5-600A 0.333V Split Current Transformer for Electrical Motor and HVAC
0.5-600A 0.333V Transformer Split with ETL
TIANJIN GREWIN TECHNOLOGY CO.,LTD. | ||||||||||
GWCTSA series split core current transformer | ||||||||||
Part number | Rated input(A) | Second output(V) | Accuracy class | Limit primary current(A) | Accuracy class | Frequency(Hz) | OutlineDimensions ID-L-W-H(mm) | Unit weight | Turn ratio | Output cable |
GWCTSA005 | 51015 | 0.333 | 1.0 3.0 | - | - | 50-400 | 5.0-25.0-22.5-34.5 | 30g | 3000:1 | wire(1m) |
GWCTSA010 | 5,10,20,50,75 | 0.333 | 1.0 3.0 | 120 | 5P 10P | 50-400 | 10-29.4-26.4-41.7 | 50g | 3000:1 | wire(1m) |
GWCTSA016 | 75,100,150 | 0.333 | 0.5 1.0 | 300 | 5P 10P | 50-400 | 16-36.9-39.2-52.9 | 100g | 3000:1 | wire(1m) |
GWCTSA024 | 100,150,200,250 | 0.333 | 0.5 1.0 | 540 | 5P 10P | 50-400 | 24-51.2-47-70.2 | 250g | 3000:1 | wire(1m) |
GWCTSA035 | 200,300,400,600 | 0.333 | 0.5 1.0 | 600 | 5P 10P | 50-400 | 35-65.8-51.2-83.5 | 400g | 3000:1 | wire(1m) |
GWCTSA Series Split Core Current Sensor (Specifications) |
|
Rated Primary current |
5-600A |
Rated Secondary current |
0.333V-3.53V |
Rated load |
1, 2.5, 5.0, 10, 30VA |
Accuracy |
0.5, 1.0, 3.0 Class |
Rated Short-time thermal current (Ith) |
20In |
Rated Dynamic current (Idyn) |
2.5Ith |
Case Material |
UL flame retardant rating 94-V0 |
Highest Voltage for Equipment Um (rms) |
720 Vac |
Rated Power-Frequency Withstand Voltage(rms) |
3,000 Vac |
Frequency Range: |
50/60Hz |
Operating Temperature |
-15ºC to 50ºC |
Standard |
IEC 60044-1 |
Accessories |
Supplied with feet for base mounting if required |
Certification |
RoHS compliant CE&ETL approved |
GWCTSA Series Split Core Current Sensor(Features) |
Low cost |
5 standard sizes |
Split core design, safer, easier installation, and portable |
GWCTSA Series Split Core Current Sensor(Applications) |
Measures AC current flow to electric motors, lighting, air condition equipment, etc. |
Compatible with HVACtemperature control, power management, building |
The GREWIN CTSA series of split core ct style current sensors are designed for fast and easy installation.The split core design permits non-contactcurrent measurements through magnetic field induction without disconnecting cables or busbar circuits for CT installation. This method permits asafer, easier and portable current measurement.
0.333-3.53V rated secondary output split core current transformer :
Model No 1:GWCTSA010
Ratio :3000:1
Rated input: 5A 10A 20A 50A 75A
Accuracy class: 1.0s3.0s
Rated primary current :120A
Protection: 5times protection ,10 times protection like 25A 50A 100A 200A 250A 385A 500A 750A
Model No.2 :GWCTSA016
Ratio :3000:1
Rated input: 75A 100A 150A
Accuracy class: 0.5 1.0S
Rated accuracy limit primary current: 300A
Protection :5 times Protection, 10 times protection
Model No. 3:GWCTSA024
Ratio :3000:1
Rated input: 100A 150A 200A 250A
Accuracy class: 0.5 1.0S
Rated accuracy limit primary current: 540A
Protection :5 times Protection, 10 times protection
Model No.4:GWCTSA035
Rated input: 200A 300A 400A 600A
Accuracy class: 0.5 1.0S
Rated accuracy limit primary current: 600A
Protection :5 times Protection, 10 times protection
Frequency: 50--400Hz
CONTACT INFO:
TIANJIN GREWIN TECHNOLOGY CO.,LTD
Add:Meinian Plaza.No.16 Dongting Road,Hexi Distr,Tianjin,China .
Amy
Tel:
Web:
Mobile:
Send product request
Other supplier products
Open loop current sensor | Features: The output value can be customized. This produce has core through structure. No insertion loss. Lower power consumption Wide measuring r... | |
GWSCCT661Rated Input 0.5-630A Output 0-500mA/0.333V split core toroidal current transformer for Current measurement | Features lThe structure of the self-locking, safe, easy to install, portable lWide inner window, allowing clamping of big cables or bus-bars lWid... | |
0.2 Accuracy Temperature Measurement Ce RoHS Approved Non-Contact Digital Infrared Clinical Thermometer for Kitchen Cooking | Ce RoHS Non Contact Forehead Thermometer Infrared Thermometerfor Body or Object Temperature Baby Ear Model GW1 Products keywords Factory... | |
5-600A 0.333V Split Current Transformer for Electrical Motor and HVAC | 0.5-600A 0.333V Transformer Split with ETL TIANJIN GREWIN TECHNOLOGY CO.,LTD. GWCTSA series split core current transformer Part ... | |
IEC60076 50Hz~400Hz clamp-on current transformer for electrical wiring and equipment | Tianjin Grewin Technology Co.,Ltd. Web: Mail: |
Same products
S11-M Power Transformer | Seller: Bokong Electric Co., Ltd | S11-M Product Description S11-M a new generation of low noise and low loss transformer devel... | |
Compact Transformer | Seller: Shaanxi Hanzhong Transformer Co., ltd | As a leading compact transformer substationmanufacturer and box type substation supplier, SEC com... | |
Combined Pad Mounted Substation | Seller: Shaanxi Hanzhong Transformer Co., ltd | Combined Pad Mounted Substation The ZBG series America Housing Type Transformer are researched a... | |
Amorphous Alloy Dry Type Transformer | Seller: Shaanxi Hanzhong Transformer Co., ltd | SCBH15eres amorphous alloy dry type transformerpertorms well not only for its excellent propertie... | |
35KV Power Transformer | Seller: Shaanxi Hanzhong Transformer Co., ltd | This 35 KV transformerhas the characteristics of high efficiency and low loss, can save a lot of ... |