Safety Mat Safety Relay
Safety mat relaymodules provide a high level of fail-safe operation for critical processes and protection. This safety mat and multi-function controllers safety relay offer 2 or 4-wire safety mats/edges. Automatic reset and monitored manual reset are available.
The programmable safety relays support 3 safety output contacts (N/O) and 1 auxiliary output contacts (N/C) or 2NO+1NC+1SO or 2NO(t)+1NC(t).
Features & Advantages of Safety Mat Safety Relay
2-wire safety mats/edge
4-wire safety mats/edge
Automatic reset
Monitored manual reset
Parameter of Safety Mat Safety Relay
|
CZSR8301-3A1B |
CZSR8301-3A1B(M) |
CZSR8302-3A1B |
CZSR8303-3A1B |
|
|
Supply voltage |
24V DC/AC |
24V DC/AC |
24V DC/AC |
100V~230V AC |
|
Voltage tolerance |
- |
|||
|
Current consumption |
≤90mA (24V DC) / ≤240mA (24V AC) |
≤90mA (24V DC) / ≤240mA (24V AC) |
≤90mA (24V DC) / ≤240mA (24V AC) |
≤7 VA (220V AC) |
|
Input current |
≤50mA (24V DC) |
≤50mA (24V DC) |
≤10mA (24V DC) |
≤10mA (220V AC) |
|
Cable resistance |
≤15Ω |
≤15Ω |
≤15Ω |
≤15Ω |
|
Input devices |
Safety mats (4-wire) |
Safety mats (4-wire) |
Safety mats (4-wire) |
Safety mats, safety edges (2 or 4-wire) |
|
Number of contacts |
3NO+1NC |
3NO+1NC |
3NO+1NC |
|
|
Contact material |
AgSnO2 + 0.2 µm Au |
AgSnO2 + 0.2 µm Au |
AgSnO2 + 0.2 µm Au |
AgSnO2 + 0.2 µm Au |
|
External contact fuse protection |
10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC) |
10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC) |
10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC) |
10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC) |
|
Mechanical endurance of contacts |
≥107 |
≥107 |
≥107 |
≥107 |
|
Utilisation category |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
|
Switch-on delay |
≤300ms |
≤150ms |
≤300ms |
≤300ms |
|
Delay-on de-energisation |
≤30ms |
≤30ms |
≤30ms |
≤30ms |
|
Recovery time |
≤300ms |
≤300ms |
≤100ms |
≤500ms |
|
Supply short interruption |
20ms |
20ms |
20ms |
20ms |
|
EMC |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
|
Vibration |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
|
Ambient temperature |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
|
Storage temperature |
-40℃~+85℃ |
-40℃~+85℃ |
-40℃~+85℃ |
-40℃~+85℃ |
|
Relative humidity |
10%~90% |
10%~90% |
10%~90% |
10%~90% |
|
Elevation |
≤2000m |
≤2000m |
≤2000m |
≤2000m |
|
Overvoltage category |
Ⅲ |
Ⅲ |
Ⅲ |
Ⅲ |
|
Pollution degree |
2 |
2 |
2 |
2 |
|
Rated insulation voltage |
250V AC |
250V AC |
250V AC |
250V AC |
|
Rated impulse voltage |
6000V (1.2/50us) |
6000V (1.2/50us) |
6000V (1.2/50us) |
6000V (1.2/50us) |
|
Dielectric strength |
1500V AC, 1min |
1500V AC, 1min |
1500V AC, 1min |
1500V AC, 1min |
|
Clearance and creepage distance |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
|
Safety integrity level |
SIL3 |
SIL3 |
SIL3 |
SIL3 |
|
Performance level |
PLe |
PLe |
PLe |
PLe |
|
Category |
|
CZSR8302-2A1B1S |
CZSR8302-2AT1BT1S |
|
|
Supply voltage |
24V DC/AC |
24V DC/AC |
|
Voltage tolerance |
||
|
Current consumption |
≤120mA (24V DC), ≤300mA (24V AC) |
≤120mA (24V DC), ≤300mA (24V AC) |
|
Input current |
≤10mA (24V DC) |
≤10mA (24V DC) |
|
Cable resistance |
≤15Ω |
≤15Ω |
|
Input devices |
Safety mats, safety edges (2 or 4-wire) |
Safety switches, Contact switches |
|
Terminal resistance |
||
|
Number of contacts |
2NO+1NC+1SO |
2NO(t)+1NC(t) |
|
Contact material |
AgSnO2 + 0.2 µm Au |
AgSnO2 + 0.2 µm Au |
|
External contact fuse protection |
10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC) |
10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC) |
|
Mechanical endurance of contacts |
≥107 |
≥107 |
|
Utilisation category |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
|
Semiconductor output data |
Number of semi-output:1SODriving ability:20mA/24V DC |
Number of semi-output:1SODriving ability:20mA/24V DC |
|
Switch-on delay |
≤300ms |
≤300ms |
|
Delay-on de-energisation |
≤30ms(instantaneous) |
≤30ms (instantaneous)0s, 0.5s, 1s, 2s, 3s, 5s(Deleted factory set as 5s) |
|
Recovery time |
≤100ms |
≤100ms |
|
Supply short interruption |
20ms |
20ms |
|
EMC |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
|
Vibration |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
|
Ambient temperature |
-20℃~+60℃ |
-20℃~+60℃ |
|
Storage temperature |
-40℃~+85℃ |
-40℃~+85℃ |
|
Relative humidity |
10%~90% |
10%~90% |
|
Elevation |
≤2000m |
≤2000m |
|
Overvoltage category |
Ⅲ |
Ⅲ |
|
Pollution degree |
2 |
2 |
|
Rated insulation voltage |
250V AC |
250V AC |
|
Rated impulse voltage |
6000V (1.2/50us) |
6000V (1.2/50us) |
|
Dielectric strength |
1500V AC, 1min |
1500V AC, 1min |
|
Clearance and creepage distance |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
|
Safety integrity level |
SIL3 |
SIL3 |
|
Performance level |
PLe |
PLe |
|
Category |
Block Diagram of Safety Mat Safety Relay
Typical Applications of Safety Mat Safety Relay
CHENZHUstrives to provide high-quality products and services to meet the expectations of our customers and interested parties by delivering outstanding performance. We have special talents to research and develop automation and safetysystem. Indeed, automation and safety are our interface products' main characters.
Send product request
Other supplier products
| Intrinsic Isolated Barrier | Intrinsic Isolated Barrier Intrinsically safe electrical equipmentand isolators use intrinsically safe explosion-proof and functional safety techn... | |
| GS8500-EX Series Intrinsic Safety Barrier | GS8500-EX range functional safety isolated barriers are CHENZHU's hit products, which obtained the first IECEx, ATEX, DE TUV SIL, JP TIIS certifica... | |
| The Principle and Classification of Safety Barriers | China safety barrier is generally used in intrinsic safety systems. Intrinsic safety refers to system explosion-proof technology, which refers to t... | |
| The Working Principle and Classification of Surge Protector | Ⅰ. The surge protection device working principle Surge protection device is an indispensable device in lightning protection of electronic equipmen... | |
| Intrinsic Isolated Barrier | Intrinsic safety barriers and isolatorsuse intrinsically safe explosion-proof and functional safety technologies and adopts various measures such a... |
Same products
| Bolt Pull Test | Seller: Huanghua Tanrimine Metal Support Co. Ltd. | Bolt Pull Test Bolt Pull Test Introduction plays a critical role in assessing the performan... | |
| Split Set Mining Systems | Seller: Huanghua Tanrimine Metal Support Co. Ltd. | Split Set Mining Systems Friction Bolt Mining Systems are a type of rock reinforcement meth... | |
| Lz075b80 Maglev Turbo Blower | Seller: Greentech International (Zhangqiu) Co., Ltd | constituent:The impeller of magnetic suspension centrifugal fan is driven by direct connection be... | |
| Lz055b80 Maglev Turbo Blower/for Sintering Furnace in Sintering and Ignition Boosting | Seller: Greentech International (Zhangqiu) Co., Ltd | Using the leading ultra-high speed permanent magnet synchronous motor technology, high-speed oper... | |
| Lz110b80 Maglev Turbo Blower/Fan/Energy Saving/Blower | Seller: Greentech International (Zhangqiu) Co., Ltd | Using the leading ultra-high speed permanent magnet synchronous motor technology, high-speed oper... |