2NO(t)+1NC(t)

Contact material

AgSnO2 + 0.2 µm Au

AgSnO2 + 0.2 µm Au

External contact fuse protection

10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC)

10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC)

Mechanical endurance of contacts

≥107

≥107

Utilisation category

In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V

In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V

Semiconductor output data

Number of semi-output:1SODriving ability:20mA/24V DC

Number of semi-output:1SODriving ability:20mA/24V DC

Switch-on delay

≤300ms

≤300ms

Delay-on de-energisation

≤30ms(instantaneous)

≤30ms (instantaneous)0s, 0.5s, 1s, 2s, 3s, 5s(Deleted factory set as 5s)

Recovery time

≤100ms

≤100ms

Supply short interruption

20ms

20ms

EMC

EN60947, EN61000-6-2, EN61000-6-4

EN60947, EN61000-6-2, EN61000-6-4

Vibration

Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm

Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm

Ambient temperature

-20℃~+60℃

-20℃~+60℃

Storage temperature

-40℃~+85℃

-40℃~+85℃

Relative humidity

10%~90%

10%~90%

Elevation

≤2000m

≤2000m

Overvoltage category

Pollution degree

2

2

Rated insulation voltage

250V AC

250V AC

Rated impulse voltage

6000V (1.2/50us)

6000V (1.2/50us)

Dielectric strength

1500V AC, 1min

1500V AC, 1min

Clearance and creepage distance

In accordance with EN 60947-1

In accordance with EN 60947-1

Safety integrity level

SIL3

SIL3

Performance level

PLe

PLe

Category

Block Diagram of Safety Mat Safety Relay

Typical Applications of Safety Mat Safety Relay

CHENZHUstrives to provide high-quality products and services to meet the expectations of our customers and interested parties by delivering outstanding performance. We have special talents to research and develop automation and safetysystem. Indeed, automation and safety are our interface products' main characters.



Send product request

To: Shanghai Chenzhu Instrument Co., Ltd.
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Network SPD
Network SPD TheSPD networksurge protection device, also called ethernet cable surge protector, protects a data line, including computer network signals, commun...
Intrinsic Isolated Barrier
Intrinsic Isolated Barrier Intrinsic safety barrier instrumentand isolators use intrinsically safe explosion-proof and functional safety technologies and adopts various measu...
DO Signal (SIS) Input 24V DC 5A Safety Relay
DO Signal (SIS) Input 24V DC 5A Safety Relay These safety relay are suitable for the application of E-Stop button, safety gate and DO signal from SIS, with several contacts output. The emer...
Intrinsic Isolated Barrier
Intrinsic Isolated Barrier Intrinsic safety barriers and isolatorsuse intrinsically safe explosion-proof and functional safety technologies and adopts various measures such a...
Antennas And Feeders SPD
Antennas And Feeders SPD Antennas feeders SPD is used in the antenna feeder circuit of the radio communication station to suppress the induced lightning waves from the ante...
All supplier products

Same products

SPD for AC Power Supply
SPD for AC Power Supply Seller: Shenzhen Techwin Lightning Technologies Co., Ltd SPD for AC Power Supply is mainly applicable to the power distribution systems for Class I / II /...
Electric Chainsaw
Electric Chainsaw Seller: Zhejiang GuYueHu Industry&Trade Co.,Ltd. Suca battery electric chainsawis not only powerful but also good for the environment. The electri...
Matrix Body PDC Bit For Oil Well Drilling Hard Rock
Matrix Body PDC Bit For Oil Well Drilling Hard Rock Seller: Cangzhou Great Drill Bits Co.,Ltd. Overview of Matrix Body PDC Bit GM1605T Matrix body PDC bit GM 1605T is made by Tungsten carbide...
Matrix Body PDC Bit
Matrix Body PDC Bit Seller: Cangzhou Great Drill Bits Co.,Ltd. GREAT, as one of the professional drill bit manufacturers in China, we design and manufacture a w...
Longer Working Life Hybrid Drill Bits Improve Drilling Effeciency
Longer Working Life Hybrid Drill Bits Improve Drilling Effeciency Seller: Cangzhou Great Drill Bits Co.,Ltd. Overview of Hybrid Drill Bit Hybrid drill bits are compounded by the PDC fixed cutting and the r...